Deluge valves
Shield DELUGE VALVES
Shield·SKU: SHIELD-F-23769
MODEL: SD-DVH3 / SD DVA / SD DVH5 / SD DVH52 / SD DVH300
Request a quoteDescription
MODEL: SD-DVH3 / SD DVA / SD DVH5 / SD DVH52 / SD DVH300
Features
MODEL: SD-DVH3
| Normal Size | 200, 150, 100, 80, 50 NB |
| Material | Ductile Iron ASTM A536-77 Grade 65-45-12 |
| Sevice Pressure | 1.4 to 17.5 Bar (20 to 250 PSI) |
| Threaded Opening | BSPT |
| Mounting | Vertical or Horizontal |
| Factory Hydrostatic Test Pressure | 35 Kg/sq.cm. (500 PSI) |
| Flange Connection | ANSI B 16.5 # 150 FF (RF-Optional) |
| Wet Pilot Sprinkler | As per graph in the catalogue |
| FINISH | RAL 3000 |
| Ordering Information | 1. Size of Valve 2. Flange specification 3. Valve trim vertical or horizontal 4. Trim type |
| End Connection | Flange x Flange Groove x Groove |
MODEL: SD-DVA
| Normal Size | 200, 150, 100, 80 & 50 NB |
| MAXIMUM SERVICE | 12 Bar (175 PSI) PRESSURE |
| THREADED OPENING | BSPT/td> |
| MOUNTING | 90° pattern inlet to outlet vertical mounting |
| Mounting | Vertical or Horizontal |
| Factory Hydrostatic Test Pressure | 25 Kg/sq.cm. (350 PSI) |
| Flange Connection | ANSI B 16.1 FF # 125 FF (Flange drilling matching to ANSI B 16.5 # 150) |
| TRIM | Galvanized Steel with Brass Valves |
| WET PILOT SPRINKLER HEIGHT LIMITATION | As per graph in the catalogue |
| FINISH | Red RAL 3000 |
| APPROVAL | UL Listed |
| ORDERING INFORMATION | Specify 1) Size of valve 2) Trim type -Dry Pilot, Wet Pilot. Electric Release, Test & Alarm |
MODEL: SD-DVH5
| Normal Size | 200, 150, 100, 80, 50 NB |
| Material | Nickel Aluminium Bronze |
| Sevice Pressure | 1.4 to 17.5 Bar (20 to 250 PSI) |
| Threaded Opening | BSPT |
| Mounting | Vertical or Horizontal |
| Factory Hydrostatic Test Pressure | 35 Kg/sq.cm. (500 PSI) |
| Flange Connection | ANSI B 16.5 # 150 FF (RF-Optional) |
| Wet Pilot Sprinkler | As per graph in the catalogue |
| FINISH | RAL 3000 |
| Ordering Information | 1. Size of Valve 2. Flange specification 3. Valve trim vertical or horizontal 4. Trim type |
MODEL: SD-DVH2
| Normal Size | 200, 150, 100, 80, 50 NB |
| Material | Cast Steel (20 to 250 PSI) |
| Sevice Pressure | 1.4 to 17.5 Bar (20 to 250 PSI |
| Threaded Opening | BSPT |
| Mounting | Vertical or Horizontal |
| Factory Hydrostatic Test Pressure | 35 Kg/sq.cm. (500 PSI) |
| Flange Connection | ANSI B 16.5 # 150 RF (FF-Optional) |
| Wet Pilot Sprinkler | As per graph in the catalogue |
| FINISH | RAL 3000 |
| Ordering Information | 1. Size of Valve 2. Flange specification 3. Valve trim vertical or horizontal 4. Trim type |
MODEL: SDDVH300
| Normal Size | 50, 65, 80, 100, 150, 200, 250, 300 NB |
| End connection: | Flange x Flange, Flange x Groove, Groove x Groove |
| Working Pressure | 300 Psi |
| Mode of actuation:- | Wet Pilot actuation Dry Pilot actuation Electrical actuation |
| Flange Connection | ANSI B 16.5 # 150 (Other flange types are available upon request). |
| Grooved connections are cut in accordance with standard groove specification for steel pipe |
|
| High Pressure, High Flow Deluge System Superior design featuring exceptionally low pressure losses at high flow rates |
|
| Low to negligible lifelong maintenance costs to no wetted metallic and mechanical moving parts design. |
|
| For use in dry pipe (automatic sprinkler) fire protection system. |
|
| Automatic or local manual emergency actuation Hazardous – flammable and explosion classified are fire suppression |
|
| Use for electrical signal trigger system and pipeline connection diagram system, manual-reset |
|
| Onshore & Oshore, naval, industrial, commercial & residential fire suppression |
|
| Installed both vertical and horizontal orientation | |
| Fusion Bonded epoxy coated interior and exterior to AWWA C550 standard. |
Catalogue family reference SHIELD-F-23769 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.
Technical Specifications
| APPROVAL | UL Listed |
|---|---|
| Catalogue family reference | SHIELD-F-23769 |
| End Connection | Flange x Flange Groove x Groove |
| End connection: | Flange x Flange, Flange x Groove, Groove x Groove |
| Factory Hydrostatic Test Pressure | 35 Kg/sq.cm. (500 PSI) |
| Factory Hydrostatic Test Pressure (2) | 25 Kg/sq.cm. (350 PSI) |
| FINISH | RAL 3000 |
| FINISH (2) | Red RAL 3000 |
| Flange Connection | ANSI B 16.5 # 150 FF (RF-Optional) |
| Flange Connection (2) | ANSI B 16.1 FF # 125 FF (Flange drilling matching to ANSI B 16.5 # 150) |
| Flange Connection (3) | ANSI B 16.5 # 150 RF (FF-Optional) |
| Flange Connection (4) | ANSI B 16.5 # 150 (Other flange types are available upon request). |
| Material | Ductile Iron ASTM A536-77 Grade 65-45-12 |
| Material (2) | Nickel Aluminium Bronze |
| Material (3) | Cast Steel (20 to 250 PSI) |
| MAXIMUM SERVICE | 12 Bar (175 PSI) PRESSURE |
| Mode of actuation:- | Wet Pilot actuation Dry Pilot actuation Electrical actuation |
| Mounting | Vertical or Horizontal |
| MOUNTING (2) | 90° pattern inlet to outlet vertical mounting |
| Normal Size | 200, 150, 100, 80, 50 NB |
| Normal Size (2) | 200, 150, 100, 80 & 50 NB |
| Normal Size (3) | 50, 65, 80, 100, 150, 200, 250, 300 NB |
| Ordering Information | 1. Size of Valve 2. Flange specification 3. Valve trim vertical or horizontal 4. Trim type |
| ORDERING INFORMATION (2) | Specify 1) Size of valve 2) Trim type -Dry Pilot, Wet Pilot. Electric Release, Test & Alarm |
| Sevice Pressure | 1.4 to 17.5 Bar (20 to 250 PSI) |
| Sevice Pressure (2) | 1.4 to 17.5 Bar (20 to 250 PSI |
| Threaded Opening | BSPT |
| THREADED OPENING (2) | BSPT/td> |
| TRIM | Galvanized Steel with Brass Valves |
| Wet Pilot Sprinkler | As per graph in the catalogue |
| WET PILOT SPRINKLER HEIGHT LIMITATION | As per graph in the catalogue |
| Working Pressure | 300 Psi |