Shield Conventional Control Panel (8/16 Zones)
Conventional Fire Alarm Panels

Shield Conventional Control Panel (8/16 Zones)

Shield·SKU: SHIELD-F-6517

The P-C208A/216A conventional fire control panels provide eight/sixteen zones of fire detection. Panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL). Microprocessor controlled SMT Electronics Compliant with EN54 part 2&4, & BS5839, Part 4, 1988 Repeater Panel Interface Both end of l

Request a quote

Description

The P-C208A/216A conventional fire control panels provide eight/sixteen zones of fire detection. Panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL).

  • Microprocessor controlled SMT Electronics
  • Compliant with EN54 part 2&4, & BS5839, Part 4, 1988
  • Repeater Panel Interface
  • Both end of line resistors and active end of line can be used.
  • Programmable sounder circuits outputs
  • Zone Isolate / Test control
  • Fully monitored sounder circuits
  • Key control evacuate over-ride
  • Fire alarm output for remote control
  • Class change terminals for remote control
  • Up to 15 fire detectors and infinite manuals call points each zone.

Catalogue family reference SHIELD-F-6517 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.

Official manufacturer product information

Technical Specifications

Catalogue family referenceSHIELD-F-6517
Published manufacturer stated standards statement 1The P-C208A/216A conventional fire control panels provide eight/sixteen zones of fire detection. Panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL).
Published manufacturer stated standards statement 2Compliant with EN54 part 2&4, & BS5839, Part 4, 1988
Simplex 4007-9202 (4007ES FACP, IDNAC)

Simplex 4007-9202 (4007ES FACP, IDNAC)

Indicative Price

from

Simplex 4004-9302 (Suppression Releasing Panel)

Simplex 4004-9302 (Suppression Releasing Panel)

Indicative Price

from

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Indicative Price

from

Simplex 4007-9102 (Fire Alarm Control Panel)

Simplex 4007-9102 (Fire Alarm Control Panel)

Indicative Price

from