Edwards SIGA-PD — the Signature Series intelligent optical (photoelectric) smoke detector, now replaced by the Signature Optica SIGA-OSD.

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

Edwards SIGA-PD — the Signature Series intelligent optical (photoelectric) smoke detector, now replaced by the Signature Optica SIGA-OSD.

The SIGA-PD gathers analog information from its optical sensor and converts it into digital signals. Its on-board microprocessor measures and analyzes those sensor readings and compares them against historical data to make the alarm decision, with digital filters removing signal patterns that are not typical of fires. This is the single-sensor generation of the platform: where the SIGA-OSD that supersedes it uses dual optical wavelengths across multiple detection angles, the SIGA-PD works from one optical sensing chamber and historical comparison. It retains the Signature Series behaviors — electronic addressing, automatic device mapping, two levels of environmental compensation, two levels of dirty detector warning, twenty pre-alarm settings, five sensitivity settings and automatic day/night sensitivity adjustment.

The detector head ships on its own; the mounting base is a separate catalog number.

Specifications

Operating voltage 15.20 to 19.95 VDC
Normal operating current 51 µA
Alarm current 68 µA
Smoke sensitivity range UL/ULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
Air velocity 0 to 4,000 ft./min (0 to 20 m/s)
Vibration level 10 to 35 Hz, amplitude 0.01 in.
Wall mounting 12 in. (305 mm) max. from ceiling
Operating environment 32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing
Storage temperature -4 to 140°F (-20 to 60°C)
Environmental compensation Automatic
Construction High impact engineering polymer, white
Status LED Bicolor (green/red)
Compatible detector testers Testifire 1000, Testifire 2000
Agency listings CAN/ULC-S529, UL 268, UL 268A, CSFM, FM approved
Ship weight 0.4 lb (0.16 kg)

Installation notes

  • Superseded — check the listing edition before a like-for-like swap: this data sheet lists the SIGA-PD to UL 268 and UL 268A. The replacement SIGA-OSD is listed to UL 268 7th edition. Where a project or AHJ requires the 7th edition, the SIGA-PD does not satisfy it and the SIGA-OSD is the correct part.
  • FM is listed here but not on the replacement’s sheet: the SIGA-PD data sheet states “FM approved.” The SIGA-OSD data sheet’s agency listing row reads CAN/ULC-S529, UL 268-7, UL 268A and CSFM, with no FM entry. If an FM approval is a contract requirement, confirm the current status of the replacement part with Edwards rather than assuming it carries across.
  • Sensitivity range differs from the replacement: the SIGA-PD covers 0.53 to 3.94 %/ft; the SIGA-OSD covers 0.5 to 4.36 %/ft. A drawing that specifies a sensitivity setting at the edge of one range may not be reproducible on the other.
  • Base is a separate order: choose SIGA-SB / SIGA-SB4 (standard), SIGA-RB / SIGA-RB4 (relay), SIGA-IB / SIGA-IB4 (fault isolator), or SIGA-AB4G, SIGA-AB4GT, SIGA-AB4G-LF (audible). Bases are shared with the SIGA-OSD, so a base already installed can normally stay.
  • Trim skirt: the SIGA-TS4 is supplied with the 4-inch bases; SIGA-TS is the separate-order skirt for the non-4-inch bases.
  • Remote LED restriction: the SIGA-LED remote alarm LED is not for EN54 applications.
  • Panel compatibility: Signature Series device, up to 250 total Signature addresses per loop.

Related models

  • SIGA-OSD — the Signature Optica detector that replaces this model: dual optical wavelengths with multiple detection angles, nuisance rejection tuned against general cooking particulates, 0.5 to 4.36 %/ft, UL 268 7th edition, and lower draw at 32 µA standby / 45 µA alarm.
  • SIGA-OSCD — the Optica platform with an added carbon monoxide sensor, where CO detection is required alongside smoke.
  • SIGA-RTA — detector removal tool. SIGA-VA — detector cleaning tool.

Specifications taken from the Edwards data sheet “Intelligent Smoke Detector — SIGA-PD,” document E85001-0646, Issue 1.3. Manufacturer specifications are subject to change without notice.

Availability note: The supplier lists this product as discontinued/legacy. Availability is limited and should be confirmed before ordering.

Official supplier product page

Technical Specifications

Agency listingsCAN/ULC-S529, UL 268, UL 268A, CSFM, FM approved
Air velocity0 to 4,000 ft./min (0 to 20 m/s)
Alarm current68 µA
Compatible detector testersTestifire 1000, Testifire 2000
ConstructionHigh impact engineering polymer, white
Environmental compensationAutomatic
Normal operating current51 µA
Operating environment32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing
Operating voltage15.20 to 19.95 VDC
Ship weight0.4 lb (0.16 kg)
Smoke sensitivity rangeUL/ULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
Status LEDBicolor (green/red)
Storage temperature-4 to 140°F (-20 to 60°C)
Vibration level10 to 35 Hz, amplitude 0.01 in.
Wall mounting12 in. (305 mm) max. from ceiling
Context Plus Smoke detector built in sounder

Context Plus Smoke detector built in sounder

Indicative Price

from

Simplex 4098-9714 Photoelectric Smoke Detector

Simplex 4098-9714 Photoelectric Smoke Detector

Indicative Price

from

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Indicative Price

from