FS20X Flame Detector
Flame Detectors

FS20X Flame Detector

Notifier·SKU: FS20XFlameDetector

FS20X is an advanced UV/IR/VIS flame detector offering rapid response, wide-area coverage, and dependable detection of hydrocarbon and non-hydrocarbon fires in challenging conditions.

Request a quote

Description

Product Overview:
Based on the foundation of the highly successful and reliable SS4 Flame Detector, the FS20X Flame Detector represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The FS20X is a Multi-Spectrum and UV/Dual IR/VIS Flame Detector with a proven UV solar-blind sensor. The FS20X exhibits faster false-alarm free response to fires over a wider temperature range and with a much longer detection range compared to conventional UV/IR detectors.
Conventional and older technology UV/IR detectors, using narrow band 4.3 micron IR sensors, will not respond to smoky fires or if the detector lens is contaminated with oil and other substances since both UV and 4.3 micron signals are attenuated, obscured or absorbed by thick smoke or detector lens contaminants. Also, these old technology UV/IR detectors will not alarm to any fire if they are installed behind ordinary window glass.
Dual microprocessors provide a high level of fail-safe operation combined with fast and reliable performance. The Master Microprocessor performs high-speed digital sampling and signal processing calculations: while the slave microprocessor handles various sensor data, performs communications, self-diagnostics and provides interface versatility: and additional memory for storing Event Log and FirePic™ data.
The FS20X Flame Detector has a detection range in excess of 200 feet (very high sensitivity setting) for the detection of a one square-foot Heptane reference fire and has a cone of vision greater in volumetric coverage than most UV/IR detectors. This means fewer detectors can be used as compared to other manufacturers’ detectors.
Additional Features and Benefits:
  • Patented* WideBand IR™ Infrared combined with Ultraviolet
  • Detection range greater than 200 feet to 1 sq. ft. heptane fire
  • Patented* Electronic Frequency Analysis
  • Visible Sensor for optimum false alarm rejection
  • Selectable detection sensitivities
  • Solar blind 90° full 100% cone-of-vision
  • Dual Microprocessors for reliable performance
  • Real-time clock for accurate time dating of events
  • FirePic™ — Up to 6 pre-fire event data storage
  • Event log — Up to 200 events with date and time stamp
  • Built-in RS-485 ModBus Communication
  • Built-in non-isolated 4-20 mA analog output (sink or source)
  • Alarm, Fault and Fire Verification relays.
  • Automatic Optical Path and Electronic Self-Test
  • Widest operating temperature range
  • Patented* Electronics Module for components protection with plug-in terminations for easy field installation
  • Two ¾” NPT OR 25mm conduit entries
  • Low power consumption
  • High RFI and EMI immunity
  • FM approved
Benefits:
  • Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
  • Arc welding immunity
  • False alarm rejection for all environmental conditions
  • Minimal maintenance for trouble-free operation
  • PC software and Interface Module (FSIM) for fault diagnostics real-time graphs (RTGs), and downloading of FirePics™ and event log
  • Suitable for a wide variety of applications.
Features & Benefits:
  • Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
  • Range greater than 200 feet to 1 sq. ft. heptane fire
  • Arc welding immunity
Quick Specs:
  • Field of view: 90° full 100% core of vision, ± 45° from on axis
  • Operating voltage: 24 VDC nominal (18-32 VDC) - regulated
  • Sensitivity: Very high, high, medium and low - switch selectable
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Official manufacturer product information

Additional manufacturer specifications

  • Warnings & Restrictions: Do Not Use Silicone-Based or Commercial Window Cleaning Products; These will Degrade the Model FS20X Detector Performance; Warning: Potential Electrostatic Charge and Wipe Enclosure Only with a Damp Cloth
  • Application: Acetylene Processing and Storage; Aircraft Hangars; Chemical Production, Storage and Loading Facilities; Crude Oil and Gasoline Storage and Tank Farms; Ethanol, Methanol and IPA Production and Storage; Hydrogen Plants and Storage; LNG/LPG Loading and Unloading Facilities; Natural Gas and CNG Plants; Off-Shore Platforms; Oil and Gas Pipelines and Pumping Stations; Paint and Solvent Storage; Refineries and Oil Production Facilities; Turbine/Compressor Enclosures

Technical Specifications

Alarm IncludedYes
Altitude Range200ft (60m)
Analog Output Signal TypemA
BrandHoneywell; Honeywell; Notifier
Certifications - RegionalGlobal
CommunicationFireBus II; ModBus Protocol; RS485
Conduit Entries(2) 3/4 in NPT
Default Relay ActivationAlarm Relay (Relay 1), Auxiliary Relay V (Relay 2), Fault Relay (Relay 3)
Enclosure Material316 Stainless Steel; Copper-Free Powder Coated Aluminum; Copper-Free Powder Coated Aluminum or 316 Stainless Steel
FeaturesArc Welding Immunity
Field of view90° full 100% core of vision, ± 45° from on axis
Humidity Range5 to 98% RH (Non-Condensing)
IndustryAerospace; Energy; Government & Public Sector; Logistics & Warehouses
Ingress ProtectionIP66
Loop Resistance50 to 400 Ohms; 50 to 400 Ohms
Maximum Analog Input Resistance400
Maximum Operating Current83 mA
Minimum Temperature-40˚C
MountingSwivel Bracket Assembly
Mounting Hole Diameter0.25
NEMA RatingNEMA 4, 4X
Number of Digital Communication Ports2
Number of Relay Outputs3
Operating Current85
Operating voltage24 VDC nominal (18-32 VDC) - regulated
Output Signal Range4 to 20 mA
Output Signal TypemA
Plug Type10 pin for J2 Connector; 6 pin for J1 Connector
Relay Activation SettingsRelay 1: Fire Alarm; Relay 2: Fault; Relay 3: Auxiliary
Relay IncludedYes
Relay Output ConfigurationAuxiliary: SPDT (NO/NC); Fault: SPST (NO); Fire Alarm: SPDT (NO/NC)
Relay Rated Load1A @24V DC
Sensing MethodIR, UV
SensitivityVery high, high, medium and low - switch selectable
Spectral SensitivityNear Band IR: 0.7 to 1.1 microns; Ultraviolet: 185 to 260 Nanometers; Visible: 400 to 700 Nanometers; Wide Band IR: 1.1 to 3.5 Microns
Standards & CertificationsCE: EN6100-6-4 & EN50130-4
Storage Temperature-55 to +110°C; -55 to 100°C
Sub-CategoryFlame Detectors; Flame Detectors
VibrationMeets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
Visual IndicatorsGreen LED: Power; Red LED: Alarm; Yellow: Fault
Warranty3 Years from Date of Shipment
Wireless TechnologyWideBand IR™
WiringShielded: 2.5 sq.mm (14 AWG) to 0.326 sq.mm (22 AWG)