IFP-2100 Fire Alarm Control Panel
Honeywell's Farenhyt series Analog Addressable Fire Alarm Control Panels are the controlling unit of a fire alarm system with an Emergency Communication System (ECS).
Request a quoteDescription
Honeywell Farenhyt Series is a new line of intelligent, flexible fire systems equipped with the latest technologies to protect your facilities. The basic IFP-2100 panel contains one built in signalling line circuit (SLC), which can support 159 System Sensor IDP/SK sensors and 159 IDP/SK modules or 127 Hochiki SD devices per loop. Additional SLC loops can be added using the model 6815 SLC expander for IDP/SK devices to increase the overall point capacity to 2100 or model 5815XL for SD devices to increase the overall point capacity to a maximum to 2032 points per panel. IFP-2100 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. The RFP-2100 (red) or RFP-2100B (black) can be used in a networked system where at least one IFP-2100 is in the system. It is the same as the IFP-2100 without the display.
IFP-2100 has eight on-board Flexput™ circuits that can be configured for auxiliary power, notification outputs, or for conventional smoke detector inputs (Class A or Class B). The FACP also has a Built in dual phone line digital alarm communicator/transmitter (DACT), IP or optional cellular technologies, Form C trouble relay, and two programmable Form C relays. IFP-2100 has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert.
Features & Benefits:- Network support for up to 32 Sites
- Built-in support for up to 159 IDP/SK detectors and 159 IDP/SK modules or 127 SD SLC devices
- Four programmable function keys
- Four line LCD display with 40 characters per line
- Available in a red or black cabinet
- NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72
- UL Listing; CSFM (pending)
- COA (pending)
- OSHPD (CA) (pending), FM (pending)
Technical Specifications
| Brand | Farenhyt; Silent Knight |
|---|
Documents & Technical Downloads
CLSS Gateway User Manual
User Manual · en
Male voiceWe have a fire alarm in our buliding. Please stay in your apartment and keep your apartment door closed. Keep your windows shut and leave all fire doors closed. Do not use the elevators and stand by for further information from the fire deparmen
Voice Message File · en
Female voiceAttention please. There has been a report of an emergency. Proceed calmly to the nearest exit and leave the building immediately. Do not use theelevators. Use stairwells where necessary. All handicapped occupants shall use the building evacuat
Voice Message File · en
Male VoiceThe building emergency has now ended. Please resume your normal duties. Thank you for your cooperation
Voice Message File · en
Female voiceAttention please, attention please, an emergency situation exists. Please proceed to the nearest shelter in place location
Voice Message File · en
Male VoiceThe emergency has now ended. Please resume normal operations. Thank you for your cooperation.
Voice Message File · en
Female voiceAttention please, the signal tone you have just heard indicates a report of an event in the building. You should await further instructions while the report is being verified. If further action is necessary, you will be instructed to follow fl
Voice Message File · en
Female VoiceAttention. Attention. Attention. An emergency has been resported. All occupants walk to the nearest exit and evacuate the building immediately. Do not use the elevator. Walk to the nearest stairway. Do not use the elevator. Walk to the nearest
Voice Message File · en
Female VoiceThe current emergency has now been cleared. Please report back to your work area. The current emergency has now been cleared. Please report back to your work area
Voice Message File · en
Male VoiceAttenion. Attention. The force protection condition has been changed. All personnel are to immediately implement prescribed actions. Tune your television to the commander's access channel or access the base internet for further information.
Voice Message File · en
Male VoiceAttention. Attention. The force protection condition has been elevated. All personnel are to immediately implement prescribed actions. Tune your television to the commander's access channel or access the base internet for further information.
Voice Message File · en
Male VoiceMay I have your attention please. May I have your attention please. A tornado watch has been issued for this area. A tornado watch has been issued for this area. Please be alert for further instruction. Please be alert for further instruction
Voice Message File · en
Female voiceThis an ameregency evaution of the building. Please proceed to your designated assigned area. Role will be taken immediately at the assembly areas.
Voice Message File · en
Male VoiceAttention, Attention, A Bomb threat alert has been issued for this building, all personnel are to evacuate immediately using the nearest exit. Further instructions will be issued outside the building by emergency response teams.
Voice Message File · en
Female VoiceMay I have your attention please. May I have your attention please. A tornado warning has been issued for this area. A tornado warning has been issued for this area. Please proceed to the designated tornado shelter area.
Voice Message File · en
Male VoiceAttention. A force protection antiterrorism threat has been issued for this area. Effective immediatley we are operating secure and lockdown procedures. All personnel should remain calm and stay where you are. Please wait for further instruction
Voice Message File · en
Fire Alarm and Emergency Communications Systems Product Brochure
Brochure · en
Emergency Communications Systems -ECS- Product Bulletin
Product Bulletin · en
IFP-2100 Data Sheet
Data Sheet · en
Farenhyt - 5815XL and 6815 Intermittent Interference Best Practices
Technical Bulletin · en
IFP-2100 / IFP-2100B / RFP-2100 / RFP-2100B datasheet
Data Sheet · en
Class B SBUS Wiring
Drawing Or Diagram · en
Control Panel Board Assembly SLC Wiring
Drawing Or Diagram · en
Class A SBUS Wiring
Drawing Or Diagram · en
Silent Knight Farenhyt overview for A&Es-Sell Sheet
Brochure · en
Control Panel Board Assembly SBUS Terminal
Drawing Or Diagram · en
M23.6 - Product Retirement: Legacy Farenhyt Panels & Boards Product Bulletin
Product Bulletin · en
ECS-Series Emergency Communication System User Manual
User Manual · en
IFP-2100ECS Wiring Diagram
Drawing Or Diagram · en
ECS-CE4 Installation Manual
Installation Manual · en
IFP-2100ECS Operation & Maintece Manual
Operation And Maintenance Manual · en
ECS-INT50W Internal 50 Watt Amplifier Data Sheet
Data Sheet · en
LAN-Connected Horizon User Manual
User Manual · en
IFP-2100 Operation & Maintece Manual
Operation And Maintenance Manual · en
ECS-LOC Local Operating Console Data Sheet
Data Sheet · en
ECS-NVCM Installation Manual
Installation Manual · en
RPS-1000 Intelligent Remote Power Supply User Manual
User Manual · en
ECS-LOC Installation Manual
Installation Manual · en
IFP-2100 ECS System Sensor Engineering Specifications
Engineering Specifications · en
SLC Wiring (Farenhyt)
Wiring Manual · en
ECS Emergency Communication System-Installation Manual
Installation Manual · en
ECS-125W Amplifier Data Sheet
Data Sheet · en
SK-FML-SK-FSL Fiber Option Installation Manual
Installation Manual · en
ECS-NVCM Install Sheet
Installation Manual · en
IFP-2100/ECS FACP Manual
Installation Manual · en
IFP-2100/ECS FACP Manual
Installation Manual · en
IFP-2100 Series Manual
Installation Manual · en
Device Compatibility Document
Device Compatibility Manual · en