Flame Detectors
Li-ion Tamer Multi Output System
Notifier·SKU: LT-SEN-MOS
Li-ion Tamer Multi Output System
Request a quoteDescription
Assembly comprises Li-ion Tamer Gen 2+ sensor and Interface Module. Provides relays, Modbus 485 and CANbus outputs.
Features & Benefits:- Early warning of lithium-ion battery failures
- Enable thermal runaway prevention with proper mitigation actions
- Single cell failure detection without electrical or mechanical contact of cells
- Extended product lifetime
- Calibration-free product (only requires bump test)
- Highly reliable output signal
- Compatible with all lithium-ion battery form factors and chemistries
- Configurable communication protocols including Relay outputs and Modbus/ CANbus selection communication
- UL 2075 Recognized for Hydrogen (H2) detection
- UL 2075 Recognized for Carbon Monoxide (CO) detection*
- UL 2075 Recognized for Battery Electrolyte Solvent Vapour detection
Includes Diethyl Carbonate (DEC), Dimethyl Carbonate (DMC), and Ethyl Methyl Carbonate (EMC)
- ULC S588 Recognized for Hydrogen (H2) detection**
- FM 6540 Approved for Battery Electrolyte Solvent Vapours (ex. DEC, DMC, EMC)**
- ETL listed to UL 61010 and CSA 22.2 NO. 61010 for product safety
- EN 61326 for EU Directive (2014/30/EU)
- RoHS 3 (EU 2015/863)
- CE
- UKCA
- FCC
- CSFM (according to UL 2075 for H2)* Model (LT-SEN-M-C49) only.** Model (LT-SEN-M) only.
Certification of Interface Module:
- Certification of fire alarm system module UL864 10th
- ULC S527
- FM 6540
- Safety UL61010-1
- RoHS EN50581-2002
- EMI EN55011-2010
- EMC EN61326-1-2021
Certification of Off-Gas Sensor:
Official manufacturer product information
Additional manufacturer specifications
- Technical Data: Minimum Sensitivity: 10 ppm/sec; Operating Humidity: Off-Gas Sensor: 5% to 90% RH (non-condensing) Interface Module: 5 % to 95%RH (non-condensing); Operating Temperature: Off-Gas Sensor: -40 °C to 50 °C Interface Module: -40 °C to 70 °C
Technical Specifications
| Brand | Li-ion Tamer |
|---|---|
| Certification of Interface Module | Certification of fire alarm system module UL864 10th ULC S527 FM 6540 Safety UL61010-1 RoHS EN50581-2002 EMI EN55011-2010 EMC EN61326-1-2021 |
| Features | Lifetime: >10 years; Minimum Detection Threshold: 10 ppm/sec; Minimum Response Time: 5 seconds |
| Gases Detected | Lithium-ion battery electrolyte solvent vapors and hydrogen gas |
| Maximum Operating Humidity | 90 % RH (non-condensing) % RH |
| Minimum Operating Ambient Temperature | -10 to 50 °C |
| Minimum Operating Humidity | 20 % RH (non-condensing) % RH |
| Sensor Element | Gases Detected: LT-SEN-M: Hydrogen gas (H2) and Battery electrolyte solvent vapours; Gases Detected: LT-SEN-M-C49: Hydrogen gas (H2), Battery electrolyte solvent vapours and Carbon monoxide (CO) |