Fike TwinflexPro2 Conventional Fire Alarm Control Panel
Conventional Fire Alarm Panels

Fike TwinflexPro2 Conventional Fire Alarm Control Panel

Fike·SKU: TWINFLEXPRO2

Two, four and eight zone conventional panel using the Twinflex protocol: up to 32 devices per zone on a single two-core screened cable, with a 500-event log.

Request a quote

Description

Two, four and eight zone conventional panel using the Twinflex protocol: up to 32 devices per zone on a single two-core screened cable, with a 500-event log.

TwinflexPro2

Because of its versatility, ease of installation and cost effectiveness, the TwinflexPro2 two-wire fire alarm is often the natural choice for smaller applications. The LPCB-approved fire alarm system incorporates Fike’s Twinflex Multipoint ASD, combining smoke and heat detection with an optional built-in sounder, allowing the entire system to be installed using just one pair of wires per zone.

Access Product Documents »

  • Differentiates between call point or smoke and heat alarms
  • 4 line x 20 character LCD display
  • Event log storing up to 500 events
  • Alarm confirmation verification feature for BS5839 Pt 6 applications
  • Available in 2, 4 and 8 zone panel versions
  • Up to 32 devices per zone
  • 3 enhanced test modes
  • No separate End Of Line (EOL) device required
  • Two-wire I/O module available for interfacing other types of detection

Twinflex Pro2

The TWINFLEXpro² two wire fire alarm system incorporating the Multipoint ASD combined smoke and heat detector with optional built-in sounder and strobe, allows the whole system to be easily installed using only one pair of wires per zone.

Using the Multipoint ASD detector as part of the TWINFLEXpro² two wire fire alarm system means that when a detector is wired to the system, a sounder and strobe can also be connected without extra installation time or cost. This greatly reduces the number of points that need to be installed and the time it takes to install. As the Multipoint ASD offers 7 different modes of detection, the installation is made even simpler since one device suits all applications. Whatever type of detection is required, it can be selected by the flick of a switch at the time of commissioning – 3 different smoke modes, 2 fixed temperature heat modes, a rate of rise mode and a combination smoke or heat mode.

The Multipoint ASD detector is available with or without a full specification integral 90 dBA sounder resulting in no extra devices need to be purchased when audible warning is required. If extra sound is required or for areas that do not require detection, then a choice of several different standalone sounders, call points or sounder beacons can be used on the same two wires.

This versatile system has the ability to differentiate between call point or detector alarm; can accommodate a maximum of 32 devices per zone; has separate fault monitoring display for each zone; and a man walk test facility and zones that can be configured without the need to use resistors or capacitors. To make the TWINFLEXpro² system even more flexible, Fike can also provide a special Input / Output Unit. This can be situated anywhere on the zone circuit, and is ideal for connecting to plant shutdown, door release mechanisms etc.

Repeater panels, which are small remote display units, can be connected to a 4 or 8 zone TWINFLEXpro² panel via an RS485 data link. A maximum of 8 Repeater Panels can be connected to a single control panel. Repeater Panels do not connect to or control any devices; they simply report all fire and fault events that occur in the system. They can also perform system actions over the data link (i.e. Silence Alarms, Reset, Sound Alarms and Silence Buzzer). Repeater Panels are intended to provide display capability at secondary building entrances, nurse’s stations and at any location where the panel event information is required to be displayed.

Checkpoint Alarm Confirmation Technology

With the increasing number of new builds, property conversions to flats and bed-sits, and greater pressure on environmental officers to actively enforce the requirements of BS5839 part 6 (the code of practice for fire detection and alarm systems in dwellings), landlords and building managers are continually looking for a reliable cost effective fire alarm solution. The ability to deliver reliable fire detection for these demanding applications, Fike has incorporated Checkpoint Technology into its TWINFLEXpro² control panels.

What is Checkpoint Technology?

At the planning stage of installation, fire zones are designated as ‘dwelling’ for individual rooms or apartments or ‘communal’ for common areas such as corridors or stairwells. The TWINFLEXpro² system has the ability to set a pre-alarm for dwellings, allowing time to investigate the cause of the activation before evacuating the building. This can be programmed between 1 to 5 minutes. When a fire is detected in a dwelling, only the local (room) sounder or sounders within that dwelling (dependent upon programming) will operate during the alarm verification period, to warn the occupants within that particular dwelling. The control panel will then carry out a number of checks over a specified period of time to confirm the detector is still in alarm and is a genuine fire. At the end of this checking period, if the detector ceases to signal alarm, the control panel will automatically reset the detector/sounder and the system will revert to its normal state. However, if the detector is still generating an alarm signal, the control panel will instantly sound all alarms in the building for full evacuation.

Detectors sensing fire (or call point activation in any zone) in communal areas instantly generate a full alarm throughout the building.

Official Fike product information

Technical Specifications

Battery2 x 12 V 3.3 Ah
BrandFike
Cable entry13 x 20 mm knockouts plus one 50 mm x 50 mm pull-out tab
Cable type2-core 1.5 mm2 screened fire-rated cable, 500 m maximum per zone
ConstructionV0 rated ABS
Device protocolTWINFLEX V3 + TWINFLEXpro
Devices per zoneUp to 32 Twinflex devices, subject to device loading units
Dimensions331 mm x 331 mm x 99 mm
Event log500 events
IP ratingIP30
Mains supply230 VAC +10%/-15%, 50/60 Hz
Operating standardBS EN54-2 and EN54-4
Operating temperature5°C to 40°C
Sounder and relay circuitsUp to 2 monitored sounder circuits and 2 monitored relay circuits; common fire and common fault relays on board
Weight (excluding batteries)2.25 kg (2 zone), 2.28 kg (4 zone), 2.36 kg (8 zone)
Zone labels12 characters
Zone variants2, 4 and 8 zone panels

Documents & Technical Downloads

Twinflex Brochure

Brochure · en

TWINFLEXpro² Data Sheet

Datasheet · en

TWINFLEXpro² Batt Calcs Spreadsheet

Software tool · en

TWINFLEXpro Eng&ComManual

Manual · en

TWINFLEXpro UserGuide

Manual · en

TWINFLEXpro² battery boxes

Datasheet · en

TWINFLEXpro² Conventional Expansion Card

Datasheet · en

TWINFLEXpro2 Expansion Card

Datasheet · en

TWINFLEXpro2 Repeater Manual

Manual · en

TWINFLEXpro Repeater UserGuide

Manual · en

Related system device: TF MP ASD Installation Instructions

Manual · en

Related system device: TF MCP Installation Instructions

Manual · en

Related system device: TF Flashpoint Installation Instructions

Manual · en

Related system device: TF Flashpoint Weatherproof Installation Instructions

Manual · en

Related system device: TF Hatari Installation Instructions

Manual · en

Related system device: TF HiPoint Installation Instructions

Manual · en

Related system device: TF Soundpoint Installation Instructions

Manual · en

Related system device: TF IO Installation Instructions

Manual · en

Related system device: Twinflex Sounder VAD F0296336

Datasheet · en

Related system device: Twinflex Sounder F0296337

Datasheet · en

TWINFLEXpro² CIE DoP 505-0002

Declaration of Performance · en

TWINFLEXpro² CIE DoP 505-0004

Declaration of Performance · en

TWINFLEXpro² CIE DoP 505-0008

Declaration of Performance · en

Related system device: Twinflex ASD NS DoP 204-0003

Declaration of Performance · en

Related system device: Twinflex ASD WS DoP 204-0001

Declaration of Performance · en

Related system device: Twinflex ASD WSS DoP 204-0012

Declaration of Performance · en

Related system device: Twinflex MCP DoP 402-0006

Declaration of Performance · en

Related system device: Twinflex MCP WP DoP 402-0007

Declaration of Performance · en

Related system device: Twinflex Flashpoint DoP 302-0012

Declaration of Performance · en

Related system device: Twinflex Flashpoint Domed DoP 302-0022

Declaration of Performance · en

Related system device: Twinflex Hatari DoP 302-000X

Declaration of Performance · en

Related system device: Twinflex Soundpoint DoP 313-002X

Declaration of Performance · en

Related system device: Twinflex Hipoint DoP 302-0004

Declaration of Performance · en

Related system device: Twinflex IO DoP 802-0006

Declaration of Performance · en

Simplex 4007-9202 (4007ES FACP, IDNAC)

Simplex 4007-9202 (4007ES FACP, IDNAC)

Indicative Price

from

Simplex 4004-9302 (Suppression Releasing Panel)

Simplex 4004-9302 (Suppression Releasing Panel)

Indicative Price

from

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)

Indicative Price

from

Simplex 4007-9102 (Fire Alarm Control Panel)

Simplex 4007-9102 (Fire Alarm Control Panel)

Indicative Price

from