Shield DELUGE VALVES
Deluge valves

Shield DELUGE VALVES

Shield·SKU: SHIELD-F-23769

MODEL: SD-DVH3 / SD DVA / SD DVH5 / SD DVH52 / SD DVH300

Request a quote

Description

MODEL: SD-DVH3 / SD DVA / SD DVH5 / SD DVH52 / SD DVH300

Features

MODEL: SD-DVH3

Normal Size 200, 150, 100, 80, 50 NB
Material Ductile Iron ASTM A536-77 Grade 65-45-12
Sevice Pressure 1.4 to 17.5 Bar (20 to 250 PSI)
Threaded Opening BSPT
Mounting Vertical or Horizontal
Factory Hydrostatic Test Pressure 35 Kg/sq.cm. (500 PSI)
Flange Connection ANSI B 16.5 # 150 FF (RF-Optional)
Wet Pilot Sprinkler As per graph in the catalogue
FINISH RAL 3000
Ordering Information 1. Size of Valve
2. Flange specification
3. Valve trim vertical or horizontal
4. Trim type
End Connection Flange x Flange
Groove x Groove

 

MODEL: SD-DVA

Normal Size 200, 150, 100, 80 & 50 NB
MAXIMUM SERVICE 12 Bar (175 PSI) PRESSURE
THREADED OPENING BSPT/td>
MOUNTING 90° pattern inlet to outlet vertical mounting
Mounting Vertical or Horizontal
Factory Hydrostatic Test Pressure 25 Kg/sq.cm. (350 PSI)
Flange Connection ANSI B 16.1 FF # 125 FF (Flange drilling matching to ANSI B 16.5 # 150)
TRIM Galvanized Steel with Brass Valves
WET PILOT SPRINKLER HEIGHT LIMITATION As per graph in the catalogue
FINISH Red RAL 3000
APPROVAL UL Listed
ORDERING INFORMATION Specify
1) Size of valve
2) Trim type -Dry Pilot, Wet Pilot. Electric Release, Test & Alarm

 

MODEL: SD-DVH5

Normal Size 200, 150, 100, 80, 50 NB
Material Nickel Aluminium Bronze
Sevice Pressure 1.4 to 17.5 Bar (20 to 250 PSI)
Threaded Opening BSPT
Mounting Vertical or Horizontal
Factory Hydrostatic Test Pressure 35 Kg/sq.cm. (500 PSI)
Flange Connection ANSI B 16.5 # 150 FF (RF-Optional)
Wet Pilot Sprinkler As per graph in the catalogue
FINISH RAL 3000
Ordering Information 1. Size of Valve
2. Flange specification
3. Valve trim vertical or horizontal
4. Trim type

MODEL: SD-DVH2

Normal Size 200, 150, 100, 80, 50 NB
Material Cast Steel (20 to 250 PSI)
Sevice Pressure 1.4 to 17.5 Bar (20 to 250 PSI
Threaded Opening BSPT
Mounting Vertical or Horizontal
Factory Hydrostatic Test Pressure 35 Kg/sq.cm. (500 PSI)
Flange Connection ANSI B 16.5 # 150 RF (FF-Optional)
Wet Pilot Sprinkler As per graph in the catalogue
FINISH RAL 3000
Ordering Information 1. Size of Valve
2. Flange specification
3. Valve trim vertical or horizontal
4. Trim type

MODEL: SDDVH300

Normal Size 50, 65, 80, 100, 150, 200, 250, 300 NB
End connection: Flange x Flange, Flange x Groove, Groove x Groove
Working Pressure 300 Psi
Mode of actuation:- Wet Pilot actuation
Dry Pilot actuation
Electrical actuation
Flange Connection ANSI B 16.5 # 150 (Other flange types are available upon request).
Grooved connections are cut in accordance with
standard groove specification for steel pipe
High Pressure, High Flow Deluge System Superior
design featuring exceptionally low pressure losses at
high flow rates
Low to negligible lifelong maintenance costs to no
wetted metallic and mechanical moving parts design.
For use in dry pipe (automatic sprinkler) fire protection
system.
Automatic or local manual emergency actuation
Hazardous – flammable and explosion classified are fire
suppression
Use for electrical signal trigger system and pipeline
connection diagram system, manual-reset
Onshore & Oshore, naval, industrial, commercial &
residential fire suppression
Installed both vertical and horizontal orientation
Fusion Bonded epoxy coated interior and exterior to
AWWA C550 standard.

Catalogue family reference SHIELD-F-23769 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.

Official manufacturer product information

Technical Specifications

APPROVALUL Listed
Catalogue family referenceSHIELD-F-23769
End ConnectionFlange x Flange Groove x Groove
End connection:Flange x Flange, Flange x Groove, Groove x Groove
Factory Hydrostatic Test Pressure35 Kg/sq.cm. (500 PSI)
Factory Hydrostatic Test Pressure (2)25 Kg/sq.cm. (350 PSI)
FINISHRAL 3000
FINISH (2)Red RAL 3000
Flange ConnectionANSI B 16.5 # 150 FF (RF-Optional)
Flange Connection (2)ANSI B 16.1 FF # 125 FF (Flange drilling matching to ANSI B 16.5 # 150)
Flange Connection (3)ANSI B 16.5 # 150 RF (FF-Optional)
Flange Connection (4)ANSI B 16.5 # 150 (Other flange types are available upon request).
MaterialDuctile Iron ASTM A536-77 Grade 65-45-12
Material (2)Nickel Aluminium Bronze
Material (3)Cast Steel (20 to 250 PSI)
MAXIMUM SERVICE12 Bar (175 PSI) PRESSURE
Mode of actuation:-Wet Pilot actuation Dry Pilot actuation Electrical actuation
MountingVertical or Horizontal
MOUNTING (2)90° pattern inlet to outlet vertical mounting
Normal Size200, 150, 100, 80, 50 NB
Normal Size (2)200, 150, 100, 80 & 50 NB
Normal Size (3)50, 65, 80, 100, 150, 200, 250, 300 NB
Ordering Information1. Size of Valve 2. Flange specification 3. Valve trim vertical or horizontal 4. Trim type
ORDERING INFORMATION (2)Specify 1) Size of valve 2) Trim type -Dry Pilot, Wet Pilot. Electric Release, Test & Alarm
Sevice Pressure1.4 to 17.5 Bar (20 to 250 PSI)
Sevice Pressure (2)1.4 to 17.5 Bar (20 to 250 PSI
Threaded OpeningBSPT
THREADED OPENING (2)BSPT/td>
TRIMGalvanized Steel with Brass Valves
Wet Pilot SprinklerAs per graph in the catalogue
WET PILOT SPRINKLER HEIGHT LIMITATIONAs per graph in the catalogue
Working Pressure300 Psi

Documents & Technical Downloads