MRP-2001 Releasing Panel
MRP-2001 6-zone fire alarm control panels are for single- and dual- hazard deluge and pre-action applications.
Request a quoteDescription
MRP-2001 6-zone fire alarm control panels are for single- and dual-hazard deluge and pre-action applications. These panels provide reliable fire detection, signaling and protection for commercial, industrial, and institutional buildings requiring water-based releasing. These FACPs are compatible with System Sensor® i3 detectors, which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory freeze signal when the ambient temperature falls below the detector rating of approximately 45 °F (7.22 °C). The control panels are compatible with conventional input devices such as 2-wire smoke detectors, 4-wire smoke detectors, pull stations, water flow devices, tamper switches, and other normally open contact devices.
Features & Benefits:- Dual hazard operation
- Adjustable water flow discharge timer and two soak timers
- Cross-zone (double-interlock) capability
- Six programmable Style B (Class B) initiating device circuits (IDCs)
- Four programmable Style Y (Class B) output circuits
- Built-in NAC synchronization for System Sensor, Wheelock®, Gentex®, Faraday® and Amseco® devices
- 7A total 24V DC output current
- Resettable and non-resettable output power
- Built-in Programmer
- 80-character LCD display (backlit)
- UL: S624
- FM Approved
- CSFM: 7165-0075:0216
- MEA: 333-07-E
Technical Specifications
| Brand | Fire-Lite |
|---|---|
| Conventional / Addressable | Conventional |
| CSFM | 7165-0075:0216 |
| MEA | 333-07-E |
| Product Type | Conventional; Releasing |
Documents & Technical Downloads
MRP-2001(E) Deluge - Preaction Control Panel Data Sheet
Data Sheet · en
MRP-2001(C) Deluge - Preaction Control Panel Data Sheet
Data Sheet · en
Certificate of Compliance
Certificate Of Conformance · en
MRP-2001 Drawing
Drawing Or Diagram · en
MRP-2001 Deluge-Preaction Control Panel (dxf) Drawing
Drawing Or Diagram · en
MRP2001 Deluge-Preaction Control Panel (Microsoft Word format)
User Manual · en
MRP-2001 Battery Calculation (Excel)
User Manual · en
Control Units, Releasing Device Listing
Listing · en
MRP-2001 and MRP-2202 Deluge - Preaction Control Panel Listing
Listing · en
MRP-2001(E)(C) Pre-Action-Deluge Control Panel (Instruction Manual)
User Manual · en
Sell Supression Presentation
Document · en
Fire-Lite Device Compatibility Document
Device Compatibility Manual · en
SEISKIT-COMMENC PID
Installation Manual · en
MRP-2001(E)(C) Pre-Action-Deluge Control Panel (Operating Instructions)
User Manual · en
MRP-2001 Deluge-Preaction Control Panel
User Manual · en