The Macurco OX-6 is a low voltage, dual relay Oxygen (O2) detector, controller and transducer. The OX-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of Oxygen and provide feedback and automatic exhaust fan c
infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.
Description
The Macurco OX-6 is a low voltage, dual relay Oxygen (O2) detector, controller and transducer. The OX-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of Oxygen and provide feedback and automatic exhaust fan control to help maintain appropriate Oxygen concentrations in commercial applications. The OX-6 is a low level meter capable of detecting from 0-25% by volume of Oxygen.
The OX-6 is also available in White.
UPC: 783748834907
Also known as: OX6
The OX-6 is also available in White.
UPC: 783748834907
Also known as: OX6
Technical Specifications:
|
- ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
- Dark gray housing
- Fan relay actuation: selectable at 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
- Output: Fan relay, Alarm relay and 4-20mA current loop
- Controls: Digital display (0-25% v/v), buzzer, fan delay, fan minimum runtime
- Mounts on a standard 4” x 4” electrical box
- 5 A SPDT fan relay controls valves, louvers or exhaust fans
- 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
- 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
- Factory calibrated
- Supervised system design: detector problem will cause the fan & alarm relay to activate
- Optional calibration test kit allows the OX-6 to be field calibrated and tested
Technical Specifications
| Alarm relay | 0.5A 120 V, 60 VA |
|---|---|
| Alarm relay actuation | selectable N.O. default or N.C. |
| Alarm relay settings | OFF, 18.5, 19, 19.5 (default), 20, 20.5 and high 23.5 % v/v (preset) |
| Brand | Macurco |
| Color | Dark gray |
| Connections | plugs/terminals |
| Controls | Digital display (0-25% v/v), buzzer, fan delay, fan minimum runtime |
| Current @ 24 VDC | 75 mA in alarm, 50 mA fan relay on and 23 mA stand by |
| Fan relay | 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching |
| Fan relay actuation | selectable at 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset) |
| Manufacturer Part Number | OX-6 |
| Mounting box | (not included) 4x4 electric |
| Operating Environment | 0°F to 125° F (-18°C to 52°C),10 to 90% RH non-condensing |
| Output | Fan relay, Alarm relay and 4-20mA current loop |
| Power | 3 W (max) from 12 to 24 VAC or 12 to 32 VDC |
| Shipping Weight | 1 pound (0.45 kg) |
| Size | 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm) |
| Supervised system design | detector problem will cause the fan & alarm relay to activate |
| UPC | 783748834907 |