Shield SHIELD1230
Clean Agent Fire Suppression Systems

Shield SHIELD1230

Shield·SKU: SHIELD1230

Our robust SHIELD1230 Engineered Fire Suppression systems are Underwriters Laboratories Inc. (UL) listed, and FM Approved. Designed for total flooding, our systems are built in full compliance with the NFPA 2001 “Standard on Clean Agent Fire Extinguishing Systems” and UL 2166 Standard for Halocarbon Clean Agent Extinguishing System Units. Overall, the application and installation of SHIELD1230 must meet the requirements or standards set by the Local Authority Having Jurisdiction.

Request a quote

Description

Our robust SHIELD1230 Engineered Fire Suppression systems are Underwriters Laboratories Inc. (UL) listed, and FM Approved. Designed for total flooding, our systems are built in full compliance with the NFPA 2001 “Standard on Clean Agent Fire Extinguishing Systems” and UL 2166 Standard for Halocarbon Clean Agent Extinguishing System Units. Overall, the application and installation of SHIELD1230 must meet the requirements or standards set by the Local Authority Having Jurisdiction.

Features

Features

    • Effective against Class A, B, and C fires
    • Colourless, odourless, and non-contaminating gaseous fire protection
    • Protect critical assets and processes without causing damage
    • Little to no post-discharge clean-up
    • Safe to use in occupied areas
    • Proven by thousands of successful installations worldwide

    Applications

    • Computer suites & data centers
    • Gas turbine enclosure
    • Offshore oil & gas exploration and production facilities
    • Telecommunication centres
    • Power generation
    • Marine
    • Museum, archives & data storage

Specifications

CYLINDERS DIMENSIONS & FILL RANGE

Size (L) Part Number Valve Size (in) Height (mm), A Height (mm), B Cylinder Diameter
(mm), C
Min Fill
(KG)
Max Fill
(KG)
Nominal Tare
Weight
(KG)
16.7 SD-17FK5-01 1 653 (25.7″) 564 (22.2″) 228.6(9″) 8.4 20 17.3
28.3 SD-28FK5-01 1 954 (37.6″) 865 (34″) 228.6(9″) 14.2 33.9 24.9
52 SD-52FK5-02 2 721 (28.4″ 597 (23.5″) 4 406 (16″) 26.1 62.4 52.4
106 SD-106FK5-02 2 1159 (45.6″) 1 1029 (40.5″) 406 (16″) 53.1 127.2 78.6
147 SD-147FK5-02 2 1494 (58.8″) 1 1364 (53.7″) 406 (16″) 73.6 176.4 100.1
180 SD-180FK5-02 2 1774 (69.8″) 1 1644 (64.7″) 406 (16″) 90.1 1 216 116.3
369 SD-369FK5-03 3 1734 (68.3″) 1 1569 (61.8″) 610 (24″) 184.6 3 442.8 241.3

Official manufacturer product information

Technical Specifications

106Part Number: SD-106FK5-02; Valve Size (in): 2; Height (mm), A: 1159 (45.6″) 1; Height (mm), B: 1029 (40.5″); Cylinder Diameter (mm), C: 406 (16″); Min Fill (KG): 53.1; Max Fill (KG): 127.2; Nominal Tare Weight (KG): 78.6
147Part Number: SD-147FK5-02; Valve Size (in): 2; Height (mm), A: 1494 (58.8″) 1; Height (mm), B: 1364 (53.7″); Cylinder Diameter (mm), C: 406 (16″); Min Fill (KG): 73.6; Max Fill (KG): 176.4; Nominal Tare Weight (KG): 100.1
16.7Part Number: SD-17FK5-01; Valve Size (in): 1; Height (mm), A: 653 (25.7″); Height (mm), B: 564 (22.2″); Cylinder Diameter (mm), C: 228.6(9″); Min Fill (KG): 8.4; Max Fill (KG): 20; Nominal Tare Weight (KG): 17.3
180Part Number: SD-180FK5-02; Valve Size (in): 2; Height (mm), A: 1774 (69.8″) 1; Height (mm), B: 1644 (64.7″); Cylinder Diameter (mm), C: 406 (16″); Min Fill (KG): 90.1 1; Max Fill (KG): 216; Nominal Tare Weight (KG): 116.3
28.3Part Number: SD-28FK5-01; Valve Size (in): 1; Height (mm), A: 954 (37.6″); Height (mm), B: 865 (34″); Cylinder Diameter (mm), C: 228.6(9″); Min Fill (KG): 14.2; Max Fill (KG): 33.9; Nominal Tare Weight (KG): 24.9
369Part Number: SD-369FK5-03; Valve Size (in): 3; Height (mm), A: 1734 (68.3″) 1; Height (mm), B: 1569 (61.8″); Cylinder Diameter (mm), C: 610 (24″); Min Fill (KG): 184.6 3; Max Fill (KG): 442.8; Nominal Tare Weight (KG): 241.3
52Part Number: SD-52FK5-02; Valve Size (in): 2; Height (mm), A: 721 (28.4″; Height (mm), B: 597 (23.5″) 4; Cylinder Diameter (mm), C: 406 (16″); Min Fill (KG): 26.1; Max Fill (KG): 62.4; Nominal Tare Weight (KG): 52.4
Manufacturer modelSHIELD1230
Published manufacturer stated standards statement 1Our robust SHIELD1230 Engineered Fire Suppression systems are Underwriters Laboratories Inc. (UL) listed, and FM Approved. Designed for total flooding, our systems are built in full compliance with the NFPA 2001 “Standard on Clean Agent Fire Extinguishing Systems” and UL 2166 Standard for Halocarbon Clean Agent Extinguishing System Units. Overall, the application and installation of SHIELD1230 must meet the requirements or standards set by the Local Authority Having Jurisdiction.