Shield Deluge & Single Double Supervised Pre Action System
Water Based Fire Suppression

Shield Deluge & Single Double Supervised Pre Action System

Shield·SKU: SHIELD-F-23947

MODEL: SD-DVH2S / SD-DVH2C / SD-DVH2S-SD / SD-DVH2C-SD/ SD-DVH2S-DEP / SD-DVH2C-DEP / SD-DVH2S-SE / SD-DVH2C-SE / SD-DVH2S-DEE / SD-DVH2C-DEE / SD-DVH3 / SD-DVH3S-SW / SD-DVH3C-SW / SD-DVH3S-SW / SD-DVH3C-SW / SD-DVH3S-SD / SD-DVH3C-SD / SD-DVH3S-DEP /SD-DVH3C-DEP / SD-DVH3S-SE /SD-DVH3C-SE / SD-DVH3S-DEE / SD-DVH3C-DEE SHIELD Supervised Deluge Pre-action System are used to protect areas where water damage from damaged sprinklers or piping must be avoided. A pre-alarm of a possible fire allows t

Request a quote

Description

MODEL: SD-DVH2S / SD-DVH2C / SD-DVH2S-SD / SD-DVH2C-SD/ SD-DVH2S-DEP / SD-DVH2C-DEP / SD-DVH2S-SE / SD-DVH2C-SE / SD-DVH2S-DEE / SD-DVH2C-DEE / SD-DVH3 / SD-DVH3S-SW / SD-DVH3C-SW / SD-DVH3S-SW / SD-DVH3C-SW / SD-DVH3S-SD / SD-DVH3C-SD / SD-DVH3S-DEP /SD-DVH3C-DEP / SD-DVH3S-SE /SD-DVH3C-SE / SD-DVH3S-DEE / SD-DVH3C-DEE

SHIELD Supervised Deluge Pre-action System are used to protect areas where water damage from damaged sprinklers or piping must be avoided. A pre-alarm of a possible fire allows time for alternate fire extinguishment prior to a sprinkler discharge. They are designed for application such as refrigerated areas that require maximum protection against inadvertent operation of the sprinkler system.

Features

TYPES OF DELUGE PRE-ACTION SYSTEMS:

  • Single Interlock Pre-Action System with Electric Release
  • Single Interlock Pre-Action System with Dry Pilot Activation.
  • Single Interlock Pre-Action System with Wet Pilot Activation.
  • Double Interlock Pre-Action System with Electric/Electric Release
  • Double Interlock Pre-Action System with Electric/Pneumatic Release

Specifications

SD-DVH2S SERIES

SL.NO Description model
1 Size 50, 80, 100, 150 & 200 NB (2”,3”,4”,6”,8”)
2 Deluge Valve SD-DVH2, UL Listed
3 Riser Check Valve SD-NRV250GG-D
4 Maximum Working Pressure 250Psi
5 System End Connection Flanged/Grooved (Optional)
6 Release Panel (SHIELD) S230R-EXT (AX-T) Panel UL Listed
7 Water Flow Switch (SHIELD) SD-PS 1001 UL Listed / SD-PS4001 (optional)
8 Low Pressure Alarm Switch (SHIELD) SD-PS 1001 UL Listed / SD-PS4001 (optional)
9 Solenoid Valve ASCO 8210G227, UL Listed
10 Automatic Air Supply Oil Less Riser Mount Compressor (Optional)
11 Manual System Shut off Valve Butterfly Valve or Gate Valve, UL Listed w/ UL Listed Tamper Switch (optional)
12 Cabinet, Red Finish Red RAL 3000/3001/3020 (Epoxy Finish)
Painting Suitable for Sea Water Application (Optional)
13 Trim Assembly Galvanized Iron, SS, Monel (Optional For Sea Water Application)
14 Approval UL Listed

 

SD-DVH3 SERIES

SL.NO Description model
1 Size 50, 80, 100, 150 & 200 NB (2”,3”,4”,6”,8”
2 Deluge Valve SD-DVH3, UL Listed
3 Riser Check Valve SD-NRV250GG-D
4 Maximum Working Pressure 250Psi
5 System End Connection Flanged/Grooved (Optional)
6 Release Panel (SHIELD) S230R-EXT (AX-T) Panel UL Listed
7 Water Flow Switch (SHIELD) SD-PS 1001 UL Listed / SD-PS4001 (optional)
8 Low Pressure Alarm Switch (SHIELD) SD-PS 1001 UL Listed / SD-PS4001 (optional)
9 Solenoid Valve ASCO 8210G227, UL Listed
10 Automatic Air Supply Oil Less Riser Mount Compressor (Optional)
11 Manual System Shut off Valve Butterfly Valve or Gate Valve, UL Listed w/ UL Listed Tamper Switch (optional)
12 Cabinet, Red Finish Red RAL 3000/3001/3020 (Epoxy Finish) Painting Suitable for Sea Water Application (Optional)
13 Trim Assembly Galvanized Iron, SS, Monel (Optional For Sea Water Application)
14 Approval UL Listed

Catalogue family reference SHIELD-F-23947 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.

Official manufacturer product information

Technical Specifications

1Description: Size; model: 50, 80, 100, 150 & 200 NB (2”,3”,4”,6”,8”)
1 (2)Description: Size; model: 50, 80, 100, 150 & 200 NB (2”,3”,4”,6”,8”
10Description: Automatic Air Supply; model: Oil Less Riser Mount Compressor (Optional)
11Description: Manual System Shut off Valve; model: Butterfly Valve or Gate Valve, UL Listed w/ UL Listed Tamper Switch (optional)
12Description: Cabinet, Red Finish; model: Red RAL 3000/3001/3020 (Epoxy Finish) Painting Suitable for Sea Water Application (Optional)
13Description: Trim Assembly; model: Galvanized Iron, SS, Monel (Optional For Sea Water Application)
14Description: Approval; model: UL Listed
2Description: Deluge Valve; model: SD-DVH2, UL Listed
2 (2)Description: Deluge Valve; model: SD-DVH3, UL Listed
3Description: Riser Check Valve; model: SD-NRV250GG-D
4Description: Maximum Working Pressure; model: 250Psi
5Description: System End Connection; model: Flanged/Grooved (Optional)
6Description: Release Panel (SHIELD); model: S230R-EXT (AX-T) Panel UL Listed
7Description: Water Flow Switch (SHIELD); model: SD-PS 1001 UL Listed / SD-PS4001 (optional)
8Description: Low Pressure Alarm Switch (SHIELD); model: SD-PS 1001 UL Listed / SD-PS4001 (optional)
9Description: Solenoid Valve; model: ASCO 8210G227, UL Listed
Catalogue family referenceSHIELD-F-23947