Macurco GD-12 Combustible Gas Detector, 100-240VAC
Indicative Price
Excluding local taxes and shipping.
The Macurco GD-12 is a commercial-grade, line-voltage combustible gas detector, controller, and transducer designed to monitor hazardous concentrations of methane (natural gas), propane (LP), or hydrogen in enclosed commercial environments. Part of the Macurco 12 Series , the GD-12 operates on 100-2
Description
The Macurco GD-12 is a commercial-grade, line-voltage combustible gas detector, controller, and transducer designed to monitor hazardous concentrations of methane (natural gas), propane (LP), or hydrogen in enclosed commercial environments. Part of the Macurco 12 Series, the GD-12 operates on 100-240 VAC, 50/60 Hz and uses a catalytic gas sensor to measure combustible gas concentrations from 0-50% of the Lower Explosive Limit (LEL). The detector features a 5A SPDT ventilation control relay, 0.5A configurable alarm relay, 4-20 mA analog output, three-digit LED display, and selectable 85 dBA audible buzzer. Adjustable alarm thresholds and automatic fan control allow integration with exhaust ventilation systems, gas shutoff equipment, fire/security control panels, and building automation systems. ETL listed to UL 61010-1 and CAN/CSA C22.2 No. 61010-1, the GD-12 is designed for parking garages, mechanical rooms, battery charging facilities, warehouses, and commercial buildings requiring continuous combustible gas monitoring.
Macurco GD-12 Combustible Gas Detector and Ventilation Controller, 100-240 VAC
The Macurco GD-12 Combustible Gas Detector provides continuous monitoring and automatic control of ventilation and warning equipment in commercial facilities where combustible gas accumulation presents a safety concern. Manufactured by Macurco Gas Detection as part of its 12 Series, the GD-12 combines combustible gas sensing, configurable alarm outputs, ventilation relay control, and analog gas concentration reporting within a single wall-mounted device. The detector can be configured to monitor methane (CH4), propane (C3H8), or hydrogen (H2), making it suitable for natural gas mechanical rooms, propane storage applications, battery charging areas, parking garages, maintenance facilities, and warehouses using fuel-powered equipment. Its integrated electronic controller monitors gas concentrations and activates connected exhaust fans, louvers, warning devices, or external control systems when user-defined thresholds are reached. The GD-12 supports standalone operation or integration with compatible Macurco ventilation control panels, fire/security monitoring equipment, and building automation systems.
The Macurco GD-12 uses a catalytic combustible gas sensor with a measurement and display range of 0-50% LEL, providing early indication of potentially hazardous gas accumulation before concentrations reach the lower explosive limit. Its internal switching power supply accepts 100-240 VAC at 50/60 Hz, with a maximum input current of 1.0 amp, eliminating the need for a separate low-voltage transformer. The unit incorporates a 5A SPDT fan control relay rated for 240 VAC pilot-duty operation and a separate 0.5A alarm relay rated for 120 VAC, supporting independently configured ventilation and alarm functions. A selectable 4-20 mA current loop output represents combustible gas concentrations across the detector's 0-50% LEL monitoring range, allowing compatible building automation systems and ventilation controllers to receive proportional gas concentration information. Additional features include a three-digit LED display, configurable 85 dBA audible buzzer measured at 10 cm, and onboard diagnostics for detector fault monitoring. The dark gray housing measures approximately 4-1/2 inches high, 4 inches wide, and 2-1/8 inches deep. The GD-12 operates within an ambient temperature range of 0 F to 125 F (-18 C to 52 C) and 10-90% relative humidity, non-condensing, and is ETL listed to UL 61010-1 and CAN/CSA C22.2 No. 61010-1.
For automated gas detection and ventilation control, the Macurco GD-12 provides independently adjustable fan and alarm activation thresholds to accommodate different combustible gas monitoring applications. The ventilation relay can be configured to activate at gas concentrations from 3% to 20% LEL, with a factory-default setting of 10% LEL, while the alarm relay supports selectable thresholds of 5%, 10%, 15%, 20%, or 25% LEL, with a default alarm setting of 20% LEL. Programmable fan activation delays of 0, 1, 3, 5, or 10 minutes and minimum fan runtime settings of 0, 3, 5, 10, or 15 minutes allow installers to coordinate ventilation operation with facility requirements. The fan relay also supports selectable latching and non-latching behavior, while the alarm relay can be configured for normally open or normally closed operation. The detector's 4-20 mA analog signal supports integration with compatible building management systems, variable-frequency drives, and Macurco DVP-120 ventilation control equipment. Its supervisory functions provide fault indication and configurable relay responses to internal detector problems, helping maintenance personnel identify conditions that could affect gas monitoring performance.
Installation of the Macurco GD-12 line-voltage gas detector uses a standard 4-inch by 4-inch electrical junction box, with the detector housing serving as the front cover of the mounting assembly. Placement depends on the selected target gas and the physical characteristics of the monitored environment, including ventilation patterns, potential leakage sources, and gas density. Methane and hydrogen detection generally require elevated sensor placement because these gases are lighter than air, while propane monitoring typically requires installation closer to floor level because propane is heavier than air. The GD-12 is designed for indoor commercial installations and is not approved for hazardous classified locations, including certain industrial refinery and chemical processing environments. The detector features factory calibration, field-adjustable operating parameters, diagnostic monitoring, and accessible calibration and gas testing provisions, allowing qualified technicians to perform scheduled functional verification and maintenance. The catalytic sensor has an expected service life of approximately five years or longer under suitable operating conditions, with end-of-life indication supporting replacement planning. Unlike the Macurco GD-6, which accepts low-voltage AC or DC power, the GD-12 operates directly from a 100-240 VAC line-voltage supply. Combining selectable combustible gas detection, independent alarm and fan relays, analog monitoring output, and programmable ventilation control, the Macurco GD-12 provides an integrated gas safety monitoring solution for commercial mechanical rooms, enclosed parking facilities, battery storage areas, and industrial-support spaces.
UPC: 051135890387
Also known as: MA-GD12, GD12
Technical Specifications:
|
- Mounts on a standard 4” x 4” electrical box
- ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
- Supervised system design: detector problem will cause relay activation
- 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
- 0.5A N.O. or N.C alarm relay connects to warning devices or control panels
- 5A SPDT relay controls valves, louvers or exhaust fans
- 100-240VAC input
Technical Specifications
| Brand | Macurco |
|---|---|
| Certifications & Standards | cETLus Intertek UL 61010-1 Can/CSA C22.2 by ETL |
| Country of Origin | United States |
| Detectable Gas | Hydrogen, Methane, Propane |
| Detectable Medium | Gas |
| Form Factor | Duct Mount, Surface Mount, Wall Mount |
| Input Voltage | 120 V AC, 230 V AC |
| Limited Warranty | 2 Year |
| Manufacturer Part Number | GD-12 |
| Product Color | Gray |
| Product Line | Commercial |
| Product Type | Gas Leak Sensor |
| Status Indicators | Alarm, LED |
| Supervised system design | detector problem will cause relay activation |
| UPC | 051135890387 |
| Weight (Approximate) | 1 lb |
Documents & Technical Downloads
Related Products
View Cataloguearrow_forward
Bosch D382 Combustible Gas Detector, 12/24VAC/DC
Indicative Price
from