Designed for simple installation and operation, the 301C continuously monitors and controls toxic gases, combustible gases and oxygen hazards.
Product Overview:
Using an addressable RS-485 Modbus communication protocol, the 301C uses daisy chain wiring requiring only 2 pairs of wires to connect up to 96 transmitters on the 3 input channels. This simplifies installation, in turn lowering costs. The 301C’s zoning and averaging abilities significantly reduce operational and maintenance costs.
Zoning / Averaging:
The 301C controller offers unique zoning capabilities which permit the averaging and comparison of multiple sensor readings. Zoning can reduce operational costs by ensuring that localized brief fluctuations registered at a single transmitter do not activate relays. For example, a car idling in a parking structure may locally increase a reading at a nearby transmitter. Rather than activating a fan as a result of the temporary localized fluctuation, zoning can be used to limit relay activation until the average reading for a zone exceeds a set-point. This can reduce run time of fans, yielding savings in both energy usage and wear and tear. The 301C has the capacity to manage input from three Modbus channels for up to 96 transmitters and up to 50 wireless transmitters that can be associated with up to 126 zones. Transmitters can belong to an unlimited number of zones, providing maximum operational and control flexibility.
Additional Features and Benefits:
- Zero maintenance
- User Friendly
- Automatic quick self-test and warm-up
- Continuous alphanumeric display
Inexpensive and Reliable:
- Low installation costs
- Allows for up to 126 zoning groups which can save energy and extend fan and relay life
- Manages up to 768 events with programmable latching alarms
Flexible Operation:
- Optional BACnet/IP available
- Interchangeable transmitters able to detect different gases
- Expands to handle up to 96 transmitters or relay modules
- Programmable time delays
- Integrated time clock enables scheduling of system operations
Safety Measures:
- Full array of visual indicators and integrated 65dBA alarm levels
- Fully programmable relays (can be set as fail-safe or not)
Beneficial Options:
- Available in a heavy-duty industrial housing
- Datalogging option
Features & Benefits:
- User friendly with zero maintenance
- Low installation costs
- Automatic quick self-test and warm-up
Quick Specs:
- Power requirement: 17-27 VAC, 24-38 VDC, 500 mA
- Size: 11 (W) x 8 (H) x 2.8 (D) in. (28 x 20.3 x 7 cm)
- Weight: 2.4 lbs. (1.1 kg)
Official manufacturer product information
Additional manufacturer specifications
- Features & Benefits: Allows for up to 126 Zoning Groups which can Save Energy and Extend Fan and Relay Life; Automatic Quick Self-Test and Warm-up; Available in a Heavy Duty Industrial Housing (Model No. 96D); BACnet/IP Available; California Title 24 Network Option; Continuous Alphanumeric Display; Expands to Handle up to 96 Transmitters or Relay Modules; Full Array of Visual Indicators and Integrated 65dBA Alarm Levels; Interchangeable Transmitters able to Detect Different Gases; Manages up to 180 Events with Programmable Latching Alarms; Programmable Time Delays and Integrated Time Clock Enables Scheduling of System Operations; Zero Maintenance and Low Installation Costs
Technical Specifications
| Alarm Included | Yes |
|---|---|
| Alarm Settings | Fully Programmable Alarm Levels |
| Brand | Honeywell; Honeywell; Notifier |
| Communication Line Lengths | T-Tap: 65 ft. (20 m), Maximum per T-Tap: 130 ft. (40 m), Maximum for All T-Tap Combined; Up to 2,000 ft. (609 m) per Channel |
| Datalogging | Datalogging Option |
| Datalogging Capable | Yes |
| Decibels | 65 |
| Digital Communication Ports | Optional BACnet/IP Interface (BTL Listed as a Smart Sensor) |
| Display Included | Yes |
| Display Matrix | 122 x 32 Dot Matrix |
| Display Readout | Real-Time Gas Reading |
| Display Type | LCD |
| Graphic | Dot Matrix Backlit Display |
| Humidity Range | 0 to 95% RH (Non-Condensing) |
| Industry | Energy |
| Inlet Fan | Yes |
| Maximum Temperature | 50 |
| Minimum Temperature | -20 |
| NEMA Rating | NEMA 4x |
| Number of Relay Outputs | 3 |
| Operating Current | 500 |
| Operating Frequency Range | 50/60 Hz |
| Optional Memory | 2 GB Removable SD Card for Configuration, Readings and Events |
| Power requirement | 17-27 VAC, 24-38 VDC, 500 mA |
| Relay Included | Yes |
| Relay Output Configuration | 4 DPDT Relays (Alarms and/or Fault); 65 dBA Buzzer |
| Relay Rated Load | 5A, 30V DC or 250V AC (Resistive Load) |
| Relay Wire Size | 2 to 24 AWG |
| Security | Password Protection for Tamper Resistance |
| Series Name | 301C |
| Shielded | Yes |
| Size | 11 (W) x 8 (H) x 2.8 (D) in. (28 x 20.3 x 7 cm) |
| Standards | For Canada: CAN/CSA C22.2 No. 61010-1:04 (2nd Edition); For USA: ANSI/UL 61010-1 (2nd Edition) |
| Sub-Category | Gas Detection Controllers; Plastic Enclosure |
| Time Delay | 0 sec; 1 to 99 min Before and After Alarm; 30 sec; 45 sec |
| Visual Indicators | Alarm A: Red; Alarm B: Red; Alarm C: Red; Fault: Amber; Power On: Green; Rx: Green (Blinks when in Use); Tx: Amber (Blinks when in Use) |
| Weight | 2.4 lbs. (1.1 kg) |
| Weight range | 453.5 |
| Zoning | Up to 126 Programmable |
Related Products
View Cataloguearrow_forward
Bosch D382 Combustible Gas Detector, 12/24VAC/DC
Indicative Price
from