Gamewell-FCI Elevate™ Transmitter Module
Gamewell·SKU: GWF-F-4059035
The TM-8 is a transmitter module that communicates on the AIO Bus (Annunciator Input/Output) for fire alarm control panels on the Gamewell-FCI Elevate™ Platform.
Request a quoteDescription
The TM-8 Transmitter Module provides the GFP-A/GFP-AR fire alarm control panels on the Gamewell-FCI ElevateTM Platform with eight programmable Form-C relays, along with either remote station service featuring three reverse-polarity outputs (Alarm, Trouble, and Supervisory) or a single municipal fire alarm box trip output on one PC board.
Features & Benefits:
The TM-8 is designed to meet NFPA 72 requirements for Auxiliary Protective Signaling Systems and Remote Station Protective Signaling Systems.
Features & Benefits:
- Customizable 80-character Primary label per module.
- On each TM-8 module, either the three reverse-polarity outputs (alarm, trouble, and supervisory) or the fire municipal box trip can be used.
- Connects to the internal AIO bus and mounts inside the GFP-A/GFP-AR cabinet on the PMB’s right-side option card position.
- The power run to the module does not need to contain a power supervision relay since loss of power or communication is inherently supervised through AIO communication bus.
- Diagnostic LEDs: green for Power, AIO bus Data Reception and AIO Data Transmission status; yellow for Trouble.
- Out of the three reverse polarity outputs, Remote Station Supervisory circuit can be reprogrammed for other functions using the panel programming tool.
- Remote Station Alarm circuit provides the option to combine trouble indication on the Alarm contact.
- Programmable participation in Trouble Delay for AC fail condition when using Remote Station Service.
- Programmable participation in Alarm Delay for PAS for the Remote Station Service and Master box Trip.
- Programmable option to cancel Alarm indication when signals are silenced for remote station and municipal box trip.
- Total of 8 programmable Form-C Relays:
- Four low-current
- Four higher current relays - The higher current relays can also be used to switch inductive loads (0.35PF).
- The Relay 1 is predispositioned to be a fail safe trouble indication but can be reprogrammed.
- Each of the 8 relays can be mapped to activate with a local or network:
- Event condition (i.e. fire, CO, supervisory, etc.)
- Activation of a point (i.e. detector, module)
- Activation of a zone (general zone, logic zone, releasing zone states, special function zone) - Isolated 24 V for the Remote Station reverse-polarity outputs.
- Remote Station Disconnect mechanism can be initiated from the panel display. It provides a means for inhibiting alarm status changes, which cause trouble indication for unit at the FACP. Operation of the disconnect mechanism will also create a trouble condition on the reverse-polarity output circuits or the master box trip
The TM-8 is designed to meet NFPA 72 requirements for Auxiliary Protective Signaling Systems and Remote Station Protective Signaling Systems.
Technical Specifications
| Alarm current | 189 mA at 24 VDC, all relays energized |
|---|---|
| Diagnostic LEDs | green for Power, AIO bus Data Reception and AIO Data Transmission status; yellow for Trouble. |
| Dimensions (W x H) | Approximately 4.375 x 7 inches |
| Manufacturer model | TM-8 |
| Operating temperature | 0-49 degrees C |
| Operating voltage | Filtered, non-resettable 24 VDC |
| Programmable relays | 8 Form-C relays; four low-current and four high-current |
| Remote station outputs | Three isolated reverse-polarity outputs; 15 mA maximum per output |
| Standby current | 81 mA at 24 VDC |
| Total of 8 programmable Form-C Relays | - Four low-current - Four higher current relays |