The Potter Amseco VSR-8 is an 8-inch vane-type waterflow alarm switch with adjustable pneumatic retard , designed to detect sprinkler water movement in wet-pipe fire protection systems. Featuring two SPDT Form C switches, a 4-10 GPM flow sensitivity range, and a field-adjustable 0-90-second retard ,

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The Potter Amseco VSR-8 is an 8-inch vane-type waterflow alarm switch with adjustable pneumatic retard, designed to detect sprinkler water movement in wet-pipe fire protection systems. Featuring two SPDT Form C switches, a 4-10 GPM flow sensitivity range, and a field-adjustable 0-90-second retard, it provides alarm signaling while reducing nuisance activations caused by pressure surges. The VSR-8 is rated for 450 PSI service pressure and installs on 8-inch Schedule 10-40 steel pipe. Its NEMA 4/IP54 weather-resistant enclosure supports indoor and outdoor applications and carries UL, cUL, and FM approvals.

Potter Amseco VSR-8 Vane-Type Waterflow Alarm Switch with Retard for 8-Inch Sprinkler Pipe

The Potter Amseco VSR-8 Waterflow Alarm Switch provides automatic detection of water movement in wet-pipe fire sprinkler systems using 8-inch (DN200) steel piping. Manufactured by Potter Electric Signal Company, this paddle-operated supervisory device activates its electrical alarm contacts when sustained sprinkler waterflow reaches the required detection threshold. The VSR-8 features two independent SPDT snap-action switches and an adjustable pneumatic retard mechanism, allowing connection to compatible fire alarm control panels, central station signaling equipment, and local notification devices. It is UL Listed and FM Approved for 8-inch Schedule 10 through Schedule 40 steel pipe. Applications include commercial sprinkler risers, industrial facilities, warehouses, institutional buildings, and sectional waterflow monitoring in larger fire protection systems.

The VSR-8 provides a UL-listed flow sensitivity range of 4-10 gallons per minute (15-38 LPM), with manufacturer instructions specifying a minimum test flow of 10 GPM (38 LPM) for reliable activation. Its field-adjustable pneumatic retard provides approximately 0-90 seconds of delay, allowing installers to minimize unwanted alarms from temporary water movement, pressure fluctuations, or trapped air. The retard mechanism resets automatically when waterflow stops before the selected delay expires. The switch is rated for 450 PSI (31 bar) service pressure and a maximum water surge velocity of 18 feet per second (5.5 m/s). A factory-installed non-corrosive saddle insert isolates the sensing assembly from direct metal-to-water contact, while the replaceable vane and retard/switch assembly support maintenance of the installed device.

For fire alarm system integration, the Potter VSR-8 incorporates two independent Form C (SPDT) contacts, each providing common, normally open, and normally closed connections. The manufacturer specifies contact ratings of 10A at 125/250 VAC or 2A at 30 VDC resistive, with a minimum switching current of 10 mA at 24 VDC. One contact set can signal a compatible fire alarm initiating circuit or central monitoring system, while the second can operate a separately powered local alarm or remote annunciator. The enclosure includes two 1/2-inch conduit knockouts and separated switch wiring compartments to accommodate circuits with different voltage requirements. Its weather-resistant composite cover is secured by two tamper-resistant screws, and an optional 0090148 cover tamper switch kit provides supervision of unauthorized cover removal.

The VSR-8 mounts to horizontal or vertical 8-inch steel sprinkler piping using its saddle assembly and U-bolt mounting hardware. The specified pipe outside diameter is 8.625 inches (219.1 mm), with a required installation opening of 2 inches 1/8 inch (50.8 2 mm). On horizontal piping, the device must be mounted on top of the pipe, with the saddle's directional arrow aligned with water movement. Potter requires installation at least 6 inches from fittings that change flow direction and 24 inches from valves or drains. The NEMA 4/IP54 enclosure permits indoor or outdoor installation with appropriate conduit fittings, within a rated ambient temperature range of 40 F to 120 F (4.5 C to 49 C). The VSR-8 is documented for applications governed by NFPA 13, NFPA 13D, NFPA 13R, and NFPA 72, with applicable UL, cUL, FM, and LPCB approvals. The field-replaceable retard/switch assembly, stock number 1029030, supports servicing without removing the complete switch from the pipe. Installation, inspection, and flow testing must follow Potter's instructions and applicable fire protection requirements.



UPC: 785192012832
Also known as: PL-VSR8, VSR8

Technical Specifications:
  • Conduit Entrances: Two knockouts provided for 1/2" conduit
  • Contact Ratings: Two sets of SPDT (Form C), 10.0 Amps at 125/250VAC, 2.0 Amps at 30VDC Resistive, 10 mAmps min. at 24VDC
  • Maximum Surge: 18 FPS (5.5 m/s)
  • Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL
  • Service Pressure: 450 PSI (31 BAR) - UL


  • 0-90 second pneumatic retard
  • 450 psi system pressure rated
  • Synchronized switch action
  • No water to metal contact, eliminates any corrosion possibility
  • Separate isolated wiring chambers eliminate NEC questions regarding multi-voltage applications
  • Five year warranty (One year warranty on 10”)
  • Two ½” KOs for dual voltage applications
  • Pipe schedules 10-40, size 8”
  • NEMA 4 solid metal enclosure
  • Factory installed neoprene gasket
  • Visual switch activation
  • Field replaceable switches
  • Listings: UL, cUL, FM, CSFM, and NYMEA
  • Field replaceable retard

Supplier product information

Technical Specifications

BrandPotter / Amseco
Conduit EntrancesTwo knockouts provided for 1/2" conduit
Contact RatingsTwo sets of SPDT (Form C), 10.0 Amps at 125/250VAC, 2.0 Amps at 30VDC Resistive, 10 mAmps min. at 24VDC
Flow Sensitivity Range for Signal4-10 GPM (15-38 LPM) - UL
ListingsUL, cUL, FM, CSFM, and NYMEA
Manufacturer Part NumberVSR-8
Maximum Surge18 FPS (5.5 m/s)
Service Pressure450 PSI (31 BAR) - UL
UPC785192012832

Documents & Technical Downloads

Potter / Amseco FSBS Flowswitch Bypass Switch

Potter / Amseco FSBS Flowswitch Bypass Switch

Indicative Price

from

Potter Amseco RD13-100-0 Fire Alarm System Accessory

Potter Amseco RD13-100-0 Fire Alarm System Accessory

Indicative Price

from

Potter Amseco RD13-1.5 Residential Riser without Check Valve, 1.5" Pipe

Potter Amseco RD13-1.5 Residential Riser without Check Valve, 1.5" Pipe

Indicative Price

from

Potter Amseco RD13-1.25 Residential Riser without Check Valve, 1.25" Pipe

Potter Amseco RD13-1.25 Residential Riser without Check Valve, 1.25" Pipe

Indicative Price

from