Shield Conventional Control Panel (8/16 Zones)
The P-C208A/216A conventional fire control panels provide eight/sixteen zones of fire detection. Panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL). Microprocessor controlled SMT Electronics Compliant with EN54 part 2&4, & BS5839, Part 4, 1988 Repeater Panel Interface Both end of l
Request a quoteDescription
The P-C208A/216A conventional fire control panels provide eight/sixteen zones of fire detection. Panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL).
- Microprocessor controlled SMT Electronics
- Compliant with EN54 part 2&4, & BS5839, Part 4, 1988
- Repeater Panel Interface
- Both end of line resistors and active end of line can be used.
- Programmable sounder circuits outputs
- Zone Isolate / Test control
- Fully monitored sounder circuits
- Key control evacuate over-ride
- Fire alarm output for remote control
- Class change terminals for remote control
- Up to 15 fire detectors and infinite manuals call points each zone.
Catalogue family reference SHIELD-F-6517 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.
Technical Specifications
| Catalogue family reference | SHIELD-F-6517 |
|---|---|
| Published manufacturer stated standards statement 1 | The P-C208A/216A conventional fire control panels provide eight/sixteen zones of fire detection. Panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL). |
| Published manufacturer stated standards statement 2 | Compliant with EN54 part 2&4, & BS5839, Part 4, 1988 |
Related Products
View Cataloguearrow_forward
Simplex 4007-9202 (4007ES FACP, IDNAC)
Indicative Price
from

Simplex 4004-9302 (Suppression Releasing Panel)
Indicative Price
from

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)
Indicative Price
from

Simplex 4007-9102 (Fire Alarm Control Panel)
Indicative Price
from