24 Volt 1 Amp Power Supply
Fire Alarm Power Supply Units

24 Volt 1 Amp Power Supply

protec·SKU: 9100EN/1A

High Efficiency (Reduces Power Bills and Carbon Footprint); High reliability; Cost effective switch mode technology; Intelligent Battery Charging Monitoring; Deep Discharge Protection; Remote Fault Monitoring; Full Rated Load Plus Additional Current for battery charging; Approved to the Latest...

Request a quote

Description

The Protec 9100EN 1A/ 24 volts switch mode power supply has been designed for use in building fire systems and access control applications. This power supply is fully compliant and approved to the latest EN54 Part 4.

The 9100EN includes intelligent battery charging, mains and battery monitoring with a volt free relay contact fault output for remote monitoring.

The 9100EN output features electronic short circuit protection under both mains and standby battery operation.

Maximum battery life is assured through continuous active battery monitoring and the use of an intelligent charger with temperature compensated final float phase depending upon battery condition.

Deep discharge protection prevents premature battery failure when operating from standby for extended periods.

The inclusion of LED status indicators provides quick diagnostics to the user and/ or engineer.

The 9100EN power supply is capable of charging a battery up to 2 x 12V 3.3Ah capacity.

Official Protec product information

Technical Specifications

Ambient Temperature Limits-5 to 50°C
Battery Charge Current250mA (± 25mA)
Battery Charge Voltage27.3V at 20°C. Temperature compensated at – 40mV °C. Protected by 1.6A self resetting thermal fuse.
Battery Low Voltage Cut-off Level18.5V dc Battery Voltage (outputs turn off)
Battery MonitoringCharger dip, battery load and internal impedance
Battery Over Voltage Fault Level28.5V dc (nominal)
Battery Protection1.6A Self resetting ‘fuse’
Battery Type2 x 12V 2.2Ah Sealed Lead Acid (connected in series) Dimensions: 66 x 134 x 67mm ±1mm
Battery Under Voltage Fault Level22V dc (nominal)
BrandProtec
Current taken from the standby batteries during mains failLess than 150µA ( 9100EN is turnde off )
EnvironmentalDesigned to meet IP30
Fault Relay ContactMaximum rating of 1A at 24V DC (resistive load)
Humidity Limits90% (non-condensation or icing)
Mains Input Fuse (FS1)1.6A time delay (not user or engineer replaceable)
Max Alarm Load, Imax_b1A (batteries not charging)
Max Inrush Current20A at 240V from cold
Max Quiescent Load, Imax_a750mA (batteries charging)
Maximum Battery Resistance (Ri)2Ω (battery internal resistance + lead and connection resistances)
Minimum Load, Imun, panel only5mA
Output Ripple Voltage400mV maximum (peak to peak) at full output load
Output Voltage Range24 – 29V dc with mains present, 17 – 29V dc on batteries
Rated Current600mA rms
Rated Frequency50 to 60 Hz
Rated Voltage85 – 264V ac rms