Macurco CX-6 Dual CO/NO2 Low Voltage Gas Monitor Controller
Indicative Price
Excluding local taxes and shipping.
The Macurco CX-6 is a dual-gas carbon monoxide (CO) and nitrogen dioxide (NO2) detector with automatic ventilation control, two relay outputs, and a 4-20 mA analog signal for commercial parking garages, loading docks, and vehicle maintenance facilities. Operating on 12-24 VAC or 12-32 VDC, it monito
Description
The Macurco CX-6 is a dual-gas carbon monoxide (CO) and nitrogen dioxide (NO2) detector with automatic ventilation control, two relay outputs, and a 4-20 mA analog signal for commercial parking garages, loading docks, and vehicle maintenance facilities. Operating on 12-24 VAC or 12-32 VDC, it monitors CO concentrations from 0-200 ppm and NO2 from 0-20 ppm. The CX-6 features a 5A SPDT fan relay, configurable 0.5A alarm relay, digital display, internal buzzer, and field-replaceable sensors with a 4-5 year service life. It is ETL Listed to UL 2075.
Macurco CX-6 Dual CO and NO2 Gas Detector with Ventilation Control
The Macurco CX-6 is a low-voltage dual-gas detector, ventilation controller, and analog transducer designed to monitor carbon monoxide (CO) and nitrogen dioxide (NO2) in commercial and light-industrial environments. Part of Macurco's 6 Series fixed gas detection platform, the CX-6 combines two gas sensing functions within a single wall-mounted unit, allowing facilities to monitor hazardous vehicle exhaust gases without installing separate CO and NO2 detectors at every monitoring location. The detector measures carbon monoxide concentrations from 0 to 200 parts per million (ppm) and nitrogen dioxide concentrations from 0 to 20 ppm, providing gas concentration information for automated ventilation and alarm control. The CX-6 is designed for enclosed parking garages, loading docks, vehicle repair shops, bus depots, ambulance bays, and other commercial spaces where combustion engines can generate potentially hazardous exhaust emissions. Macurco specifies a recommended coverage area of up to 7,500 square feet per detector, subject to building geometry, ventilation patterns, sensor placement, and applicable mechanical and building codes.
The Macurco CX-6 operates on 12-24 VAC or 12-32 VDC power, with a maximum power consumption of approximately 3 watts, enabling integration with compatible low-voltage power supplies and gas monitoring systems. At 24 VDC, manufacturer-published current consumption is approximately 23 mA during standby, 50 mA with the fan relay energized, and 75 mA during alarm. The detector incorporates a 5-amp single-pole, double-throw (SPDT) ventilation relay and a separate 0.5-amp alarm relay, providing configurable control of exhaust fan starters, motor control circuits, alarm equipment, and compatible building automation interfaces. User-selectable settings allow technicians to configure ventilation activation thresholds, alarm relay operation, fan delays, and minimum ventilation runtimes according to the facility's operating requirements. A 4-20 mA analog current-loop output provides gas concentration information to compatible Macurco control panels, building management systems, and other monitoring equipment. The CX-6 can operate as a standalone gas detector and ventilation controller or function as part of a larger coordinated gas detection system.
The CX-6 incorporates two field-replaceable gas sensing elements for carbon monoxide and nitrogen dioxide, allowing maintenance personnel to service the individual sensors without replacing the entire monitoring assembly. Macurco specifies an expected sensor service life of approximately 4-5 years for the current CX-6 platform, with end-of-life notification to identify when replacement is required. The detector includes a configurable digital LED display for viewing gas concentration information and an internal audible buzzer for local notification. Its two-button programming interface provides access to supported operating settings, alarm parameters, and diagnostic functions without requiring separate programming software. The enclosure measures approximately 4-1/2 inches high, 4 inches wide, and 2-1/8 inches deep and is designed for installation over a standard 4-inch square electrical box using an appropriate mounting plate. The CX-6 supports a manufacturer-specified operating temperature range of -4 F to +122 F (-20 C to +50 C) and relative humidity from 10% to 90%, noncondensing. Optional accessories include the Macurco MRS-485 communication adapter, WHK-1 weatherproof housing, CM-CH calibration hood, and compatible field calibration equipment. Replacement sensors must be calibrated in accordance with manufacturer instructions following installation.
The Macurco CX-6 is designed for commercial vehicle exhaust monitoring and demand-controlled ventilation systems where both carbon monoxide and nitrogen dioxide concentrations must be measured and managed. Its programmable relay outputs can activate ventilation equipment or auxiliary warning devices when monitored gas levels reach configured thresholds, helping facilities respond to changing air quality conditions while avoiding unnecessary continuous fan operation. The detector's analog output supports integration with compatible building management systems, variable-frequency drive control interfaces, and Macurco gas detection control panels, providing centralized monitoring for larger parking structures and industrial facilities. The CX-6 is ETL Listed to UL 2075 for gas and vapor detector applications, as confirmed by Macurco's updated product certification announcement. Unlike the Macurco CX-6-CO, which monitors carbon monoxide only, or the CX-6-NO2, which monitors nitrogen dioxide only, the standard CX-6 incorporates both sensing functions. The related Macurco CX-12 provides the same dual-gas monitoring concept with 100-240 VAC line-voltage operation instead of low-voltage power. With its dual-gas sensing, replaceable sensors, adjustable ventilation and alarm relays, digital display, and 4-20 mA output, the Macurco CX-6 provides an integrated solution for commercial gas detection and automated exhaust ventilation. The product is backed by a two-year limited manufacturer warranty.
UPC: 857560007495
Also known as: MA-702900013, CX6
Technical Specifications:
|
Technical Specifications
| Brand | Macurco |
|---|---|
| Certifications & Standards | cETLus Intertek UL 61010-1 |
| Country of Origin | United States |
| Input Current | 5 A |
| Input Voltage | 12 V DC, 24 V DC |
| Manufacturer Part Number | CX-6 |
| Product Color | Gray |
| Product Line | Commercial |
| Product Type | Gas Detector Tester |
| UPC | 857560007495 |
Documents & Technical Downloads