Multi-Criteria Detectors
System Sensor 2WTR-B 2-Wire Photoelectric Thermal Smoke Detector
System sensor·SKU: 2WTR-B
Indicative Price
Excluding local taxes and shipping.
The 2WTR-B is a 2-wire, photoelectric i3 smoke detector with thermal sensor and Form C relay. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for
infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.
Description
The 2WTR-B is a 2-wire, photoelectric i3 smoke detector with thermal sensor and Form C relay. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for pre-wiring the device. To complete the installation, the i3 detector plugs into its base with a simple Stop-Drop N Lock action.
To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready panel, 2wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds.
i3 has red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. When in alarm, i3 sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal.
Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm when the thermal sensor is activated.
UPC: 783863019975
Also known as: BK-2WTRB, 2WTRB
To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready panel, 2wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds.
i3 has red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. When in alarm, i3 sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal.
Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm when the thermal sensor is activated.
UPC: 783863019975
Also known as: BK-2WTRB, 2WTRB
Technical Specifications:
|
- Isolated thermal sensor
- Removable cover and chamber
- Flexible mounting options
- In-line terminals
- Plug-in design (base included)
- Form C relay
- 85 dB sounder
- Dual-color LEDs
- Simplified sensitivity measurement
- Drift compensation and smoothing algorithms
- Remote maintenance signaling
- Stop-Drop N Lock attachment to the base
Technical Specifications
| Alarm Current | 130mA max., limited by panel |
|---|---|
| Auxiliary Contact | Form C |
| Auxiliary Contact Ratings | 2A @ 30V AC/DC |
| Brand | System Sensor |
| Detection | Photoelectric |
| Dimensions | 2.0" (51mm) H x 5.3" (127mm) Dia. |
| Freeze Trouble | 41F (5C) |
| Heat Sensor | 135F (57.2C) fixed |
| Humidity Range | 0% to 95% RH, noncondensing |
| Manufacturer Part Number | 2WTR-B |
| Maximum Ripple Voltage | 30% of applied voltage (peak to peak) |
| Operating Voltage | 12/24 V non-polarized nominal, 8.5 min. to 35 max. |
| Sensitivity | 2.5%/ft. nominal |
| Standby Current | 50 A max. avg., 100 A peak |
| Temperature Range | 32 to 100F (0 to 37.8C) |
| UPC | 783863019975 |
| Weight | 7.1 oz. (200 g) |
| Wiring | 2-wire |
| Wiring Gauge | 14-22 AWG |
Documents & Technical Downloads
Related Products
View Cataloguearrow_forward
Advanced AXIS-OHX Axis EN Multi-Sensor Detector W Isolator
Indicative Price
from

Advanced AXIS-OH Axis EN Multi-sensor Detector
Indicative Price
from

Cooper FXN922 Conventional Multi-Mode Detector
Indicative Price
from

Mircom MIX-2351TAP (Smoke and Thermal Sensor)
Indicative Price
from