System Sensor D4240 4-Wire Photoelectric Low-Flow Smoke Detector
Smoke Detectors

System Sensor D4240 4-Wire Photoelectric Low-Flow Smoke Detector

System sensor·SKU: D4240

Indicative Price

Excluding local taxes and shipping.

The InnovairFlex D4240 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit operates in airflow speeds of 100 to 4,000 feet per minute, temperatures of 4F to 158F, and a humidity r

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The InnovairFlex D4240 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit operates in airflow speeds of 100 to 4,000 feet per minute, temperatures of 4F to 158F, and a humidity range of 0 to 95 percent (non-condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance.

The InnovairFlex housing provides ample wiring space, a -inch conduit knockout, and built-in short-circuit protection to prevent damage to sensitive components during installation. High-contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4240 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, enabling the fire location to be pinpointed.

An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field-selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories.

UPC: 783863042362
Also known as: BK-D4240

Technical Specifications:
  • Wiring: 4-wire
  • Voltage Range: 20-29 VDC; 24 VAC 50-60 Hz; 240 VAC 50-60 Hz
  • Storage Temperature: -22F to 158F (-30C to 70C)
  • Standby Current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz
  • Shipping Weight: 2.5 lbs. (1.14 kg)
  • Reset Voltage: 3.0 VDC min.; 2.0 VAC min.; 10 VAC min.
  • Reset Time w RTS451: 0.03 to 0.3 sec.
  • Reset Time by Power Down: 0.6 sec. max.
  • Power Up Time: 35 sec. max.
  • Power Supply Voltage: 20-29 VDC; 24 VAC 50-60 Hz; 240 VAC 50-60 Hz
  • Operating Temperature Range: -4F to 158F (-20C to 70C)
  • Operating Humidity Range: 0% to 95% relative humidity non-condensing
  • Input Capacitance: 270 F max.
  • Dimensions: Rectangular: 14.38 in (37 cm) L; 5 in (12.74 cm) W; 2.5 in (6.36 cm) D; Square: 7.75 in (19.7 cm) L; 9 in (22.9 cm) W; 2.5 in (6.36 cm) D
  • Alarm Response Time: 15 sec.
  • Alarm Initiation Contacts: 2.0A @ 30 VDC (resistive)
  • Alarm Current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz
  • Alarm Auxiliary Contacts DPDT: 10A @ 30 VDC (resistive); 10A @ 250 VAC (resistive); HP @ 240 VAC ; HP @ 120 VAC
  • Air Duct Velocity: 100 to 4000 ft./min. (0.5 to 20.32 m/sec)


  • Backward compatibility with existing Innovair products, including remote accessories
  • Plug-in sensor offers superb false alarm immunity and the latest sensor technology
  • Versatile mounting options: square or rectangular configuration
  • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)
  • Photoelectric, integrated low-flow technology
  • 24 VAC/DC or 240 VAC
  • Two DPDT Form-C relay contacts
  • Field-selectable settings for configuring the detector
  • Built-in short-circuit protection from operator wiring errors
  • New high-contrast terminal designations
  • Patented interconnect feature for multi-fan shutdown
  • One easy-access Test/Reset button and improved LED status
  • Increased wiring space with a newly added -inch conduit knockout
  • Broad ranges for operating temperature (4F to 158F) and humidity (0% to 95% non-condensing)
  • Patented sampling tube installs from the front or back of the detector with no tools required

Supplier product information

Technical Specifications

Air Duct Velocity100 to 4000 ft./min. (0.5 to 20.32 m/sec)
Alarm Auxiliary Contacts DPDT10A @ 30 VDC (resistive); 10A @ 250 VAC (resistive); HP @ 240 VAC ; HP @ 120 VAC
Alarm Current65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz
Alarm Initiation Contacts2.0A @ 30 VDC (resistive)
Alarm Response Time15 sec.
BrandSystem Sensor
DimensionsRectangular: 14.38 in (37 cm) L; 5 in (12.74 cm) W; 2.5 in (6.36 cm) D; Square: 7.75 in (19.7 cm) L; 9 in (22.9 cm) W; 2.5 in (6.36 cm) D
Input Capacitance270 F max.
Manufacturer Part NumberD4240
Operating Humidity Range0% to 95% relative humidity non-condensing
Operating Temperature Range-4F to 158F (-20C to 70C)
Power Supply Voltage20-29 VDC; 24 VAC 50-60 Hz; 240 VAC 50-60 Hz
Power Up Time35 sec. max.
Reset Time by Power Down0.6 sec. max.
Reset Time w RTS4510.03 to 0.3 sec.
Reset Voltage3.0 VDC min.; 2.0 VAC min.; 10 VAC min.
Shipping Weight2.5 lbs. (1.14 kg)
Standby Current21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz
Storage Temperature-22F to 158F (-30C to 70C)
UPC783863042362
Versatile mounting optionssquare or rectangular configuration
Voltage Range20-29 VDC; 24 VAC 50-60 Hz; 240 VAC 50-60 Hz
Wiring4-wire

Documents & Technical Downloads

Context Plus Smoke detector built in sounder

Context Plus Smoke detector built in sounder

Indicative Price

from

Simplex 4098-9714 Photoelectric Smoke Detector

Simplex 4098-9714 Photoelectric Smoke Detector

Indicative Price

from

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Indicative Price

from