Potter Amseco TTS-S Tank Temperature Switch, Steel
Sprinkler Supervisory Switches

Potter Amseco TTS-S Tank Temperature Switch, Steel

Potter / Amseco·SKU: TTS-S

Indicative Price

Excluding local taxes and shipping.

The Potter Amseco TTS-S is a water tank temperature supervisory switch designed to monitor high and low water temperatures in steel fire protection storage tanks . The device features two independent bimetallic thermostats factory-preset to activate at 40 F (4.5 C) for low-temperature conditions and

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The Potter Amseco TTS-S is a water tank temperature supervisory switch designed to monitor high and low water temperatures in steel fire protection storage tanks. The device features two independent bimetallic thermostats factory-preset to activate at 40 F (4.5 C) for low-temperature conditions and 140 F (60 C) for high-temperature conditions, with an operating tolerance of 5 F ( 3 C). When either temperature threshold is reached, the normally closed supervisory circuit opens to signal an abnormal condition to compatible fire alarm or supervisory monitoring equipment. The TTS-S incorporates a built-in diode for polarity-reversal circuit testing, contacts rated at 0.15 A at 115 VDC, and a 1-inch standard pipe-thread connection for installation through the wall of a steel water tank. Measuring approximately 2.5 inches in diameter and 17.5 inches in length, the switch provides direct temperature supervision of stored water used in fire sprinkler and other water-based fire protection systems. The TTS-S is UL and cUL Listed, FM Approved, and CSFM Listed, making it suitable for commercial, industrial, and institutional fire protection installations requiring supervised water storage temperature monitoring.

Potter Amseco TTS-S Water Tank Temperature Supervisory Switch for Steel Fire Protection Tanks

The Potter Amseco TTS-S Tank Temperature Supervisory Switch provides automatic monitoring of water temperature in steel storage tanks used for fire sprinkler systems and other water-based fire protection applications. Designed to identify potentially hazardous temperature conditions, the TTS-S continuously supervises stored water through two independent temperature-sensitive switching elements. The device is factory-configured to detect both low water temperatures that could indicate freezing conditions and excessively high temperatures that may compromise normal fire protection system operation. By providing an electrical supervisory signal when either threshold is reached, the switch enables compatible fire alarm control panels and supervisory monitoring equipment to identify abnormal tank conditions so corrective action can be taken. Typical applications include commercial buildings, industrial facilities, warehouses, institutional properties, and other sites relying on dedicated fire protection water storage tanks.

The TTS-S incorporates two separate bimetallic thermostats, providing independent temperature supervision at predetermined operating points. The low-temperature thermostat is preset to 40 F (4.5 C), while the high-temperature thermostat is preset to 140 F (60 C), with a manufacturer-specified tolerance of 5 F ( 3 C). Under normal water temperature conditions, both thermostat contacts remain closed, maintaining continuity through the supervisory circuit. When the water temperature reaches either operating threshold, the corresponding thermostat opens, interrupting circuit continuity and allowing connected supervisory equipment to detect the abnormal condition. The factory-established temperature settings eliminate the need for field adjustment and provide consistent monitoring of both lower and upper water temperature limits.

For electrical supervision and troubleshooting, the Potter TTS-S features an integrated diode that supports polarity-reversal testing of the switch and associated field wiring. During normal operation, the device functions as a polarity-sensitive, normally closed contact arrangement. The positive initiating circuit connection must be made to the white lead, while the negative connection must be made to the black lead. Reversing the polarity during the manufacturer's specified test procedure causes the internal diode to block current flow, helping technicians identify wiring faults and verify that a short circuit is not bypassing the supervisory device. When either thermostat reaches its operating temperature, the circuit opens regardless of the applied test polarity. This arrangement supports systematic inspection and troubleshooting of the monitored circuit without requiring complex electronic controls.

The TTS-S is designed specifically for steel water tank installations and includes a 1-inch standard pipe-thread mounting connection that allows the temperature-sensing assembly to extend through the tank wall and into the stored water. According to Potter's installation instructions, installers may weld a No. 282-1 pipe flange to the tank or drill and tap the steel tank wall to receive the threaded mounting bushing. The device should be positioned approximately 24 inches (60 cm) below the required water level to provide the specified sensing location. Its elongated probe assembly places the temperature-sensitive elements within the water being monitored, while the external connection housing remains accessible for electrical wiring and maintenance. The steel-tank configuration is designated TTS-S, while the separately available TTS-W version uses a buttress-thread connection intended for wooden tank installations.

The Potter Amseco TTS-S measures approximately 2.5 inches (63.5 mm) in diameter and 17.5 inches (445 mm) in overall length, providing a compact supervisory device for direct tank-wall installation. The switch includes a 1/2-inch conduit opening for routing field wiring into the external connection housing. Its electrical contacts are rated at 0.15 amperes at 115 VDC, and the device is intended to interface with appropriately rated supervisory or initiating circuits rather than directly control high-current heating equipment. When the TTS-S is installed as the last or only device on an initiating circuit, the manufacturer's instructions require the end-of-line resistor to be connected in series with the switch, using either the black or white lead as appropriate. Correct polarity, circuit configuration, and control panel compatibility must be established according to the manufacturer's wiring diagrams and the requirements of the connected monitoring system.

Routine inspection and functional testing are supported through the switch's straightforward electromechanical design. Potter specifies an ohmmeter testing procedure that uses the internal diode to distinguish normal circuit behavior from open circuits and potential shorts. With the meter's positive lead connected to the white wire and negative lead connected to the black wire, the device produces the manufacturer's specified continuity indication. Reversing the test polarity produces an open-circuit indication under normal conditions. A diode-test function may also be used to evaluate the internal diode response. To confirm actual thermostat operation, the sensing assembly must be exposed to the respective 40 F and 140 F operating temperatures, causing the appropriate thermostat to open. These procedures help maintenance personnel verify the device's electrical integrity and temperature-responsive switching characteristics during scheduled fire protection system inspections.

The Potter TTS-S is UL and cUL Listed, FM Approved, CSFM Listed, and documented as accepted by the New York City Materials and Equipment Acceptance program, supporting its use in regulated fire protection applications subject to applicable approval requirements. Manufacturer ordering information identifies the TTS-S under stock number 1010040, with a separately available 1-inch mounting flange, stock number 5020012, for appropriate steel tank installations. By combining dual-temperature supervision, normally closed electrical contacts, and built-in circuit testing capability, the TTS-S provides a practical means of monitoring fire protection water storage conditions. It is particularly suitable for installations where stored water must be monitored for conditions that could affect sprinkler system readiness. Final device placement, wiring, supervisory circuit compatibility, testing procedures, and installation requirements should be verified against current Potter documentation and applicable fire protection codes before the system is placed into service.



UPC: 785192000341
Also known as: PL-TTSS, TTSS

Technical Specifications:
  • Dimensions: 2 1/2" DIA x 17 1/2"L (63.5mm DIA x 445mm L)


  • Listings: UL, FM, CSFM, and MEA
  • Operates at 40°F and 140°F
  • NEMA 4 enclosure
  • Available for steel tanks

Supplier product information

Technical Specifications

BrandPotter / Amseco
Dimensions2 1/2" DIA x 17 1/2"L (63.5mm DIA x 445mm L)
ListingsUL, FM, CSFM, and MEA
Manufacturer Part NumberTTS-S
UPC785192000341

Documents & Technical Downloads

Potter Amseco OSYSU-1 Outside Screw and Yoke Valve Supervisory Switch, Single Switch

Potter Amseco OSYSU-1 Outside Screw and Yoke Valve Supervisory Switch, Single Switch

Indicative Price

from

Potter Amseco OSYSU-2 OS&Y Valve Supervisory Switch, 2 SPDT

Potter Amseco OSYSU-2 OS&Y Valve Supervisory Switch, 2 SPDT

Indicative Price

from

Potter Amseco PCVS-1 Control Valve Supervisory Switch

Potter Amseco PCVS-1 Control Valve Supervisory Switch

Indicative Price

from

Potter Amseco PCVS-2 Control Valve Supervisory Switch

Potter Amseco PCVS-2 Control Valve Supervisory Switch

Indicative Price

from