System Sensor 4WITAR-B 4-Wire Photoelectric Smoke Detector
System sensor·SKU: 4WITAR-B
Indicative Price
Excluding local taxes and shipping.
The 4WITAR-B is a 4-wire, photoelectric i3 smoke detector with isolated thermal sensor, built-in sounder, and Form C relay. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting option
infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.
Description
The 4WITAR-B is a 4-wire, photoelectric i3 smoke detector with isolated thermal sensor, built-in sounder, and Form C relay. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for pre-wiring the device. To complete the installation, the i3 detector plugs into its base with a simple Stop-Drop N Lock action.
To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready panel, 2wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds.
i3 has red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. When in alarm, i3 sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal.
Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm when the thermal sensor is activated.
UPC: 783863020018
Also known as: BK-4WITARB, 4WITARB
To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready panel, 2wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds.
i3 has red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. When in alarm, i3 sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal.
Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm when the thermal sensor is activated.
UPC: 783863020018
Also known as: BK-4WITARB, 4WITARB
Technical Specifications:
|
- Drift compensation and smoothing algorithms
- Dual-color LEDs
- 85 dB sounder
- Form C relay
- Isolated thermal sensor
- Plug-in design (base included)
- In-line terminals
- Flexible mounting options
- Stop-Drop N Lock attachment to the base
- Removable cover and chamber
- Remote maintenance signaling
- Simplified sensitivity measurement
Technical Specifications
| Alarm Contact Ratings | 0.5A @ 30 VAC/DC |
|---|---|
| Alarm Current | 50mA max. |
| Auxiliary Contact | Form C |
| Auxiliary Contact Ratings | 2A @ 30V AC/DC |
| Brand | System Sensor |
| Detection | Photoelectric |
| Dimensions | 2.0" (51mm) H x 5.3" (127mm) Dia. |
| Freeze Trouble | 41F (5C) |
| Heat Sensor | Isolated - 135F (57.2C) fixed |
| Humidity Range | 0% to 95% RH, noncondensing |
| Manufacturer Part Number | 4WITAR-B |
| Maximum Ripple Voltage | 30% of applied voltage (peak to peak) |
| Operating Voltage | 12/24 V non-polarized nominal, 10 min. to 35 max. |
| Sensitivity | 2.5%/ft. nominal |
| Standby Current | 50 A max. avg. |
| Temperature Range | 32 to 100F (0 to 37.8C) |
| UPC | 783863020018 |
| Weight | 7.1 oz. (200 g) |
| Wiring | 4-wire |
| Wiring Gauge | 14-22 AWG |