Shield ADDRESSABLE MIKRO CONTROL PANELS
Addressable Fire Alarm Panels

Shield ADDRESSABLE MIKRO CONTROL PANELS

Shield·SKU: SHIELD-F-7125

Mikro is a single loop, analogue addressable control panel, based on the Shield protocols. It targets small to medium installations. The key points of this panel are low cost, ease of use through an intuitive user interface, expandability through networking and programming flexibility all in a robust, high quality construction. Easy for both installers and users provides an ideal solution for a certified entry level panel easily integrated in future installation expansions.

Request a quote

Description

Mikro is a single loop, analogue addressable control panel, based on the Shield protocols. It targets small to medium installations. The key points of this panel are low cost, ease of use through an intuitive user interface, expandability through networking and programming flexibility all in a robust, high quality construction. Easy for both installers and users provides an ideal solution for a certified entry level panel easily integrated in future installation expansions.

Features

  • One Loop Analogue Addressable control panels.
  • 2 Conventional Zones (Maximum 20 detectors per zone).
  • Manual add/remove of loop devices.
  • Up to 15 groups of outputs for simultaneous activation.
  • 2 Supervised Siren Outputs.
  • Siren pattern selection for on board (switched) and loop devices.
  • Storage of up to 2000 log events
  • System LED indications: Power, Fault, Alarm, Pre-Alarm, Delay Active, Sirens Silenced, On Test.
  • Walk Test installation testing feature.
  • Weekly reminder for system test.
  • Remote software monitoring and programming.

Specifications

TECHNICAL DATA
Number of loops 1
Loop current 400mA
Fire zones / Zonal indicators 16 (Mikro 16)
Conventional zones 2 (Maximum 20 detectors per zone)
Conventional zones termination resistors 4,7Κ Ohms / 1W
Supervised siren outputs 2 outputs, 24VDC ±10%, 1A max, fused and monitored
Generic trouble output (on main unit) non-monitored Dry relay contacts NO – C – NC
Generic Inputs 2 auxiliary, internally pulled up inputs.1.5mA sink activation current
Relay Outputs 2 general relay outputsN/O or N/C (jumper selectable) dry contacts 28V/3A max
PGM Outputs PGM outputsOpen collector, 200mA sink max current, 30V max handling
Earth faults detection and indication Front panel LCD indication & buzzer
Display 4 lines of 20 characters LCD
Mains Power 220 VAC 50Hz
Mains supply fuse 1.6A 250V
Power Supply 24 VDC / 2.50A
AUX output 24VDC +/- 700, %10mA max, current limited, monitored
Battery Backup power 2x 12V / 7Ah sealed lead acid gel batteries
Battery health monitoring (periodic load test) Every 90 seconds
Enclosure Epoxy powder coated metal box
Dimensions (H x W x D) [mm] 315 x 425 x 100
IP rating IP30

Catalogue family reference SHIELD-F-7125 identifies this manufacturer product page; it is not an orderable manufacturer SKU. Confirm the required model and configuration when requesting information.

Official manufacturer product information

Technical Specifications

AUX output24VDC +/- 700, %10mA max, current limited, monitored
Battery Backup power2x 12V / 7Ah sealed lead acid gel batteries
Battery health monitoring (periodic load test)Every 90 seconds
Catalogue family referenceSHIELD-F-7125
Conventional zones2 (Maximum 20 detectors per zone)
Conventional zones termination resistors4,7Κ Ohms / 1W
Dimensions (H x W x D) [mm]315 x 425 x 100
Display4 lines of 20 characters LCD
Earth faults detection and indicationFront panel LCD indication & buzzer
EnclosureEpoxy powder coated metal box
Fire zones / Zonal indicators16 (Mikro 16)
Generic Inputs2 auxiliary, internally pulled up inputs.1.5mA sink activation current
Generic trouble output (on main unit) non-monitoredDry relay contacts NO – C – NC
IP ratingIP30
Loop current400mA
Mains Power220 VAC 50Hz
Mains supply fuse1.6A 250V
Number of loops1
PGM OutputsPGM outputsOpen collector, 200mA sink max current, 30V max handling
Power Supply24 VDC / 2.50A
Relay Outputs2 general relay outputsN/O or N/C (jumper selectable) dry contacts 28V/3A max
Supervised siren outputs2 outputs, 24VDC ±10%, 1A max, fused and monitored
System LED indicationsPower, Fault, Alarm, Pre-Alarm, Delay Active, Sirens Silenced, On Test.

Documents & Technical Downloads

Simplex 4007-9201 (Fire Alarm Control Panel)

Simplex 4007-9201 (Fire Alarm Control Panel)

Indicative Price

from

Simplex 4010-9501 (4010Es Facp 240V)

Simplex 4010-9501 (4010Es Facp 240V)

Indicative Price

from

Simplex 4010-9502 (4010Es Facp 240V Red)

Simplex 4010-9502 (4010Es Facp 240V Red)

Indicative Price

from