MR-401RP
The MR-401RP Addressable Fire Alarm Control Panel is a 3 (SLC) loops addressable multi-zoned panel compatible with the new MRI-4000 Series .
Request a quoteDescription
The MR-401 Addressable Fire Alarm Control Panel is a 3 (SLC) loops addressable multi-zoned panel compatible with the new MRI-4000 Series.
4 Reasons to choose the MR-401RP Addressable Fire Alarm Control Panel:
- The panel is ideal for small to medium jobs. It is easy to install and configure.
- The MR-401RP is shipped pre-assembled. It comes with the mainboard, power supply, transformer, main display, black backbox, and a red door enclosure.
- The panel is compatible with the new MRI-4000 Series. It comes with one addressable (SLC) loop and it can have up to 3 loops, with a maximum of 240 MRI-4000 devices per loop. Connect the ALC-480 Dual Loop Adder to the panel to have the extra 2 (SLC) MRI-4000 devices compatible loops. The ALC-480 is sold separately.
- The MR-401RP is equipped with a built-in dialer. The dialer provides a means to communicate panel status to the remote central monitoring station using two dedicated phone lines.
Secutron’s MR-401RP Addressable Fire Alarm Control Panel provides the following:
- Main Board, Power Supply and Backbox.
- Flexible zone and group configuration options.
- 3500 Main Display with 4 x 20 LCD display.
- Class A (DCLA), Class X (DCLC), or Class B (DCLB) analog loop(s).
- Four Power Limited Class B, Class A NAC circuits (max 1.5 Amps each – 6.0 Amps total).
- Up to 3 MRI-4000 Compatible (SLC) loops with a maximum of 720 devices, 240 per loop.
- Dedicated common alarm, supervisory, trouble, and auxiliary alarm relays.
- Additional RAX-1048TZDS Display Adder Module can be added to provide 96 annunciation points per Adder.
- Additional outputs include connections for a remote trouble indicator MR-2300T, Reverse Polarity Module MR-2300-PR, an RS-485 bus for connection of up to seven RAX-LCD-LITE, RAM-3500-LCDs, SRM-312s and RA-1000 Series annunciators.
- Auxiliary power is available in the form of 24V FWR unfiltered and unsupervised, 24VDC filtered and regulated, and resettable auxiliary power supply.
- Built-in POTs dialer which allows for the reporting of events to a monitoring facility.
Technical Specifications
| Brand | Secutron |
|---|---|
| Feature 01 | The panel is ideal for small to medium jobs. It is easy to install and configure . |
| Feature 02 | The MR-401RP is shipped pre-assembled. It comes with the mainboard, power supply, transformer, main display, black backbox, and a red door enclosure. |
| Feature 03 | The panel is compatible with the new MRI-4000 Series. It comes with one addressable (SLC) loop and it can have up to 3 loops, with a maximum of 240 MRI-4000 devices per loop. Connect the ALC-480 Dual Loop Adder to the panel to have the extra 2 (SLC) MRI-4000 devices compatible loops. The ALC-480 is sold separately. |
| Feature 04 | The MR-401RP is equipped with a built-in dialer. The dialer provides a means to communicate panel status to the remote central monitoring station using two dedicated phone lines. |
| Feature 05 | Main Board, Power Supply and Backbox. |
| Feature 06 | Flexible zone and group configuration options. |
| Feature 07 | 3500 Main Display with 4 x 20 LCD display. |
| Feature 08 | Class A (DCLA), Class X (DCLC), or Class B (DCLB) analog loop(s). |
| Feature 09 | Four Power Limited Class B, Class A NAC circuits (max 1.5 Amps each – 6.0 Amps total). |
| Feature 10 | Up to 3 MRI-4000 Compatible (SLC) loops with a maximum of 720 devices, 240 per loop. |
| Feature 11 | Dedicated common alarm, supervisory, trouble, and auxiliary alarm relays. |
| Feature 12 | Additional RAX-1048TZDS Display Adder Module can be added to provide 96 annunciation points per Adder. |
| Feature 13 | Additional outputs include connections for a remote trouble indicator MR-2300T, Reverse Polarity Module MR-2300-PR, an RS-485 bus for connection of up to seven RAX-LCD-LITE, RAM-3500-LCDs, SRM-312s and RA-1000 Series annunciators. |
| Feature 14 | Auxiliary power is available in the form of 24V FWR unfiltered and unsupervised, 24VDC filtered and regulated, and resettable auxiliary power supply. |
| Feature 15 | Built-in POTs dialer which allows for the reporting of events to a monitoring facility. |
| Manufacturer part number / series | MR-401RP |
Documents & Technical Downloads
CAT-1042 MR-401 Addressable Fire Alarm Control Panel (English)
Datasheet
CAT-1042F Addressable Fire Alarm Control Panel (French Version)
Datasheet
CAT-1042S MR-401 Addressable Fire Alarm Control Panel (Spanish)
Datasheet
CAT-5371 RAM-3500-LCD Remote LCD Annuciator
Datasheet
CAT-5371F RAM-3500-LCD Remote LCD Annunciator
Datasheet
LT-6670SEC MR-401 Installation Manual
Manual
LT-1023SEC Device Compatibility Guide
Manual
LT-6772 Password Setup Instructions for MR-400 Series Password Configurator
Manual
SS-230037 MR-401 Series Sell Sheet (English)
Brochure
SS-230037 MR-401 Series Sell Sheet (French)
Brochure
BR-250015CDN EN Secutron FAS
Brochure
BR-250015CDN FR Secutron FAS
Brochure
MR-401 Engineering Specification
Document
MR-401 Series Frame and Post
Document
Related Products
View Cataloguearrow_forward
Simplex 4007-9201 (Fire Alarm Control Panel)
Indicative Price
from

Simplex 4010-9501 (4010Es Facp 240V)
Indicative Price
from

Simplex 4010-9502 (4010Es Facp 240V Red)
Indicative Price
from