System Sensor D2 2-Wire Photoelectric Duct Smoke Detector
Duct Smoke Detectors

System Sensor D2 2-Wire Photoelectric Duct Smoke Detector

System sensor·SKU: D2

Indicative Price

Excluding local taxes and shipping.

The SYSTEM-SENSOR-D2 2-wire photoelectric duct smoke detector senses airflow speeds ranging from 100 to 4,000 feet per minute with proven System Sensor precision. The enhancements built into the D2 improve false alarm immunity (with plug-in sensor head); broaden operating temperature (4F to 158F) an

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The SYSTEM-SENSOR-D2 2-wire photoelectric duct smoke detector senses airflow speeds ranging from 100 to 4,000 feet per minute with proven System Sensor precision.

The enhancements built into the D2 improve false alarm immunity (with plug-in sensor head); broaden operating temperature (4F to 158F) and humidity (0 to 95 percent noncondensing) ranges; while simplifying installation and maintenance. These advance features can detect smoke even in the harshest duct applications.

The D2 duct smoke detector has signals to indicate trouble and maintenance conditions. Additionally, a cover tamper feature is incorporated to indicate a trouble condition for removed or improperly installed sensor cover.

The D2 eatures a pivoting housing that fits various applications: both square and rectangular footprints mount to round or rectangular duct work.

UPC: 783863034664
Also known as: BK-D2

Technical Specifications:
  • Max. alarm current: 130 mA
  • Max. standby current: 60 µA (average)
  • Peak standby current: 120µA
  • Current Requirements: (Using No Accessories)
  • Sensitivity Test: See detector label
  • Alarm response time: 15 sec.
  • Power up time: 35 sec. max.
  • Reset time: (by power down) 0.3 sec. max.
  • Reset time: (with RTS451) 0.03 to 0.3 sec.
  • Reset voltage: 2.5 VDC min.
  • Input capacitance: 0.1 µF max.
  • Power supply voltage: 8.5-35 VDC
  • Air Duct Velocity: 100 to 4000 ft/min (0.5 to 20.32 m/sec)
  • Weight: 1.8 lb (0.82 kg)
  • Square Dimensions: 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth
  • Rectangular Dimensions: 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.36 cm) Depth


  • Superb false alarm immunity with the latest sensor technology
  • Plug-in sensor
  • Versatile mounting options in square or rectangular configuration with modular construction
  • (0.5 m/s to 20.32 m/sec)
  • Air velocity rating from 100 ft/min to 4,000 ft/min
  • Photoelectric, integrated low-flow technology
  • 24 VDC
  • Patented sampling tube installs from front or back of the detector with no tools required
  • A cover tamper feature to indicate a trouble condition for removed or improperly installed sensor cover
  • Increased wiring space with a newly added ¾ inch conduit knockout
  • Improved LED status
  • Backward compatibility with existing Innovair products, including remote accessories
  • Broader ranges for operating temperature (−4°F to 158°F) and humidity (0% to 95% non-condensing)

Supplier product information

Technical Specifications

Air Duct Velocity100 to 4000 ft/min (0.5 to 20.32 m/sec)
Alarm response time15 sec.
BrandSystem Sensor
Current Requirements(Using No Accessories)
Input capacitance0.1 µF max.
Manufacturer Part NumberD2
Max. alarm current130 mA
Max. standby current60 µA (average)
Peak standby current120µA
Power supply voltage8.5-35 VDC
Power up time35 sec. max.
Rectangular Dimensions14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.36 cm) Depth
Reset time(with RTS451) 0.03 to 0.3 sec.
Reset voltage2.5 VDC min.
Sensitivity TestSee detector label
Square Dimensions7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth
UPC783863034664
Weight1.8 lb (0.82 kg)