RAEGuard 2 PID Gas Detector
Flame Detectors

RAEGuard 2 PID Gas Detector

Notifier·SKU: RAEGuard2PID

A fixed gas detector using photoionization (PID) that monitors a broad range of volatile organic compounds

Request a quote

Description

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs)

Product Overview:

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.

The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.

Features & Benefits:

  • Faster response time - Thanks to the sample flow-through design
  • Reduce maintenance cost - Easy to remove sensor module in hazardous locations without using of tools
  • No false alarms - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution

Quick Specs:

  • Digital Smart Sensor Technology
  • Detection range 0.01 to 100 ppm, 0.1 to 1000 ppm, or 1 to 1000 ppm
  • Operates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal output
  • Graphic display and LED light status indicator for fault and alarm conditions

Fire and Gas Consultancy Services

Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Official manufacturer product information

Additional manufacturer specifications

  • Features & Benefits: Accurate Readings; Continuous VOC Monitoring in Hazardous and Non-Hazardous Locations; Easy to Remove Sensor Module in Hazardous Locations without Use of Tools; Fast Speed of Response Provides Earliest Warning; Reduced Life Cost
  • Application: Acetone, Xylene, Phenol in Medical, Pathology, Histology Lab; Air Quality; Ammonia in Industry; Benzene in Refinery Analyser Shelters; Heat Transfer Fluids; Methyl Ethyl Ketone in Paint Spray Booths; Solvent and Chemicals Storage; Toluene in Printing; Toluene or Ammonia in Semi-Conductor Plants; Vinyl Chloride in Chemical Manufacturing

Technical Specifications

Alarm IncludedYes
Analog Output Connection3-Wire
Analog Output Signal Current4 to 20 mA
Analog Output Signal Voltage0.5 to 2.5 V
Analog Outputs4 to 20 mA
BrandRAE
CalibrationAutomatic, Fresh Air
Calibration GasIsobutylene
Calibration Points2
Calibration ProceduresZero and Span Low, Zero, Span Low and Span High
Default Relay ActivationLow, High, Fault
DimensionL: 10.1 in W: 7.9 in H: 4.2 in
Display IncludedYes
Display TypeLCD
Display Viewing Area128 x 64
Drift10
Field of View120° Cone of Vision
Filter IncludedYes
Filter Insert MaterialPTFE
Filter RequiredYes
Filter TypeCoalescing
Humidity Range0 to 95% RH (Non-Condensing)
IndustryEnergy
Ingress ProtectionIP65
Inlet Connector Thread0.75 in
Material316 Stainless Steel
Maximum Analog Input Supply Current110
Maximum Operating Current210 mA
Maximum Pressure110 kPa
Minimum Temperature-20°C
MountingWall
Mounting Thread3/4 in NPT
Number of Analog Outputs1
Number of Contacts3
Number of Digital Communication Ports1
Number of Relay Outputs3
Number of Signal Outputs1
Operating Life2
Operating Voltage10 to 28 VDC
Power Consumption< 5W
Power Requirement24 VDC
Relay Circuit Resting ConfigurationNO, NC
Relay Rated Load30 VDC, 2A
Replacement PartsDigiPID Sensor Module, Lamp
Sampling Pump IncludedYes
Sampling Pump LocationInternal
Sensing MethodPID
SensitivityAdjustable Between 60 ft, 45 ft, 30 ft, and 15 ft to a 1 sq.ft Gasoline Fire
Sensor MechanismPID
Signal Output3-Wire Signal Output
Spectral SensitivityInfrared: 0.7 to 3.5 Micrometers (SS4-A and SS4-AS Only); Ultraviolet: 185 to 260 Nanometers Wide Band; Visible: 400 to 700 Nanometers (SS4-A and SS4-AS only)
Standards & CertificationsATEX: Ex II 2(1)G, Ex d [ia Ga] IIC T4 Gb
Sub-CategoryGas Detection Sensors & Transmitters; Gas Detection Sensors & Transmitters
VibrationMeets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
Warranty1 Year for the Pump; 2 Years for the Housing and Electronics
Weight range3.5 Kg
Wireless TechnologyMesh