Edwards SIGA-OSD (Smoke Detector) 1.png
Smoke Detectors

Edwards SIGA-OSD (Smoke Detector)

Edwards·SKU: SIGA-OSD

Indicative Price

Excluding local taxes and shipping.

Smoke Detector

infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.

Description

The Signature Optica Series SIGA-OSD smoke detector brings advanced optical sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities.

Supplier product details

Edwards SIGA-OSD — a Signature Optica Series intelligent optical (photoelectric) smoke detector that reports analog sensor data digitally to a Signature loop controller.

The SIGA-OSD gathers analog information from multiple optical sensors and converts it to digital signals. Using dual optical wavelengths combined with multiple detection angles, it differentiates particles that are not representative of actual smoke; particle data feeds digital filters and a series of ratios that remove signal patterns typical of nuisance sources, reducing unwanted alarms. The on-board microprocessor measures and analyzes all optical sensor readings and compares them against preprogrammed settings to make the alarm decision. Continuous self-diagnostics and a permanently stored history log in non-volatile memory support maintenance, and automatic device mapping lets the loop controller supervise each device’s installed position so a detector cannot be returned to the wrong location after cleaning.

The detector head ships on its own. A mounting base is a separate catalog number and must be ordered to suit the application — standard, relay, fault-isolator, or audible/sounder.

Specifications

Operating voltage 15.20 to 19.95 VDC
Normal operating current 32 µA
Alarm current 45 µA
Smoke sensitivity range UL/ULC: 0.5 to 4.36 %/ft. (1.6 to 13.6 %/m) obscuration
Air velocity 0 to 4,000 ft./min (0 to 20 m/s)
Vibration level 10 to 35 Hz, amplitude 0.01 in.
Wall mounting 12 in. (305 mm) max. from ceiling
Operating environment 32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing
Storage temperature -4 to 140°F (-20 to 60°C)
Environmental compensation Automatic
Construction High impact engineering polymer, white
Status LED Bicolor (green/red)
Compatible detector testers Testifire 1000, Testifire 2000
Agency listings CAN/ULC-S529, UL 268-7, UL 268A, CSFM (7272-1657:0511)
Ship weight 0.4 lb (0.16 kg)

Installation notes

  • Base is a separate order: the data sheet lists every mounting base under Accessories, not with the detector. Choose SIGA-SB / SIGA-SB4 (standard), SIGA-RB / SIGA-RB4 (relay), SIGA-IB / SIGA-IB4 (fault isolator), or SIGA-AB4G, SIGA-AB4GT, SIGA-AB4G-LF (audible).
  • Trim skirt: the SIGA-TS4 trim skirt is supplied with the 4-inch bases. For the non-4-inch bases it is a separate order as SIGA-TS.
  • Remote LED restriction: the SIGA-LED remote alarm LED connects to the SIGA-SB or SIGA-SB4 standard base only. The isolator base does not support it. The data sheet also notes the SIGA-LED is not for EN54 applications.
  • Sounder base caution: SIGA-AB4G bases are not intended for use with combination carbon monoxide detectors in Fire-plus-CO mode. SIGA-AB4GT and SIGA-AB4G-LF support CO detectors when used with a SIGA-TCDR temporal pattern generator. The SIGA-AB4G mounts to a 4 inch square box only.
  • Panel compatibility: compatible only with control panels using a Signature loop controller. Up to 250 total Signature addresses per loop.
  • Boxes: mounts to North American 1-gang, 3-1/2 in. or 4 in. octagon, and 4 in. square boxes 1-1/2 in. (38 mm) deep; also European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4 and SIGA-IB4 are the versions that take a 4 in. square box.
  • Wiring: bases accept #18 AWG (0.75 mm²) through #12 AWG (2.5 mm²); #16 and #18 AWG are preferred. Maximum resistance per wire must not exceed 10 ohms.
  • Fault isolator behavior: on a shorted line all isolators open within 23 msec, then re-close at 10 msec intervals working outward from the loop controller; the isolator next to the short reopens within 10 msec. A detector must be installed in an isolator base for it to operate.
  • Sensitivity testing: the detector reports its own sensitivity measurement to the loop controller, and a report may be printed to satisfy the NFPA sensitivity measurement required at the end of the first year and every two years thereafter.

Related models

  • SIGA-OSD-NL — the same intelligent optical smoke detector supplied with no visible logo.
  • SIGA-OSCD — Signature Optica detector that adds a carbon monoxide sensor to the same optical smoke platform.
  • SIGA-PD — the earlier single-sensor Signature photoelectric detector that the SIGA-OSD supersedes; it uses one optical sensor rather than dual wavelengths and multiple angles.

Specifications taken from the Edwards data sheet “Intelligent Smoke Detector — SIGA-OSD,” document E85001-1001, Issue 1.5. Manufacturer specifications are subject to change without notice.

Supplier product page

Technical Specifications

Agency listingsCAN/ULC-S529, UL 268-7, UL 268A, CSFM (7272-1657:0511)
Air velocity0 to 4,000 ft./min (0 to 20 m/s)
Alarm current45 µA
Compatible detector testersTestifire 1000, Testifire 2000
ConstructionHigh impact engineering polymer, white
Environmental compensationAutomatic
Normal operating current32 µA
Operating environment32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing
Operating voltage15.20 to 19.95 VDC
Ship weight0.4 lb (0.16 kg)
Smoke sensitivity rangeUL/ULC: 0.5 to 4.36 %/ft. (1.6 to 13.6 %/m) obscuration
Status LEDBicolor (green/red)
Storage temperature-4 to 140°F (-20 to 60°C)
Vibration level10 to 35 Hz, amplitude 0.01 in.
Wall mounting12 in. (305 mm) max. from ceiling

Documents & Technical Downloads

Context Plus Smoke detector built in sounder

Context Plus Smoke detector built in sounder

Indicative Price

from

Simplex 4098-9714 Photoelectric Smoke Detector

Simplex 4098-9714 Photoelectric Smoke Detector

Indicative Price

from

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Indicative Price