411 Series Fire Alarm Communicators
Communication Gateways

411 Series Fire Alarm Communicators

Farenhyt·SKU: FAR-F-361379

Fire Alarm Communicators designed for a variety of fire and non-fire applications

Request a quote

Description

Fire Alarm Communicator designed for a variety of fire and non-fire applications. It provides four channels (three on the 411) that accepts waterflow devices, two-wire and four-wire smoke detectors, pull stations, and other normally-open contact devices. Three models are available: 411 - Slave Communicator; 411UD - Slave Communicator with upload/download; 411UDAC - Stand-alone Communicator with upload/download.

 Features & Benefits: 

  • Fully programmable with Pro-411 or with Windows Inputs may be individually programmed for stand-alone
  • Fully supervised trigger inputs require a contact closure for activation
  • Optional digital programming unit with a keypad, model PRO-411

Certifications:

  • Electrical Specifications:
    • Programmable Channels 1 through 4
    • Power-limited circuitry
    • Fully supervised
    • Operation: All channels NFPA Style B (Class B). Requires Normally Open contact to trigger
    • Normal operating voltage: 12 VDC
    • Alarm current: 3.34 mA
    • End-of-line resistor: 2.2K ohms
    • Short-circuit current: 3.8 mA per channel/input
  • Listings:
    • 411/411UD:
      • UL Listed: S2424
      • CSFM: 7300-0075:0174
      • MEA: 328-94-E Vol. III (411UD); 328-94-E Vol. IV (411)
      • FDNY: COA#6085
    • 411UD:
      • UL Listed: S624.
      • CSFM: 7300-0075:0174.
      • MEA: 328-94-E Volume

Official manufacturer product information

Technical Specifications

Alarm current3.34 mA
BrandFarenhyt; NOTIFIER
CSFM7300-0075:0174.
End-of-line resistor2.2K ohms
FDNYCOA#6085
Listings411/411UD: UL Listed: S2424 CSFM: 7300-0075:0174 MEA: 328-94-E Vol. III (411UD); 328-94-E Vol. IV (411) FDNY: COA#6085 411UD: UL Listed: S624. CSFM: 7300-0075:0174. MEA: 328-94-E Volume
MEA328-94-E Volume
Normal operating voltage12 VDC
OperationAll channels NFPA Style B (Class B). Requires Normally Open contact to trigger
Short-circuit current3.8 mA per channel/input
UL ListedS624.

Documents & Technical Downloads

411UDAC Rev 2 Fire Alarm Communicator Data Sheet

Data Sheet · en

411 Series Communicator Data Sheet - Notifier

Data Sheet · en

411 Series Communicator Data Sheet - Fire-Lite

Data Sheet · en

411 Series Data Sheet

Data Sheet · en

Digital Alarm Communicator-Transmitters User Manual

User Manual · en

Digital Alarm Communicator- Transmitter User Manual

User Manual · en

Fire Alarm Communicator 411UDAC User Manual

User Manual · en

411 Drawing

Drawing Or Diagram · en

411 Series Communicator Data Sheet - Gamewell-FCI

Data Sheet · en

IP Fire Alarm Communicator Installation Manual

Installation Manual · en

411UDAC Rev 2 Data Sheet-Data Sheet

Data Sheet · en

411UDAC DWG Drawing

Drawing Or Diagram · en

411 Series Slave Digital Alarm Communicator Transmitters Data Sheet

Data Sheet · en

Digital Alarm Communicator-Transmitter 411 Installation Manual

Installation Manual · en

411UDAC Circuit Board - Transformer Installation Manual

Installation Manual · en

411UDAC Digital Communicator Frame and Post

Frame And Post · en

411UDAC Dress Panel Installation Manual

Installation Manual · en

411UDAC Rev 2 Data Sheet

Data Sheet · en

411UDAC Circuit Board & Transformer Connection

User Manual · en

411UDAC Battery Calculation (Excel)

User Manual · en

411 UDAC Fire Alarm Communicator

User Manual · en

411UDAC Fire Alarm Communicator Data Sheet

Data Sheet · en

411 UDACT

User Manual · en

P K-411UD Windows-Based Off-Line Programming Utility Software Manual

User Manual · en

411UDAC Battery Calculation

User Manual · en

Digital Alarm Communicator-Transmitters 411-411UD Manual

User Manual · en

UDACTF, 411, 411-UD and 411UDAC digital alarm communicator transmitter Listing

Listing · en

411-411UD Digital Alarm Communicator Transmitter Data Sheet

Data Sheet · en