3502 2 Zone Conventional Fire Alarm Control Panel
Available in 2, 4 and 8 zone models; Attractive surface or recessed mounting; Comprehensive range of engineering functions; Zone disablements; Ability to differentiate between Manual Call Point or automatic detector alarm; Programmable sounders for automatic and/or manual activation 72 Hour...
Request a quoteDescription
The Protec 3500 range of conventional control panels has been designed to provide a simple, user-friendly, highly cost effective option with inbuilt flexibility previously only found in more complex addressable systems.
With 2 detection zones the 3502 Fire Alarm control panel is ideal for small sized buildings such as industrial units, retail units, shops and schools.
The panel can be either surface or recessed mounted, with the controls and indications protected from unauthorised access by entering a user access code. These panel has the ability to identify if a ‘FIRE’ signal has been generated manually by a person activating a Manual Call Point (MCP) or automatically from a detector. This knowledge enables an appropriate cause and effect sequence to be implemented (time delays, for example) to allow for alarm verification for automatic detectors, but immediate alarms from MCPs. Cause and effect functions include coincidence detection, zone delays, pulsing sounders and fire relay. Interconnection with other systems is simplified as zones can be configured as ‘non-latching’, and there is a dedicated ‘class change input’ terminal. The 3502 control panel are third party approved to the latest European standard and meets all the requirements of BS5839 pt1.
Technical Specifications
| Alarm Circuits EOL Value | 10kΩ ±5% ¼W |
|---|---|
| Auxiliary 24V output | 24V dc, 150mA max |
| Battery Fuse | 1.6A resettable fuse |
| Brand | Protec |
| Class Change Input | Activates alarm outputs |
| Current Consumption | 22mA (24V DC) + Zone Load |
| Detector Circuit EOL Values | Resistive(8.2Ω) or capacitive (100µF+22Ω) |
| Dimensions (mm) | 228(W) x 345(H) x 111(D) |
| Global Fault Contacts | 24V DC 1 A rating |
| Global Fire Contacts | 24V DC 1 A rating |
| Humidity Limit | 95% Non-Condensing |
| Integral Charger | 600mA |
| Mains Fuse | 16A time delay (not replaceable) |
| Max Number of Detectors | 25 per zone (smoke or heat) |
| Max Quiescent Zone Load | 5mA per zone |
| Max Zone Cable Capacitance | 0.25µF |
| Max Zone Cable Length | 500 metres |
| Max Zone Cable Resistance | 15Ω per conductor |
| Maximum Alarm Load | 400mA per circuit |
| Maximum Battery Size | 2 x 12V 3.3Ah |
| Maximum Number of Devices | 32 (MCP and Dets) per zone |
| MCP Series Resistor Values | 180Ω ±5% |
| Number of Alarm Circuits | 2 |
| Number of Detector Zones | 2 |
| Power Supply Mains | 100V-240V ac |
| Temperature Range | -5 to 40°C |
| Working Voltage | 18V to 30V DC |
Documents & Technical Downloads
Related Products
View Cataloguearrow_forward
Simplex 4007-9202 (4007ES FACP, IDNAC)
Indicative Price
from

Simplex 4004-9302 (Suppression Releasing Panel)
Indicative Price
from

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)
Indicative Price
from

Simplex 4007-9102 (Fire Alarm Control Panel)
Indicative Price
from