Apollo 55000-845APO XP95 Zone Monitor Module – Isolating
The XP95 Zone Monitor Module is used to power and control a zone of up to 20 Apollo Series 65, Orbis or equivalent fire detectors and report their status to the fire control panel.
Request a quoteDescription
The XP95 Zone Monitor Module is used to power and control a zone of up to 20 Apollo Series 65, Orbis or equivalent fire detectors and report their status to the fire control panel.
- EN 54-17 & EN 54-18 Certified
- Allows conventional detection zones to be easily added to addressable systems
- Suitable for semi flush or surface mounting
- XP95, Discovery compatible
Technical Specifications
| Conformance - Approvals | VdS, FG, LPCB, CPR |
|---|---|
| Electrical - Maximum power-up time | 150ms |
| Electrical - Power-up surge current | 3.5mA |
| Electrical - Protocol voltage | 5 to 9V peak to peak |
| Electrical - Protocol voltage (max) | 9V |
| Electrical - Protocol voltage (min) | 5V |
| Electrical - Stabilization time on power up | 4s |
| Electrical - Supply voltage (max) | 28V dc |
| Electrical - Supply voltage (min) | 17V dc |
| Electrical - Supply voltage (Vmin-Vmax) | 17 to 28V dc |
| Environmental - Humidity | 0% to 95% (no condensation or icing) |
| Environmental - Humidity (max) | 95%, RH |
| Environmental - Humidity (min) | 0%, RH |
| Environmental - Humidity Note | no condensation or icing |
| Environmental - IP rating Value | IP54 |
| Environmental - Operating temperature | -20 to 70°C / -4 to 158°F |
| Environmental - Operating temperature (max) | 70°C / 158°F |
| Environmental - Operating temperature (min) | -20°C / -4°F |
| General - Warranty | 10 year |
| Mechanical - Colour | White |
| Mechanical - Materials housing | Polycarbonate |
| Mechanical - Product depth | 48mm / 1.89in |
| Mechanical - Product length | 90mm / 3.54in |
| Mechanical - Product width | 150mm / 5.91in |
| Mechanical - Weight | 230g |
Documents & Technical Downloads
PP2101 XP95 Zone Monitor with Isolator
Datasheet
PP2090 Short-Circuit Isolation Datasheet
Datasheet
Zone Monitor BIM Files
BIM
Zone Monitor BIM Files
BIM
Zone Monitor Installation Guide
Guide
FG – Forsikringsselskapenes Godkjennelsesnevnd
Certificate
CPR – Certificate of Constancy of Performance
Certificate
CPR -UKCA Certificate of Constancy of Performance
Certificate
VdS – Verband der Schadenversicherer
Certificate
LPCB – Loss Prevention Certification Board Certificate
Certificate
DoP – Declaration of Performance
Certificate
DE – DoP - Declaration of Performance
Certificate
DoP – UKCA Declaration of Performance
Certificate
EMC Directive 2014//30/EU_RoHS Directive 2011/65/EU_2015/863/EU
Certificate