Shield POWER  SUPPLY UNIT
Power Supplies

Shield POWER SUPPLY UNIT

Shield·SKU: SHIELD-F-7160

The Shield AUL series of power supplies is designed to provide the power and flexibility needed for the most demanding fire system installations. The AUL-NX10AB/R is a 10 Amp unit, whereas the AUL-NX06AR is a 6 Amp, 24Vdc switch-mode power supply design. This design, which is up to 50% more efficient than linear mode supplies, makes the AUL series the best choice for powering fire system notification appliances and accessories. New and retrofit construction requirements for ADA compliance are ea

Request a quote

Description

The Shield AUL series of power supplies is designed to provide the power and flexibility needed for the most demanding fire system installations. The AUL-NX10AB/R is a 10 Amp unit, whereas the AUL-NX06AR is a 6 Amp, 24Vdc switch-mode power supply design. This design, which is up to 50% more efficient than linear mode supplies, makes the AUL series the best choice for powering fire system notification appliances and accessories.

New and retrofit construction requirements for ADA compliance are easily accomplished with ample power for additional notification appliances, along with the ability to synchronize the notification appliances using built-in sync generation for Shield, System Sensor®, Gentex®, and Wheelock® notification appliances. The AUL series goes even further to make retrofits easier with the advanced Quadra Sync feature, allowing notification appliances from different manufacturers to sync with each other.

You also have the option to monitor an existing circuit by placing a reference resistor of the same value on the power supply and continuing to monitor the circuit without changing the field EOL.

 

For Product manual please contact info@shieldglobal.com

Features

  • Input voltage: 120/240VAC 50/60Hz
  • Output voltage:
  • 24VDC @ 6A on the AUL-NX06AR,
  • 24VDC @ 10A on the AUL-NX10AB/R
  • Four class “B” notification circuits on the AUL-NX06AR
  • Rated at 3 amps max each
  • Can be configured as up to two class “A” Style “Z” notification circuits
  • Six class “B” Style “Y” notification circuits on the AUL-NX10AB/R
  • Rated at 3 amps max each
  • Can be configured as up to three class “A” Style “Z” notification circuits
  • Supervised Battery Charger: 27.3 @ 1A (supports 7-55 Ahr batteries)
  • Integrated battery cut-off circuitry to protect batteries from deep discharge
  • Two Trouble Relays (5A at 30VDC)
  • General System Trouble (programmable for AC delay via dip-switch)
  • Low AC Trouble
  • Diagnostic LED’s
  • Status LED’s for Active NAC and NAC trouble conditions
  • Status LED’s for Earth Fault (Amber), AC (Green), Battery Fault (Amber)
  • Trouble Memory feature captures troubles which have previously restored.
  • Synchronized notification appliance circuits
  • Shield
  • Wheelock®
  • Gentex®
  • System Sensor®
  • Configurable output circuits (D.I.P. switch sets options for each circuit)
  • ANSI temporal-coded
  • Constant Power
  • Door-Holder Power
  • Separate DC Power Output (3A)
  • Two Trigger Inputs (Class A, Style Z or Class B, Style Y)
  • Reference EOL terminals, allows 2K – 27K EOL value to be used
  • QuadraSync panel wide synchronization of same or multiple brands.
  • PassThru mode copies input signals to output (can be used in conjunction with QuadraSync)

Catalogue family reference SHIELD-F-7160 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.

Official manufacturer product information

Technical Specifications

Catalogue family referenceSHIELD-F-7160
Input voltage120/240VAC 50/60Hz
Published operating voltage statement 1The Shield AUL series of power supplies is designed to provide the power and flexibility needed for the most demanding fire system installations. The AUL-NX10AB/R is a 10 Amp unit, whereas the AUL-NX06AR is a 6 Amp, 24Vdc switch-mode power supply design. This design, which is up to 50% more efficient than linear mode supplies, makes the AUL series the best choice for powering fire system notification appliances and accessories.
Published operating voltage statement 2Input voltage: 120/240VAC 50/60Hz
Published operating voltage statement 324VDC @ 6A on the AUL-NX06AR,
Published operating voltage statement 424VDC @ 10A on the AUL-NX10AB/R
Published operating voltage statement 5Two Trouble Relays (5A at 30VDC)
Supervised Battery Charger27.3 @ 1A (supports 7-55 Ahr batteries)

Documents & Technical Downloads

Hochiki FN-PS776 Power Supply

Hochiki FN-PS776 Power Supply

Indicative Price

from

Hochiki PL-3 ESP Device Programming Lead 3WAY CONNECTOR

Hochiki PL-3 ESP Device Programming Lead 3WAY CONNECTOR

Indicative Price

from

Edwards 4-PPS/M (Primary Power Supply)

Edwards 4-PPS/M (Primary Power Supply)

Indicative Price

from