Secutron’s MMX-4000 Series is designed to meet virtually any application of detection, control, notification, and emergency communications. Features such as fire detection & alarm, audio/voice evacuation, BACnet, Boolean logic, networking and graphical workstation support allow this modular solution to accommodate projects from the simplest systems up to the most complex solutions.

• MMX-4000 Series supports multiple intelligent protocols:

– MIX-4000 Devices
– Advanced Protocol (AP)
–  Classic Loop Interface Protocol (CLIP)

• Multiple User Interface Options including:
– 80 characters or 960 characters backlit LCD with the user-friendly menu;
– LED displays adders
– Up to 7 remote annunciators per node.

• Multiple languages are supported including English, French, Italian, Spanish, Portuguese, Arabic, Hebrew, Chinese, Japanese, Korean and Russian.

Fire Alarm Control Features

  • Expandable up to 28 SLC
  • Four Style Z/Y (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each with built-in sync protocol
  • Supports both 80 characters and 960 characters backlit LCD displays with a user-friendly menu
  • User Interface Tags and Labels in English, French, Italian, Spanish, Portuguese, Arabic*, Hebrew*, Chinese*, Japanese*, Korean* and Russian* (*needs DSPL-2440DS or RAXN-4000LCDG)
  • Tags only: it accepts all languages supported by Windows 10 (requires graphic annunciator)
  • Correlatable Switch Inputs which allows for multifunctional outputs
  • Sub-addressing to optimize the number of devices in each loop
  • Four Alarm Queues with selector switches and LEDs for Alarm, Supervisory, Monitor and Trouble
  • RS-232 output for remote system printer or terminal
  • RS-485 port for system expansion
  • Ethernet port for OpenGN workstation or BACNet interface
  • Two Event History Logs with capacity for 5000 Alarm Events and 5000 General Events
  • The system can be configured without taking the panel off-line
  • Supports three configuration files (current, previous, and next configuration) with “hot swap” support
  • Supports Boolean logic functions
  • Remote diagnostics via a built-in web server
  • UL listed for Smoke Control (UUKL).


Networking Features

The network configuration allows multiple MMX-4000 Series control panels to be connected using supervised Class A/B circuits to expand the available SLCs, input circuits, visual indication zones, programmable notification appliance circuits, relay outputs and monitor points in the application. The network interface module creates a robust peer-to-peer network via a proprietary protocol that ensures network segments operate independently in case of network impairment. The high baud rate of the network allows for multiplexing of control, audio, and telephony communications over a single copper or fiber interface using advanced compression algorithms. Twisted-Pair Copper, Single-Mode Fiber & Multi-Mode Fiber networking is supported.

  • Up to 63 nodes
  • Peer-to-peer network communications
  • Fully integrated digital network audio and control over a single pair of copper wire or fiber optic cable (single or multi-mode)
  • Remote diagnostics via a built-in web server and standard Ethernet port in every node
  • Style 4 (Class B) or Style 6 or 7 (Class A) wiring configuration
  • Proprietary ARCnet Network Communications protocol


MGC Protocol Features

For the new or retrofit expansion of existing applications, MGC Protocol, supports up to 240 devices per SLC Supports:

  • Photo, Heat, and Multi-criteria Sensors
  • Optional Built-In Isolation on Sensors
  • Multiple Input and Multiple Output modules


AP Protocol Features

Advanced Protocol (AP) supports up to 318 devices per SLC (159 sensors & 159 modules). Supports:

  • Smoke, Heat and Fire/CO detection
  •  Low Frequency 520 Hz sounder base support on both the addressable loop and through the audio/voice evacuation system.
  • Interrupt operation on the input side to speed detection of an event communication back to the panel
  • Group activation on the output to speed up actions on the outputs


CLIP Protocol Features

  • Address range for sensors S1-S99 – address range for modules M1-M99.
  • Wide range of addressable devices available.


Agency Listings

Official manufacturer product information

Technical Specifications

BrandSecutron
Feature 01Expandable up to 28 SLC
Feature 02Four Style Z/Y (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each with built-in sync protocol
Feature 03Supports both 80 characters and 960 characters backlit LCD displays with a user-friendly menu
Feature 04User Interface Tags and Labels in English, French, Italian, Spanish, Portuguese, Arabic*, Hebrew*, Chinese*, Japanese*, Korean* and Russian* (*needs DSPL-2440DS or RAXN-4000LCDG)
Feature 06Correlatable Switch Inputs which allows for multifunctional outputs
Feature 07Sub-addressing to optimize the number of devices in each loop
Feature 08Four Alarm Queues with selector switches and LEDs for Alarm, Supervisory, Monitor and Trouble
Feature 09RS-232 output for remote system printer or terminal
Feature 10RS-485 port for system expansion
Feature 11Ethernet port for OpenGN workstation or BACNet interface
Feature 12Two Event History Logs with capacity for 5000 Alarm Events and 5000 General Events
Feature 13The system can be configured without taking the panel off-line
Feature 14Supports three configuration files (current, previous, and next configuration) with “hot swap” support
Feature 15Supports Boolean logic functions
Feature 16Remote diagnostics via a built-in web server
Feature 17UL listed for Smoke Control (UUKL).
Feature 18Up to 63 nodes
Feature 19Peer-to-peer network communications
Feature 20Fully integrated digital network audio and control over a single pair of copper wire or fiber optic cable (single or multi-mode)
Feature 21Remote diagnostics via a built-in web server and standard Ethernet port in every node
Feature 22Style 4 (Class B) or Style 6 or 7 (Class A) wiring configuration
Feature 23Proprietary ARCnet Network Communications protocol
Feature 24Photo, Heat, and Multi-criteria Sensors
Feature 25Optional Built-In Isolation on Sensors
Feature 26Multiple Input and Multiple Output modules
Feature 27Smoke, Heat and Fire/CO detection
Feature 28Low Frequency 520 Hz sounder base support on both the addressable loop and through the audio/voice evacuation system.
Feature 29Interrupt operation on the input side to speed detection of an event communication back to the panel
Feature 30Group activation on the output to speed up actions on the outputs
Feature 31Address range for sensors S1-S99 – address range for modules M1-M99.
Feature 32Wide range of addressable devices available.
Manufacturer part number / seriesMMX-4000
Tags onlyit accepts all languages supported by Windows 10 (requires graphic annunciator)

Documents & Technical Downloads

Simplex 4007-9201 (Fire Alarm Control Panel)

Simplex 4007-9201 (Fire Alarm Control Panel)

Indicative Price

from

Simplex 4010-9501 (4010Es Facp 240V)

Simplex 4010-9501 (4010Es Facp 240V)

Indicative Price

from

Simplex 4010-9502 (4010Es Facp 240V Red)

Simplex 4010-9502 (4010Es Facp 240V Red)

Indicative Price

from