Silent Knight 5128 4-Channel Fire Alarm Communicator
Communication Gateways

Silent Knight 5128 4-Channel Fire Alarm Communicator

Silent Knight·SKU: 5128

Indicative Price

Excluding local taxes and shipping.

The SILENT-KNIGHT-5128 is a fire communicator that provides four fully supervised channel inputs to monitor UL listed fire alarm systems. The 5128 comes in a vinyl and acrylic enclosure for mounting in the fire alarm control panel (FACP) cabinet and the unit can report AC power trouble using a dry c

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The SILENT-KNIGHT-5128 is a fire communicator that provides four fully supervised channel inputs to monitor UL listed fire alarm systems.

The 5128 comes in a vinyl and acrylic enclosure for mounting in the fire alarm control panel (FACP) cabinet and the unit can report AC power trouble using a dry contact active high voltage input.

UPC: 783196001142
Also known as: SK-5128

Technical Specifications:
  • Dimensions: 4" W x 8.75" H x 1.25" D ( 10.2 W x 22.2 H x 3.2 D cm)
  • Color: Black
  • Weight: 2 lbs (0.907 kg)
  • Watchdog Response: 50 sec. max
  • AC Monitor Input (5129 only): AC trouble output from FACP or 120 VAC
  • Dry Contact Current: 4.7 VDC, 6 mA max
  • Active High Current: 15 mA max
  • Channel Inputs: 18 – 30 VDC
  • Alarm Current without Annunciator: 154 mA @ 24 VDC max
  • Alarm Current with Annunciator: 227 mA@ 24 VDC max
  • Standby Current without Annunciator: 84 mA@ 24 VDC max
  • Standby Current with Annunciator: 143 mA@ 24 VDC max
  • Total DC Load: 84 mA @ 24 VDC max
  • Primary DC: 18 – 40 VDC
  • Primary AC: 120 VAC, 60 Hz, 45 mA


  • Easy to install and service
  • Reports in most major formats
  • Dual phone line interface and line fault monitors
  • Four fully supervised input channels programmable as voltage input active high or low or as a contact closure input
  • UL listed as a fire communicator for connection to UL listed 24 VDC local fire alarm control panels

Supplier product information

Technical Specifications

AC Monitor Input (5129 only)AC trouble output from FACP or 120 VAC
Active High Current15 mA max
Alarm Current with Annunciator227 mA@ 24 VDC max
Alarm Current without Annunciator154 mA @ 24 VDC max
BrandSilent Knight
Channel Inputs18 – 30 VDC
ColorBlack
Dimensions4" W x 8.75" H x 1.25" D ( 10.2 W x 22.2 H x 3.2 D cm)
Dry Contact Current4.7 VDC, 6 mA max
Manufacturer Part Number5128
Primary AC120 VAC, 60 Hz, 45 mA
Primary DC18 – 40 VDC
Standby Current with Annunciator143 mA@ 24 VDC max
Standby Current without Annunciator84 mA@ 24 VDC max
Total DC Load84 mA @ 24 VDC max
UPC783196001142
Watchdog Response50 sec. max
Weight2 lbs (0.907 kg)

Documents & Technical Downloads