Potter Amseco RD13-2 Residential Riser without Check Valve, 2" Pipe
Waterflow Switches

Potter Amseco RD13-2 Residential Riser without Check Valve, 2" Pipe

Potter / Amseco·SKU: RD13-2"

Indicative Price

Excluding local taxes and shipping.

The RD13 Riser (with NPT connectors) is constructed from Listed CPVC products suitable for fire sprinkler services subject to the limitations and installation requirements of Flameguard CPVC pipe and Spears CPVC fittings. The RD13 Riser incorporates a VSR-SG flow switch, gauge, and drain/test valve.

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The RD13 Riser (with NPT connectors) is constructed from Listed CPVC products suitable for fire sprinkler services subject to the limitations and installation requirements of Flameguard CPVC pipe and Spears CPVC fittings. The RD13 Riser incorporates a VSR-SG flow switch, gauge, and drain/test valve. The VSR-SG flow switch is equipped with union connection to facilitate the installation and removal of the switch in confined spaces.


Also known as: RD132

Technical Specifications:
  • Conduit Entrances: Two knockouts provided for 1/2” conduit
  • Environmental Limitations: Temperature range: 40°F-120°F (4.5°C-49°C)-UL
  • Contact Ratings: Two sets of SPDT (Form C), 10.0 Amps at 125/250VAC, 2.0 Amps at 30VDC Resistive10 mAmps min. at 24VDC Resistive, 10 m Amps min. at 24V DC
  • Maximum Surge: 18 FPS (5.5 m/s)
  • Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL
  • Service Pressure: 175 PSI (12,07 BAR) - UL


  • Pre-assembled and pressure tested
  • 2” nominal pipe size
  • Fits in standard 2x4 construction walls
  • Female adapter ships loose so riser can be installed in a confined space

Supplier product information

Technical Specifications

BrandPotter / Amseco
Conduit EntrancesTwo knockouts provided for 1/2” conduit
Contact RatingsTwo sets of SPDT (Form C), 10.0 Amps at 125/250VAC, 2.0 Amps at 30VDC Resistive10 mAmps min. at 24VDC Resistive, 10 m Amps min. at 24V DC
Environmental LimitationsTemperature range: 40°F-120°F (4.5°C-49°C)-UL
Flow Sensitivity Range for Signal4-10 GPM (15-38 LPM) - UL
Manufacturer Part NumberRD13-2"
Maximum Surge18 FPS (5.5 m/s)
Service Pressure175 PSI (12,07 BAR) - UL

Documents & Technical Downloads

Potter / Amseco FSBS Flowswitch Bypass Switch

Potter / Amseco FSBS Flowswitch Bypass Switch

Indicative Price

from

Potter Amseco RD13-100-0 Fire Alarm System Accessory

Potter Amseco RD13-100-0 Fire Alarm System Accessory

Indicative Price

from

Potter Amseco RD13-1.5 Residential Riser without Check Valve, 1.5" Pipe

Potter Amseco RD13-1.5 Residential Riser without Check Valve, 1.5" Pipe

Indicative Price

from

Potter Amseco RD13-1.25 Residential Riser without Check Valve, 1.25" Pipe

Potter Amseco RD13-1.25 Residential Riser without Check Valve, 1.25" Pipe

Indicative Price

from