FCPS-24 Remote Power Supply/Battery Charger
Fire Alarm Power Supply Units

FCPS-24 Remote Power Supply/Battery Charger

Gamewell·SKU: GWF-F-363201

Remote power supplies/battery chargers FCPS-24 are compact, cost-effective, 6- or 8-amp remote power supplies with battery chargers.

Request a quote

Description

Remote power supplies/battery chargers FCPS-24 are compact, cost-effective, 6- or 8-amp remote power supplies with battery chargers. They may be connected to any 12 or 24V fire alarm control panel (FACP) or may be used as standalone supplies. Primary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24V system accessories. They provide regulated and filtered 24V DC power to four NACs with various configuration options of Class B (Style Y) or Class A (Style Z). Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering 4-wire smoke detectors). They also contain a battery charger capable of charging 7 or 18 AH batteries, depending on the model.

 Features & Benefits: 

  • Operates as a “sync-follower” or as a “sync-generator” (default)
  • Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped permanently “ON” (standalone mode) 
  • In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable
  • Power-limiting technology meets UL power-limiting requirements
  • Form C normally closed trouble relay 
  • Fully supervised power supply, battery, and NACs
  • Selectable earth fault detection
  • AC trouble report selectable for immediate or hours-long delay 

Certifications:

  • FCPS-24F:
    • UL: S2424, S1287
    • ULC: CS868
    • MEA: 387-94-E
    • CSFM: 7315-0075:176
    • FM: 0Y3A0.AY
  • FCPS-24FS6(C/E):
    • UL Listed: S2424, S1287
    • ULC Listed: S2424
    • CSFM Approved: 7315-0075:0206
    • MEA: 387-94E
    • FM Approved
  • FCPS-24FS8(C/E):
    • UL Listed: S2424
    • ULC Listed: S2424
    • CSFM Approved: 7315-0075:0206
    • MEA: 219-02E
    • FM Approved
  • FCPS-24S6(C/E), FCPS-24S8(C/E):
    • UL Listed: S635, S674
    • ULC Listed: S635 (FCPS-24S6C & FCPS-24S8C)
    • CSFM Approved: 7315-0028:0225
    • MEA: 299-02-E
    • FM Approved

Official manufacturer product information

Technical Specifications

CSFM7315-0075:176
CSFM Approved7315-0028:0225
FCPS-24FUL: S2424, S1287 ULC: CS868 MEA: 387-94-E CSFM: 7315-0075:176 FM: 0Y3A0.AY
FCPS-24FS6(C/E)UL Listed: S2424, S1287 ULC Listed: S2424 CSFM Approved: 7315-0075:0206 MEA: 387-94E FM Approved
FCPS-24FS8(C/E)UL Listed: S2424 ULC Listed: S2424 CSFM Approved: 7315-0075:0206 MEA: 219-02E FM Approved
FCPS-24S6(C/E), FCPS-24S8(C/E)UL Listed: S635, S674 ULC Listed: S635 (FCPS-24S6C & FCPS-24S8C) CSFM Approved: 7315-0028:0225 MEA: 299-02-E FM Approved
MEA299-02-E
UL ListedS635, S674
ULCCS868
ULC ListedS635 (FCPS-24S6C & FCPS-24S8C)

Documents & Technical Downloads

Firefighter’s Telephone ECC-FFT Instruction Manual

User Manual · en

FCPS-24FS8 8-Amp, 24-Volt Power Supply Data Sheet

Data Sheet · en

FCPS-24FS6 24 Volt, 6 Amp Power Supply Data Sheet - Fire-Lite

Data Sheet · en

Power Supplies with Battery Chargers

Data Sheet · en

NOTIFIER Seismic Certificate of Compliance

Certificate Of Conformance · en

Certificate of Compliance

Certificate Of Conformance · en

PS Series Remote Conventional Power Supply Expanders Product Bulletin

Product Bulletin · en

Notifier Overview Slide Presentation

Slide Presentation · en

FCPS-24FS6-8 Drawing

Drawing Or Diagram · en

FCPS-24S6(c-E) & FCPS-24S8(C-E) Data Sheet

Data Sheet · en

FCPS-24FS8C BIM File

Bim Object · en

FCPS-24S8 Drawing

Drawing Or Diagram · en

NFS2-3030-NCA-2 and FCPS-24S6-8 Installation Manual

Installation Manual · en

50-POINT INTELLIGENT COMMUNICATING FIRE DETECTION SYSTEM Engineering Specifications

Engineering Specifications · en

NOTIFIER Fire Alarm Control Panels Certificate of Approval

Certificate Of Approval · en

FCPS-24S6 - FCPS-24S8 Series Remote Power Supplies Data Sheet

Data Sheet · en

FCPS-24 and FCPS-24C Discontinued Technical Bulletin

Technical Bulletin · en

Field Charger-Power Supply FCPS-24S6 - FCPS-24S8 FCPS-24S6E - FCPS-24S8E FCPS-24S6C - FCPS-24S8C Installation Manual

Installation Manual · en

FCPS-24F Field Charger Power Supply (Excel)

User Manual · en

FCPS-24FS6 and FS8 Field Charge Power Supplies (Excel)

User Manual · en

FCPS-24FS6 and FCPS-24FS8 power supply-battery chargers Listing

Listing · en

FCPS-24FS6 & FCPS-24FS8 Circuit Board Replacement Installation Document

Installation Manual · en

FCPS-24FS6 and FS8 Field Charger Power Supplies

User Manual · en

FCPS-24F-FCPS-24FE Field Charger-Power Supply Installation, Operation and Application Manual

User Manual · en

FCPS-24F Field Charger Power Supply

User Manual · en

FCPS Field Charger-Power Supply

User Manual · en

FCPS-24FS6-8 Field Software Change Procedure

User Manual · en

Power-supply Units Fire Listing

Listing · en

FCPS-24S6(c-E) & FCPS-24S8(C-E) - Data Sheet

Data Sheet · en

MS-9200(C-E) -9200(C-E) Addressable Fire Alarm Control Panel Data Sheet

Data Sheet · en