Waterflow Switches
Potter Amseco VSR-C-3 Waterflow Alarm Switch for 3" Copper Pipe for 3-inch Steel Pipe, with Retard, SPDT Contact(s)
Potter / Amseco·SKU: VSR-C3
Indicative Price
Excluding local taxes and shipping.
The Potter Electric VSR-C-3 is a vane-type waterflow switch for use on wet sprinkler systems. It is UL Listed for use on Type K, L, and M 3" copper pipe. The VSR-C-3 may also be used as a sectional waterflow detector on large systems. The VSR-C-3 contains two single poles, double throw, snap action
infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.
Description
The Potter Electric VSR-C-3 is a vane-type waterflow switch for use on wet sprinkler systems. It is UL Listed for use on Type K, L, and M 3" copper pipe.
The VSR-C-3 may also be used as a sectional waterflow detector on large systems.
The VSR-C-3 contains two single poles, double throw, snap action switches, and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period.
For use with wet sprinkler systems, the Model VSR is a water flow switch of the vane type. For use on steel pipe, schedules 10 through 40, diameters 2" through 8," it is UL Listed and FM Approved (50 mm thru 200 mm). Sizes from 2" to 8" are LPC authorized (50 mm thru 200 mm).
On large systems, the VSR can also be employed as a sectional waterflow detector. Two single poles, double throw, snap action switches and an instantaneously recycling pneumatic retard are included in the VSR. When a flow of 10 GPM (38 LPM) or more takes place downstream of the device, the switches are activated. To overcome the chosen retard period, the flow state must endure for the amount of time required.
A general-purpose, die-cast enclosure houses the VSR switches and the retard device. Two tamper-resistant screws that need a unique key to remove hold the cover in place. As an extra, there is a field-installable cover tamper switch that can be used to signal unlawful cover removal.
UPC: 785192015932
Also known as: PL-VSRC3, VSRC3
The VSR-C-3 may also be used as a sectional waterflow detector on large systems.
The VSR-C-3 contains two single poles, double throw, snap action switches, and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period.
For use with wet sprinkler systems, the Model VSR is a water flow switch of the vane type. For use on steel pipe, schedules 10 through 40, diameters 2" through 8," it is UL Listed and FM Approved (50 mm thru 200 mm). Sizes from 2" to 8" are LPC authorized (50 mm thru 200 mm).
On large systems, the VSR can also be employed as a sectional waterflow detector. Two single poles, double throw, snap action switches and an instantaneously recycling pneumatic retard are included in the VSR. When a flow of 10 GPM (38 LPM) or more takes place downstream of the device, the switches are activated. To overcome the chosen retard period, the flow state must endure for the amount of time required.
A general-purpose, die-cast enclosure houses the VSR switches and the retard device. Two tamper-resistant screws that need a unique key to remove hold the cover in place. As an extra, there is a field-installable cover tamper switch that can be used to signal unlawful cover removal.
UPC: 785192015932
Also known as: PL-VSRC3, VSRC3
Technical Specifications:
|
- Non-corrosive saddle bushing
- Two 1/2” KOs for dual voltage applications
- Listings: UL, CSFM, and NYBSA
- 5-year warranty
- 3” pipe size for type K, L, and M copper pipe
- NEMA 4 solid metal enclosure
- Factory installed neoprene gasket
- 0-90 second pneumatic retard
- 175 psi system pressure rated
Technical Specifications
| Brand | Potter / Amseco |
|---|---|
| Contact Ratings | Two sets of SPDT (Form C): 10.0 Amps at 125/250VAC, 2.0 Amps at 30VDC Resistive, 10 mAmps min. at 24VDC |
| Flow Sensitivity Range for Signal | 4-10 GPM (15-38 LPM) - UL |
| Listings | UL, CSFM, and NYBSA |
| Manufacturer Part Number | VSR-C3 |
| Maximum Surge | 18 FPS (5.5 m/s) |
| Service Pressure | 175 PSI (12,1 BAR) - UL |
Documents & Technical Downloads
Related Products
View Cataloguearrow_forward
Potter / Amseco FSBS Flowswitch Bypass Switch
Indicative Price
from

Potter Amseco RD13-100-0 Fire Alarm System Accessory
Indicative Price
from

Potter Amseco RD13-1.5 Residential Riser without Check Valve, 1.5" Pipe
Indicative Price
from

Potter Amseco RD13-1.25 Residential Riser without Check Valve, 1.25" Pipe
Indicative Price
from