Silent Knight SK-4 Four Zone Conventional Fire Alarm Control Panel
Conventional Fire Alarm Panels

Silent Knight SK-4 Four Zone Conventional Fire Alarm Control Panel

Silent Knight·SKU: SK-4

Indicative Price

Excluding local taxes and shipping.

The SILENT-KNIGHT-SK-4 is a four-zone, conventional 120 VAC fire alarm control panel that provides reliable fire signaling protection for small- to medium-sized commercial, industrial, and institutional buildings. The SK-4 is also compatible with conventional input devices such as two- and four-wire

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The SILENT-KNIGHT-SK-4 is a four-zone, conventional 120 VAC fire alarm control panel that provides reliable fire signaling protection for small- to medium-sized commercial, industrial, and institutional buildings.

The SK-4 is also compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices.

UPC: 783008107598
Also known as: SK-SK4, SK4

Technical Specifications:
  • Cabinet Door: 14.677" W x 15.342" H x 0.375" D (37.28 W x 38.97 H x 0.95 D cm)
  • Cabinet Backbox Dimensions: 14.5" W x 15" H x 3" D (36.83 W x 38.10 H x 7.62 D cm)
  • Cabinet Color: Red
  • Size: 7 AH max allowed in FACP
  • Charging Capacity: 18 AH
  • Charging Circuit: 27.6 VDC @ 0.8A max normal flat charge
  • Battery Type: Sealed lead acid only
  • Current: 500 mA max, power-limited; total current for nonresettable power, resettable power and two NACs must not exceed 6.0A (requires additional transformer)
  • Operating Voltage: 24 VDC nominal
  • Wiring: 14 AWG (2.0 mm2) with 600 V insulation min
  • Primary AC: 120 VAC @ 50/60 Hz, 2.3A


  • Silent or audible walk test operation mode
  • Optional module converts all IDCs and NACs to Class A (PN SK-CAC4)
  • Two Style Y (Class B) notification appliance circuit (NAC)
  • Four Style B (Class B) initiating device circuits (IDCs)
  • Alarm verification selectable per zone
  • Program each zone for supervisory or fire with separate red and yellow LEDs
  • Disable switches provided per zone
  • Form C alarm, trouble, and supervisory relays
  • 3A total usable current
  • 6A total usable current with optional second transformer (PN SK-TRM24 or SK-TRM24E)
  • Optional dress panel (PN SK-DP2/4)
  • Program for combination tamper supervisory monitor and waterflow alarm on one zone
  • Selective silence feature allows manual silence of horns while strobes continue to flash on the same NAC
  • Selectable for System Sensor, Wheelock, and Gentex protocols
  • Support for synchronization of standard ANSI audible signals and ADA compliant strobes per NFPA 72

Supplier product information

Technical Specifications

Battery TypeSealed lead acid only
BrandSilent Knight
Cabinet Backbox Dimensions14.5" W x 15" H x 3" D (36.83 W x 38.10 H x 7.62 D cm)
Cabinet ColorRed
Cabinet Door14.677" W x 15.342" H x 0.375" D (37.28 W x 38.97 H x 0.95 D cm)
Charging Capacity18 AH
Charging Circuit27.6 VDC @ 0.8A max normal flat charge
Current500 mA max, power-limited; total current for nonresettable power, resettable power and two NACs must not exceed 6.0A (requires additional transformer)
Manufacturer Part NumberSK-4
Operating Voltage24 VDC nominal
Primary AC120 VAC @ 50/60 Hz, 2.3A
Size7 AH max allowed in FACP
UPC783008107598
Wiring14 AWG (2.0 mm2) with 600 V insulation min

Documents & Technical Downloads

Simplex 4007-9202 (4007ES FACP, IDNAC)

Simplex 4007-9202 (4007ES FACP, IDNAC)

Indicative Price

from

Simplex 4004-9302 (Suppression Releasing Panel)

Simplex 4004-9302 (Suppression Releasing Panel)

Indicative Price

from

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Indicative Price

from

Simplex 4007-9102 (Fire Alarm Control Panel)

Simplex 4007-9102 (Fire Alarm Control Panel)

Indicative Price

from