Fire Resistant Cables
Context Plus 100 mtrs Reel ‘XP PREMIUM’ fire resistant cable 2 core, 1.5mm square solid core, Red, LPCB approved
Context Plus·SKU: FPX-215DR
• Made of 2 solid copper conductor cores 1.5mm² each with 0.8mm drain wire, the cable construction is shown in the photo below • All Context Plus fire resistant cables are approved & certified by LPCB to meet current British and European fire test standards plus the additional life safety requiremen
Request a quoteDescription
All the Context Plus XP Premium fire-resistant cables are certified and approved to the following British and European Standards:
| Ref | Description |
|---|---|
| BS 6387 C | To comply with this standard the cable must retain continuity for 180 minutes under fire condition at 950 degrees C |
| BS 6387 W | To comply with this standard the cable must retain continuity for 30 minutes under fire condition at 650 degrees C with water spray applied during the final 15 minutes |
| BS 6387 Z | To comply with this standard the cable must retain continuity for 15 minutes under fire condition at 950 degrees C with a mechanical shock applied every 30 seconds during the full 15 minutes test |
| BS EN 50200 PH30 | To comply with this standard a cable must retain continuity for 30 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 30 minutes test |
| BS EN 60332 | To comply with this Flame Retardancy Standard a cable must self-extinguish leaving the upper cable sheath unaffected when a flame of 1kw of caloric power is applied for 30 seconds to it. This then demonstrates that the cable does not propagate fire. |
| BS EN 60754-1:2014 | To comply with this Zero Halogen standard a cable must have an Emission of less than 0.5% of corrosive & acid gas when under fire condition |
| EN 61034-2:2005:+A1:2013 | To comply with this Low Smoke standard a cable must be Meeting at least 60% for residual light transmission when under fire condition |
| BS EN 50200 PH60 | To comply with a cable must retain continuity for 60 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 60 minutes test |
| BS EN 50200 PH120 | To comply with a cable must retain continuity for 120 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 120 minutes test |
| BS EN 50200 + Annex E 30 mins | To comply with this standard the cable must retain continuity for 30 Minutes under fire conditions at 830 degrees C with a mechanical shock applied every 5 minutes during the full 30 minutes and for final 15 minutes water spray is applied |
Sales Leaflet
View LeafletTechnical Specifications
| BS 6387 C | To comply with this standard the cable must retain continuity for 180 minutes under fire condition at 950 degrees C |
|---|---|
| BS 6387 W | To comply with this standard the cable must retain continuity for 30 minutes under fire condition at 650 degrees C with water spray applied during the final 15 minutes |
| BS 6387 Z | To comply with this standard the cable must retain continuity for 15 minutes under fire condition at 950 degrees C with a mechanical shock applied every 30 seconds during the full 15 minutes test |
| BS EN 50200 PH120 | To comply with a cable must retain continuity for 120 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 120 minutes test |
| BS EN 50200 PH30 | To comply with this standard a cable must retain continuity for 30 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 30 minutes test |
| BS EN 50200 PH60 | To comply with a cable must retain continuity for 60 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 60 minutes test |
| BS EN 60754-1 | 2014 |
| BS EN 60754-1:2014 | To comply with this Zero Halogen standard a cable must have an Emission of less than 0.5% of corrosive & acid gas when under fire condition |
| Cable length | 100 mtrs Reel |
| Conductor cross-section | 1.5mm square |
| Core count | 2 core |
| EN 61034-2 | 2005:+A1:2013 |
| EN 61034-2:2005:+A1:2013 | To comply with this Low Smoke standard a cable must be Meeting at least 60% for residual light transmission when under fire condition |