Macurco OX-6 0-25% Low-Voltage Oxygen Gas Detector
Gas Detectors

Macurco OX-6 0-25% Low-Voltage Oxygen Gas Detector

Macurco·SKU: OX-6

Indicative Price

Excluding local taxes and shipping.

The Macurco OX-6 is a low voltage, dual relay Oxygen (O2) detector, controller and transducer. The OX-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of Oxygen and provide feedback and automatic exhaust fan c

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The Macurco OX-6 is a low voltage, dual relay Oxygen (O2) detector, controller and transducer. The OX-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of Oxygen and provide feedback and automatic exhaust fan control to help maintain appropriate Oxygen concentrations in commercial applications. The OX-6 is a low level meter capable of detecting from 0-25% by volume of Oxygen.

The OX-6 is also available in White.

UPC: 783748834907
Also known as: OX6

Technical Specifications:
  • Operating Environment: 0°F to 125° F (-18°C to 52°C),10 to 90% RH non-condensing
  • Alarm relay settings: OFF, 18.5, 19, 19.5 (default), 20, 20.5 and high 23.5 % v/v (preset)
  • Alarm relay actuation: selectable N.O. default or N.C.
  • Alarm relay: 0.5A 120 V, 60 VA
  • Current Loop, 4-20 mA for 0-25% v/v O2
  • Fan Minimum Runtime settings are OFF (default), 3, 5, 10 or 15 minutes
  • Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutes
  • Fan relay actuation: selectable at OFF, 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
  • Fan relay: 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
  • Mounting box: (not included) 4x4 electric
  • Connections: plugs/terminals
  • Color: Dark gray
  • Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
  • Shipping Weight: 1 pound (0.45 kg)
  • Current @ 24 VDC: 75 mA in alarm, 50 mA fan relay on and 23 mA stand by
  • Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC


  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
  • Dark gray housing
  • Fan relay actuation: selectable at 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Digital display (0-25% v/v), buzzer, fan delay, fan minimum runtime
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT fan relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Factory calibrated
  • Supervised system design: detector problem will cause the fan & alarm relay to activate
  • Optional calibration test kit allows the OX-6 to be field calibrated and tested

Supplier product information

Technical Specifications

Alarm relay0.5A 120 V, 60 VA
Alarm relay actuationselectable N.O. default or N.C.
Alarm relay settingsOFF, 18.5, 19, 19.5 (default), 20, 20.5 and high 23.5 % v/v (preset)
BrandMacurco
ColorDark gray
Connectionsplugs/terminals
ControlsDigital display (0-25% v/v), buzzer, fan delay, fan minimum runtime
Current @ 24 VDC75 mA in alarm, 50 mA fan relay on and 23 mA stand by
Fan relay5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuationselectable at 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
Manufacturer Part NumberOX-6
Mounting box(not included) 4x4 electric
Operating Environment0°F to 125° F (-18°C to 52°C),10 to 90% RH non-condensing
OutputFan relay, Alarm relay and 4-20mA current loop
Power3 W (max) from 12 to 24 VAC or 12 to 32 VDC
Shipping Weight1 pound (0.45 kg)
Size4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
Supervised system designdetector problem will cause the fan & alarm relay to activate
UPC783748834907