FNP-1127-SLC - Single Loop Expander Card for FireNET® Plus
Hochiki·SKU: 0100-05920
The model FNP-1127-SLC Single SLC Loop Expander is a one loop expander board for the FireNET Plus FNP-1127E series control panel. The FNP-1127-SLC increases the loop capacity of the panel from 1 loop to 2 loops, doubling the loop capacity from 254 analog addressable points to 508. The loop expander
Request a quoteDescription
The model FNP-1127-SLC Single SLC Loop Expander is a one loop expander board for the FireNET Plus FNP-1127E series control panel. The FNP-1127-SLC increases the loop capacity of the panel from 1 loop to 2 loops, doubling the loop capacity from 254 analog addressable points to 508. The loop expander board installs quickly, mounting to the back of the main control board. The FNP-1127-SLC has the same functionality as the built-in SLC loop on the FireNET Plus panel and utilizes Hochiki's robust DCP loop protocol for highly reliable and fast alarm reporting. Shielded or twisted pair wiring for the SLC loop is not required.
STANDARD FEATURES
• Adds one SLC loop to the FireNET Plus (FNP-1127E series) control panel
• The SLC loop is capable of 127 sensors/modules, plus 127 analog sounder bases,
for a potential total of 254 addresses
• The FireNET Plus 1127E control panel supports one FNP-1127-SLC, for a total of
two SLC loops per panel
• Supports Class A and B wiring methods per NFPA 72 Styles 4, 6, and 7
(Style 7 requires isolators)
• Fully supervised & power limited SLC loop
• Supports Hochiki’s DCP (Digital Communication Protocol)
• Same functionality as built-in loop of FireNET Plus control panel
• Uses standard wire; shielded/twisted pair is not required on SLC loops
STANDARD FEATURES
• Adds one SLC loop to the FireNET Plus (FNP-1127E series) control panel
• The SLC loop is capable of 127 sensors/modules, plus 127 analog sounder bases,
for a potential total of 254 addresses
• The FireNET Plus 1127E control panel supports one FNP-1127-SLC, for a total of
two SLC loops per panel
• Supports Class A and B wiring methods per NFPA 72 Styles 4, 6, and 7
(Style 7 requires isolators)
• Fully supervised & power limited SLC loop
• Supports Hochiki’s DCP (Digital Communication Protocol)
• Same functionality as built-in loop of FireNET Plus control panel
• Uses standard wire; shielded/twisted pair is not required on SLC loops
Technical Specifications
| Board Current | 75mA (+ loop current) |
|---|---|
| Devices per loop | 127 sensors/modules + 127 digital analog sounder bases, 254 total |
| Loop Current | 400mA max. |
| Loop Load impedance | 50 ohms, 1uF, 1mH max. |
| Manufacturer part number | 0100-05920 |
| Model | FNP-1127-SLC |
| Operating Voltage | 24 - 40VDC |
| Size | 5.34" L x 4.52" W |
| System Capacity | 1 FNP-1127-SLC per FireNET Plus panel (FNP-1127E series only) |