Context Plus 100 mtrs Reel ‘HP HIGH PERFORMANCE’ fire resistant cable 2 core, 1.5mm sq solid core, Red, meets BS5839 Pt1 2002 26.2d – 26.2d. LPCB approved
Fire Resistant Cables

Context Plus 100 mtrs Reel ‘HP HIGH PERFORMANCE’ fire resistant cable 2 core, 1.5mm sq solid core, Red, meets BS5839 Pt1 2002 26.2d – 26.2d. LPCB approved

Context Plus·SKU: FPS-215ER

Made of 2 solid copper conductor cores 5mm² each with an additional Earth core called a CPC Circuit Protection Core, the cable construction is shown in the photo below All Context Plus fire resistant cables are approved & certified by LPCB to meet current British and European fire test standards plu

Request a quote

Description

All the Context Plus HP High Performance fire-resistant cables are certified and approved to the following British and European Standards:

Ref Description
BS 6387 C To comply with this standard the cable must retain continuity for 180 minutes under fire condition at 950 degrees C
BS 6387 W To comply with this standard the cable must retain continuity for 30 minutes under fire condition at 650 degrees C with water spray applied during the final 15 minutes
BS 6387 Z To comply with this standard the cable must retain continuity for 15 minutes under fire condition at 950 degrees C with a mechanical shock applied every 30 seconds during the full 15 minutes test
BS EN 50200 PH30 To comply with this standard a cable must retain continuity for 30 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 30 minutes test
BS EN 60332 To comply with this Flame Retardancy Standard a cable must self-extinguish leaving the upper cable sheath unaffected when a flame of 1kw of caloric power is applied for 30 seconds to it. This then demonstrates that the cable does not propagate fire.
BS EN 60754-1:2014 To comply with this Zero Halogen standard a cable must have an Emission of less than 0.5% of corrosive & acid gas when under fire condition
EN 61034-2:2005:+A1:2013 To comply with this Low Smoke standard a cable must be Meeting at least 60% for residual light transmission when under fire condition
BS EN 50200 PH60 To comply with a cable must retain continuity for 60 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 60 minutes test
BS EN 50200 PH120 To comply with a cable must retain continuity for 120 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 120 minutes test
BS EN 50200 + Annex E 30 mins To comply with this standard the cable must retain continuity for 30 Minutes under fire conditions at 830 degrees C with a mechanical shock applied every 5 minutes during the full 30 minutes and for final 15 minutes water spray is applied
BS 7629-1 To comply with this standard the fire cable must be 300/500 Volts rated and must have low emission of smoke and corrosive (Halogen) gases when affected by fire.
BS 8519:2010 Category 1 To meet this standard a cable must demonstrate that its level of circuit integrity (Fire Survival of 30 minutes) is not compromised by other components of the whole electrical distribution system, including cable glands, terminations, joints and cable support systems
BS 5839-1:2013 Clause 26.2d ‘Standard 60’ Fire Cable To comply with this standard the fire must be tested to comply with all the standards described above: BS EN 50200: 2006 + Annex E 30 mins , BS EN 50200: 2006 PH30, BS 7629-1:2008, BS 6387: 1994 C, W & Z, BS EN 50267-2-1:1999, BS EN 61034-2:2005

All the Context Plus HP High Performance fire-resistant cables are certified and approved to the following British and European Standards:

Ref Description
BS 6387 C To comply with this standard the cable must retain continuity for 180 minutes under fire condition at 950 degrees C
BS 6387 W To comply with this standard the cable must retain continuity for 30 minutes under fire condition at 650 degrees C with water spray applied during the final 15 minutes
BS 6387 Z To comply with this standard the cable must retain continuity for 15 minutes under fire condition at 950 degrees C with a mechanical shock applied every 30 seconds during the full 15 minutes test
BS EN 50200 PH30 To comply with this standard a cable must retain continuity for 30 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 30 minutes test
BS EN 60332 To comply with this Flame Retardancy Standard a cable must self-extinguish leaving the upper cable sheath unaffected when a flame of 1kw of caloric power is applied for 30 seconds to it. This then demonstrates that the cable does not propagate fire.
BS EN 60754-1:2014 To comply with this Zero Halogen standard a cable must have an Emission of less than 0.5% of corrosive & acid gas when under fire condition
EN 61034-2:2005:+A1:2013 To comply with this Low Smoke standard a cable must be Meeting at least 60% for residual light transmission when under fire condition
BS EN 50200 PH60 To comply with a cable must retain continuity for 60 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 60 minutes test
BS EN 50200 PH120 To comply with a cable must retain continuity for 120 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 120 minutes test
BS EN 50200 + Annex E 30 mins To comply with this standard the cable must retain continuity for 30 Minutes under fire conditions at 830 degrees C with a mechanical shock applied every 5 minutes during the full 30 minutes and for final 15 minutes water spray is applied
BS 7629-1 To comply with this standard the fire cable must be 300/500 Volts rated and must have low emission of smoke and corrosive (Halogen) gases when affected by fire.
BS 8519:2010 Category 1 To meet this standard a cable must demonstrate that its level of circuit integrity (Fire Survival of 30 minutes) is not compromised by other components of the whole electrical distribution system, including cable glands, terminations, joints and cable support systems
BS 5839-1:2013 Clause 26.2d 'Standard 60' Fire Cable To comply with this standard the fire must be tested to comply with all the standards described above: BS EN 50200: 2006 + Annex E 30 mins , BS EN 50200: 2006 PH30, BS 7629-1:2008, BS 6387: 1994 C, W & Z, BS EN 50267-2-1:1999, BS EN 61034-2:2005

Sales Leaflet

View Leaflet

Official manufacturer product information

Technical Specifications

BS 5839-12013 Clause 26.2d ‘Standard 60’ Fire Cable
BS 6387 CTo comply with this standard the cable must retain continuity for 180 minutes under fire condition at 950 degrees C
BS 6387 WTo comply with this standard the cable must retain continuity for 30 minutes under fire condition at 650 degrees C with water spray applied during the final 15 minutes
BS 6387 ZTo comply with this standard the cable must retain continuity for 15 minutes under fire condition at 950 degrees C with a mechanical shock applied every 30 seconds during the full 15 minutes test
BS 7629-1To comply with this standard the fire cable must be 300/500 Volts rated and must have low emission of smoke and corrosive (Halogen) gases when affected by fire.
BS 85192010 Category 1
BS EN 50200 PH120To comply with a cable must retain continuity for 120 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 120 minutes test
BS EN 50200 PH30To comply with this standard a cable must retain continuity for 30 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 30 minutes test
BS EN 50200 PH60To comply with a cable must retain continuity for 60 minutes under fire condition at 830 degrees C with a mechanical shock applied every 5 minutes during the full 60 minutes test
BS EN 60754-12014
BS EN 60754-1:2014To comply with this Zero Halogen standard a cable must have an Emission of less than 0.5% of corrosive & acid gas when under fire condition
Cable length100 mtrs Reel
Conductor cross-section1.5mm sq
Core count2 core
EN 61034-22005:+A1:2013
EN 61034-2:2005:+A1:2013To comply with this Low Smoke standard a cable must be Meeting at least 60% for residual light transmission when under fire condition