Potter Amseco PS40-2 Low/High Supervisory Pressure Switch
Indicative Price
Excluding local taxes and shipping.
The Potter / Amseco PS40-2 is a dual-switch supervisory pressure switch with factory-set low-pressure activation at 30 PSI and high-pressure activation at 50 PSI for fire sprinkler systems operating at a nominal 40 PSI . Designed for dry-pipe, pre-action, air, nitrogen, and water pressure supervisio
Description
The Potter / Amseco PS40-2 is a dual-switch supervisory pressure switch with factory-set low-pressure activation at 30 PSI and high-pressure activation at 50 PSI for fire sprinkler systems operating at a nominal 40 PSI. Designed for dry-pipe, pre-action, air, nitrogen, and water pressure supervision, it features two independently adjustable SPDT Form C contacts, a 10-60 PSI adjustment range, and a 300 PSI maximum system pressure rating. Its NEMA 4/IP66 weather-resistant enclosure, 1/2-inch NPT pressure connection, and UL/cUL and FM approvals support professional fire protection installations.
Potter Amseco PS40-2 Dual-Switch High/Low Supervisory Pressure Switch
The Potter / Amseco PS40-2 is a dual-switch supervisory pressure device designed to detect increases and decreases in pressure within automatic fire sprinkler systems. Manufactured by Potter Electric Signal Company, the PS40-2 monitors the condition of pressurized air, nitrogen, or water supplies used in fire protection equipment. The device is particularly suited for dry-pipe and pre-action sprinkler systems, pressure tanks, air supply lines, and other supervised sprinkler system piping. It contains two independent pressure-actuated switches, allowing one electrical circuit to report a low-pressure condition while the other reports a high-pressure condition. The PS40-2 is factory-adjusted for systems operating at a nominal 40 PSI (2.8 bar), with the low-pressure switch set to activate at approximately 30 PSI (2.1 bar) and the high-pressure switch set to activate at approximately 50 PSI (3.5 bar). These separate operating points help identify abnormal pressure conditions before they compromise the intended readiness of the sprinkler system.
The PS40-2 incorporates two independently adjustable single-pole double-throw (SPDT) Form C switches, each providing common, normally open, and normally closed contact functionality. The LOW switch changes state when system pressure decreases to its configured threshold, while the HIGH switch responds when pressure increases to its designated setting. Both switches are independently adjustable over a 10-60 PSI (0.7-4.1 bar) range using knurled adjustment knobs that do not require special adjustment tools. The manufacturer specifies typical switching differentials of approximately 1 PSI at a 10 PSI operating point and 4 PSI at a 60 PSI operating point. Field adjustments allow the switch to accommodate compatible sprinkler systems with normal supervisory pressures other than 40 PSI. Final activation points must be verified using an appropriate pressure gauge and electrical continuity testing. This dual-switch configuration distinguishes the PS40-2 from the single-switch PS40-1, which provides low-pressure supervision only.
The Potter PS40-2 provides two electrically independent SPDT Form C contact sets rated at 10.1 amps at 125/250 VAC or 2.0 amps at 30 VDC. These dry contacts support connection to compatible fire alarm control panels, supervisory monitoring circuits, and other approved signaling equipment. Separate switch compartments and two 1/2-inch conduit entrances allow installers to route wiring for different monitoring circuits while maintaining electrical separation. Its mechanically operated pressure-sensing assembly does not require an independent 12V or 24V power supply to measure pressure; electrical power is associated with the connected monitoring or signaling circuit. A 1/2-inch NPT male nylon pressure connection provides a non-corrosive interface to compatible sprinkler system piping. The device is rated for a maximum system pressure of 300 PSI (20.68 bar), while the selectable switch actuation range remains 10-60 PSI. These ratings support applications requiring supervision of moderate air or nitrogen pressure in systems capable of experiencing significantly higher hydraulic pressure.
The PS40-2 features a weather-resistant, UV-resistant, flame-resistant high-impact composite cover mounted to a corrosion-resistant die-cast base. The enclosure measures approximately 3.78 inches wide, 3.20 inches deep, and 4.22 inches high (96 x 81 x 107 mm) and provides NEMA Type 4/IP66 environmental protection for properly installed indoor and outdoor applications. The manufacturer specifies an operating temperature range of -40 F to 140 F (-40 C to 60 C). The enclosure uses a tamper-resistant cover screw requiring a specialized removal key, with one key supplied with the device. For outdoor installations, appropriately rated NEMA 4 watertight conduit fittings are required to preserve the enclosure's environmental protection. Potter recommends installing the PS40-2 upright with its threaded pressure connection facing downward and connecting it to the system side of applicable shutoff or check valves. The optional Potter BVL bleeder valve allows technicians to isolate and test the pressure switch without changing the supervisory pressure of the complete sprinkler system.
The Potter / Amseco PS40-2 is designed for fire sprinkler pressure supervision in installations governed by NFPA 13, NFPA 13D, NFPA 13R, and NFPA 72. Its independent high- and low-pressure contacts can be connected to compatible fire alarm supervisory inputs to identify changes in air or nitrogen pressure associated with leaks, compressor malfunctions, regulator problems, or other abnormal system conditions. The manufacturer identifies the PS40 Series as UL/cUL Listed, Factory Mutual (FM) Approved, LPC Approved, and California State Fire Marshal recognized, with additional regional approvals documented in its technical literature. Installation and testing must follow the approved sprinkler system design, applicable regulations, and the authority having jurisdiction. Potter recommends functional testing upon installation and periodically thereafter, with quarterly testing or more frequent inspection where required. The PS40-2 also supports the optional PSCTSK cover tamper switch kit for applications requiring electrical notification of enclosure access. Combining independent high- and low-pressure supervision, field-adjustable 10-60 PSI setpoints, dual Form C contacts, and NEMA 4/IP66 construction, the PS40-2 provides a pressure monitoring solution for commercial, industrial, and residential fire sprinkler systems.
UPC: 785192013709
Also known as: PL-PS402, PS402
Technical Specifications:
|
- Factory set for operation at: Pressure Increase at 50 psi, Pressure Decrease at 30 psi
- Two ½” knockouts for dual voltage applications
- Two sets of SPDT contacts
- NEMA 4 solid metal enclosure
- Factory installed neoprene gasket
- Pressure range 10-60 psi
- 300 psi system pressure rated
- ½” male NPT fitting
- Independent switch adjustment allows easy adjustment of one switch without affecting the other switch
- Separate isolated wiring chambers eliminate NEC questions regarding multi-voltage applications
- Listings: UL, cUL, CSFM, FM, LPC, NYMEA, and CE
- 5-year warranty
Technical Specifications
| Brand | Potter / Amseco |
|---|---|
| Conduit Entrance | Two knockouts provided for 1/2" conduit. Individual switch compartments and ground screw suitable for dissimilar voltages |
| Differential | Typical 1 lb. at 10 PSI (.07 at .7 BAR), 4 lbs at 60 PSI (.28 at 4.1 BAR) |
| Enclosure | Cover- Die-cast with textured red powdercoat finish, single cover screw and rain lip; Base- Die-cast |
| Factory Adjustment | Operates on increase at 50 PSI (3.5 BAR) and on decrease at 30 PSI (2.1 BAR) |
| Factory set for operation at | Pressure Increase at 50 psi, Pressure Decrease at 30 psi |
| Listings | UL, cUL, CSFM, FM, LPC, NYMEA, and CE |
| Manufacturer Part Number | PS40-2 |
| Maximum System Pressure | 300 PSI (20,68 BAR) |
| Pressure Connection | Nylon 1/2" NPT male |
| Pressure Range | 10-60 PSI (.7 - 4.1 BAR) |
| Switch Contacts | SPDT (Form C), 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC, Two SPDT |
| UPC | 785192013709 |
Documents & Technical Downloads
Related Products
View Cataloguearrow_forward
Potter / Amseco IFSSWPS
Indicative Price
from

Potter / Amseco IFSS-1
Indicative Price
from

Potter Amseco BVL Lever Type Bleeder Valve
Indicative Price
from