S4 Single Output Interface PCB
The S4 Single Output Interfaces are suitable for mains switching, they provide normally closed and normally open contacts rated at 13A 250Vac (nominal 230Vac) resistive load.
Request a quoteDescription
The S4 Single Output Interfaces are designed for use control panel. Each module includes loop isolators for device isolation. The S4 Single Output Interfaces are suitable for mains switching, they provide normally closed and normally open contacts rated at 13A 250Vac (nominal 230Vac) resistive load. Each S4 interface use one of 207 available device addresses on a loop and respond to regular polls from the control panel reporting the type of device.
The S4 Single Output Interface is available in a metal box (S4-34415). The box provides cable termination points on the enclosure.
Features & Benefits:- Analogue addressable communications
- Built-in type identification automatically identifies
- Reliable communication technique with high noise immunity
- Soft or SAFE addressing
- Common mounting options including surface mount and DIN rail mount
- LPCB Approved EN54-17:2005 & EN54-18:2005
- LVD BS EN 60950-2002
Technical Specifications
| LPCB Approved EN54-17 | 2005 & EN54-18:2005 |
|---|
Documents & Technical Downloads
Loop Powered Interfaces Datasheet
Data Sheet · en
Vigilon Advanced Fire Detection and Alarm System Operations & Maintenance Manual
Operation And Maintenance Manual · en
Interface Module for Vigilon Low Voltage (MV) Output Installation Manual
Installation Manual · en
Interface Module for Vigilon Medium Voltage (MV) Output Installation Manual
Installation Manual · en
Vigilon Advanced Fire Detection and Alarm System Installation Manual
Installation Manual · en
Gent Nano Consultant's Specification Guide
Reference Guide · en
Generic Commissioning Instructions for Vigilon Plus Panel, Vigilon Compact Plus Panel and Vigilon Plus Nodes Based Fire Detection and Alarm System User Manual
User Manual · en
Generic Commissioning Instructions for Vigilon Plus Panel, Vigilon Compact Plus Panel and Vigilon Plus Nodes Based Fire Detection and Alarm System User Manual
User Manual · en
Vigilon Plus Consultant's Specification Guide
Reference Guide · en
S4-34415 Product Carbon Footprint Report
Sustainability Document · en
Vigilon Panel - Sound and Resound Alarms Options Reference Guide
Reference Guide · en
Vigilon Analogue Addressable Fire Detection and Alarm System User Manual
User Manual · en
S4-344XX Declaration of Performance
Declaration Of Performance · en
Related Products
View Cataloguearrow_forward
Edwards SIGA-IOI FG, Module, Input/Output;SIGA-IOI
Indicative Price
from
Edwards 4-AUDTELS-E Audio and Telephone Interface/Riser Module, Europe, Edwards
Indicative Price