Shield Deluge & Single Double Supervised Pre Action System
MODEL: SD-DVH2S / SD-DVH2C / SD-DVH2S-SD / SD-DVH2C-SD/ SD-DVH2S-DEP / SD-DVH2C-DEP / SD-DVH2S-SE / SD-DVH2C-SE / SD-DVH2S-DEE / SD-DVH2C-DEE / SD-DVH3 / SD-DVH3S-SW / SD-DVH3C-SW / SD-DVH3S-SW / SD-DVH3C-SW / SD-DVH3S-SD / SD-DVH3C-SD / SD-DVH3S-DEP /SD-DVH3C-DEP / SD-DVH3S-SE /SD-DVH3C-SE / SD-DVH3S-DEE / SD-DVH3C-DEE SHIELD Supervised Deluge Pre-action System are used to protect areas where water damage from damaged sprinklers or piping must be avoided. A pre-alarm of a possible fire allows t
Request a quoteDescription
MODEL: SD-DVH2S / SD-DVH2C / SD-DVH2S-SD / SD-DVH2C-SD/ SD-DVH2S-DEP / SD-DVH2C-DEP / SD-DVH2S-SE / SD-DVH2C-SE / SD-DVH2S-DEE / SD-DVH2C-DEE / SD-DVH3 / SD-DVH3S-SW / SD-DVH3C-SW / SD-DVH3S-SW / SD-DVH3C-SW / SD-DVH3S-SD / SD-DVH3C-SD / SD-DVH3S-DEP /SD-DVH3C-DEP / SD-DVH3S-SE /SD-DVH3C-SE / SD-DVH3S-DEE / SD-DVH3C-DEE
SHIELD Supervised Deluge Pre-action System are used to protect areas where water damage from damaged sprinklers or piping must be avoided. A pre-alarm of a possible fire allows time for alternate fire extinguishment prior to a sprinkler discharge. They are designed for application such as refrigerated areas that require maximum protection against inadvertent operation of the sprinkler system.
Features
TYPES OF DELUGE PRE-ACTION SYSTEMS:
- Single Interlock Pre-Action System with Electric Release
- Single Interlock Pre-Action System with Dry Pilot Activation.
- Single Interlock Pre-Action System with Wet Pilot Activation.
- Double Interlock Pre-Action System with Electric/Electric Release
- Double Interlock Pre-Action System with Electric/Pneumatic Release
Specifications
SD-DVH2S SERIES
| SL.NO | Description | model |
|---|---|---|
| 1 | Size | 50, 80, 100, 150 & 200 NB (2”,3”,4”,6”,8”) |
| 2 | Deluge Valve | SD-DVH2, UL Listed |
| 3 | Riser Check Valve | SD-NRV250GG-D |
| 4 | Maximum Working Pressure | 250Psi |
| 5 | System End Connection | Flanged/Grooved (Optional) |
| 6 | Release Panel (SHIELD) | S230R-EXT (AX-T) Panel UL Listed |
| 7 | Water Flow Switch (SHIELD) | SD-PS 1001 UL Listed / SD-PS4001 (optional) |
| 8 | Low Pressure Alarm Switch (SHIELD) | SD-PS 1001 UL Listed / SD-PS4001 (optional) |
| 9 | Solenoid Valve | ASCO 8210G227, UL Listed |
| 10 | Automatic Air Supply | Oil Less Riser Mount Compressor (Optional) |
| 11 | Manual System Shut off Valve | Butterfly Valve or Gate Valve, UL Listed w/ UL Listed Tamper Switch (optional) |
| 12 | Cabinet, Red Finish | Red RAL 3000/3001/3020 (Epoxy Finish) Painting Suitable for Sea Water Application (Optional) |
| 13 | Trim Assembly | Galvanized Iron, SS, Monel (Optional For Sea Water Application) |
| 14 | Approval | UL Listed |
SD-DVH3 SERIES
| SL.NO | Description | model |
|---|---|---|
| 1 | Size | 50, 80, 100, 150 & 200 NB (2”,3”,4”,6”,8” |
| 2 | Deluge Valve | SD-DVH3, UL Listed |
| 3 | Riser Check Valve | SD-NRV250GG-D |
| 4 | Maximum Working Pressure | 250Psi |
| 5 | System End Connection | Flanged/Grooved (Optional) |
| 6 | Release Panel (SHIELD) | S230R-EXT (AX-T) Panel UL Listed |
| 7 | Water Flow Switch (SHIELD) | SD-PS 1001 UL Listed / SD-PS4001 (optional) |
| 8 | Low Pressure Alarm Switch (SHIELD) | SD-PS 1001 UL Listed / SD-PS4001 (optional) |
| 9 | Solenoid Valve | ASCO 8210G227, UL Listed |
| 10 | Automatic Air Supply | Oil Less Riser Mount Compressor (Optional) |
| 11 | Manual System Shut off Valve | Butterfly Valve or Gate Valve, UL Listed w/ UL Listed Tamper Switch (optional) |
| 12 | Cabinet, Red Finish | Red RAL 3000/3001/3020 (Epoxy Finish) Painting Suitable for Sea Water Application (Optional) |
| 13 | Trim Assembly | Galvanized Iron, SS, Monel (Optional For Sea Water Application) |
| 14 | Approval | UL Listed |
Catalogue family reference SHIELD-F-23947 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.
Technical Specifications
| 1 | Description: Size; model: 50, 80, 100, 150 & 200 NB (2”,3”,4”,6”,8”) |
|---|---|
| 1 (2) | Description: Size; model: 50, 80, 100, 150 & 200 NB (2”,3”,4”,6”,8” |
| 10 | Description: Automatic Air Supply; model: Oil Less Riser Mount Compressor (Optional) |
| 11 | Description: Manual System Shut off Valve; model: Butterfly Valve or Gate Valve, UL Listed w/ UL Listed Tamper Switch (optional) |
| 12 | Description: Cabinet, Red Finish; model: Red RAL 3000/3001/3020 (Epoxy Finish) Painting Suitable for Sea Water Application (Optional) |
| 13 | Description: Trim Assembly; model: Galvanized Iron, SS, Monel (Optional For Sea Water Application) |
| 14 | Description: Approval; model: UL Listed |
| 2 | Description: Deluge Valve; model: SD-DVH2, UL Listed |
| 2 (2) | Description: Deluge Valve; model: SD-DVH3, UL Listed |
| 3 | Description: Riser Check Valve; model: SD-NRV250GG-D |
| 4 | Description: Maximum Working Pressure; model: 250Psi |
| 5 | Description: System End Connection; model: Flanged/Grooved (Optional) |
| 6 | Description: Release Panel (SHIELD); model: S230R-EXT (AX-T) Panel UL Listed |
| 7 | Description: Water Flow Switch (SHIELD); model: SD-PS 1001 UL Listed / SD-PS4001 (optional) |
| 8 | Description: Low Pressure Alarm Switch (SHIELD); model: SD-PS 1001 UL Listed / SD-PS4001 (optional) |
| 9 | Description: Solenoid Valve; model: ASCO 8210G227, UL Listed |
| Catalogue family reference | SHIELD-F-23947 |