Fike CIE-A-400 Addressable Fire Alarm Control Panel
One-to-two loop EN54 addressable control panel with 200 devices per loop, 32 fire zones, 32 I/O zones and support for up to eight repeater panels.
Request a quoteDescription
One-to-two loop EN54 addressable control panel with 200 devices per loop, 32 fire zones, 32 I/O zones and support for up to eight repeater panels.
CIE-A-400
The CIE-A-400 1-2 Loop Addressable Fire Alarm Control Panel is a single loop panel upgradable to two loops with an additional loop card (Sold separately 540-0003). Each loop is capable of supporting up to 200 devices* with a maximum loop length of 2KM. The panel also provides two configurable Monitored Input Circuits, 2 configurable Monitored Output Circuits, 2 configurable Relays, 1 Fault Relay and also a Peripheral Bus Circuit to add up to 8 Repeater Panels.
*Please check the CIE-A-400 device loading unit (DLU) calculation sheets for accurate loop loading calculations.
Access Product Documents
- One or Two Loop
- Loop length up to 2 km long
- Loop capacity up to 200 devices
- 32 fire zones and 32 I/O zones
- Alarm confirmation verification feature
- 1000 event history buffer
- Soft addressing
- 2 monitored inputs
- 2 monitored outputs
- 3 relays
- Up to 8 repeaters
- 7/9Ah max internal battery capacity or 12/17Ah with use of a battery box (540-0020)
Technical Specifications
| Approvals | EN54 Part 2 and Part 4 |
|---|---|
| Aux power output | 30 V DC, 350 mA |
| Brand | Fike |
| Display | Graphical LCD, 31-character device labels |
| Event log | 1,000 events |
| Inputs and outputs | 2 monitored inputs, 2 monitored outputs, 3 relays |
| Loop capacity | One or two loops, 200 devices per loop, 2 km maximum loop length |
| Loop operating voltage | 40 V DC |
| Mains supply | 230 VAC nominal |
| Max conductor resistance | 24 ohms |
| Max loop current | 500 mA |
| Operating temperature | 5°C to +40°C, IP30 |
| Panel dimensions (W x H x D) | 353 mm x 333 mm x 117 mm |
| Repeater panels | Up to 8 |
| Standby battery | 2 x 7/9 Ah 12 V sealed lead acid (2 x 12/17 Ah with extended battery box) |
| Zones | 32 fire zones and 32 I/O zones |
Documents & Technical Downloads
CIE-A-400 Data Sheet
Datasheet · en
CIE-A-400 Brochure
Brochure · en
FIKE-CIE-A-400 DoP 540-0001
Declaration of Performance · en
Related system device: Sita ASD NS DoP 205-0003
Declaration of Performance · en
Related system device: Sita ASD WS DoP 205-0001
Declaration of Performance · en
Related system device: Sita ASD WSS DoP 205-0012
Declaration of Performance · en
Related system device: Sita MCP DoP 403-0006
Declaration of Performance · en
Related system device: Sita MCP WP DoP 403-0007
Declaration of Performance · en
Related system device: Sita Sounder DoP 326-0001
Declaration of Performance · en
Related system device: Sita Sounder DoP 326-0003
Declaration of Performance · en
Related system device: Sita Sounder Strobe DoP 326-0021-R
Declaration of Performance · en
Related system device: Sita Sounder Strobe DoP 326-0023-R
Declaration of Performance · en
Related system device: Sita Soundpoint DoP 313-000X
Declaration of Performance · en
Related system device: Sita Hipoint DoP 323-0001
Declaration of Performance · en
Related system device: Sita IO DoP 803-0006
Declaration of Performance · en
Related system device: Sita CZM DoP 803-0010
Declaration of Performance · en
Related system device: Sita MO DoP 803-0022
Declaration of Performance · en
CIE-A-400 Engineering Manual
Manual · en
CIE-A-400 User Guide
Manual · en
CIE-A-200/A-400 Battery Box Installation Instructions
Manual · en
Related system device: RDU-A-400 Installation Guide
Manual · en
Related system device: Sita MP ASD Installation Instructions
Manual · en
Related system device: Sita Multipoint Boxed Auxiliary I/O Module
Datasheet · en
Related system device: Sita MCP Installation Instructions
Manual · en
Related system device: Sita MCPWP Installation Instructions
Manual · en
Related system device: Sita Sounder Deep Base Installation Instructions
Manual · en
Related system device: Sita Sounder Strobe Deep Base Installation Instructions
Manual · en
Related system device: Sita Strobe WP Installation Instructions
Manual · en
Related system device: Sita SoundPoint Installation Instructions
Manual · en
Related system device: Sita HiPoint Installation Instructions
Manual · en
Related system device: Sita I/O Module Installation Instructions
Manual · en
Related system device: Sita Conventional Zone Module Installation Instructions
Manual · en
Related system device: Sita Monitored Output Module Installation Instructions
Manual · en
CIE-A-400 Loop Card Manual
Manual · en
Related Products
View Cataloguearrow_forward
Simplex 4007-9201 (Fire Alarm Control Panel)
Indicative Price
from

Simplex 4010-9501 (4010Es Facp 240V)
Indicative Price
from

Simplex 4010-9502 (4010Es Facp 240V Red)
Indicative Price
from