Shield Conventional Control Panel (2/4 Zones)
Conventional Fire Alarm Panels

Shield Conventional Control Panel (2/4 Zones)

Shield·SKU: SHIELD-F-6518

The P-C202A/204A conventional fire control panels provide two/four zones of fire detection. All panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL). Microprocessor controlled SMT Electronics Compliant with EN54 part 2&4, & BS5839, Part 4, 1988 Both end of line resistors and active e

Request a quote

Description

The P-C202A/204A conventional fire control panels provide two/four zones of fire detection. All panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL).

  • Microprocessor controlled SMT Electronics
  • Compliant with EN54 part 2&4, & BS5839, Part 4, 1988
  • Both end of line resistors and active end of line can be used.
  • Programmable sounder circuits outputs
  • Zone Isolate control
  • Fully monitored sounder circuits
  • Key control evacuate over-ride
  • Class change terminals for remote control
  • Up to 15 fire detectors and infinite manuals call points each zone.

Catalogue family reference SHIELD-F-6518 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.

Official manufacturer product information

Technical Specifications

Catalogue family referenceSHIELD-F-6518
Published manufacturer stated standards statement 1The P-C202A/204A conventional fire control panels provide two/four zones of fire detection. All panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. (Each zone can be connected with 15 conventional fire detectors and infinite no of MCB when using Active EOL).
Published manufacturer stated standards statement 2Compliant with EN54 part 2&4, & BS5839, Part 4, 1988
Simplex 4007-9202 (4007ES FACP, IDNAC)

Simplex 4007-9202 (4007ES FACP, IDNAC)

Indicative Price

from

Simplex 4004-9302 (Suppression Releasing Panel)

Simplex 4004-9302 (Suppression Releasing Panel)

Indicative Price

from

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Indicative Price

from

Simplex 4007-9102 (Fire Alarm Control Panel)

Simplex 4007-9102 (Fire Alarm Control Panel)

Indicative Price

from