Detector Bases
Edwards EC2-SB4 Standard Base
Edwards·SKU: EC2-SB4
Indicative Price
Excluding local taxes and shipping.
Edwards EC2-SB4 Standard Base with Trim Skirt, 4 Terminals, 6″ Diameter Key Features Self-diagnostic capability continually monitors operation Meets NFPA 72 sensitivity test requirements Head and terminal base design (base sold separately) Automatic drift compensation Tri-color status LED, solid...
infoNo online payment — request a quote and our team sends pricing. Prices are indicative and exclude taxes & shipping.
Description
Edwards EC2-SB4 Standard Base with Trim Skirt, 4 Terminals, 6″ Diameter
Key Features
- Self-diagnostic capability continually monitors operation
- Meets NFPA 72 sensitivity test requirements
- Head and terminal base design (base sold separately)
- Automatic drift compensation
- Tri-color status LED, solid red for alarm, flashing yellow for trouble and flashing green for standby
- Low-profile design blends into the ceiling
Specifications
| Contact us Phone: Email | edwards.fire@kgsolutions.com |
|---|---|
| Website | edwardsfiresafety.com |
| Electrical: Voltage | 6.5 — 33VDC |
| Electrical: Maximum ripple (peak to peak) | 10% (Vp - p) |
| Electrical: Typical standby current (24V) | 88μA |
| Electrical: Operating temperature | 32°F to 100°F (0°C to 38°C) for Heat & Photo/Heat |
| Electrical: Operating humidity range | 0 to 95% Non-condensing |
| Electrical: RFI immunity | 20 V/m min; 0-1000 MHz |
| Electrical: Remote LED output current | 5 mA min, 8.5 mA max |
| Electrical: Drift compensation adjustment | 1.0%/ft. max |
| Environmental: Heat Sensor Ratings | Fixed 135°F/ Rate of rise 15°F/min., >105°F (8.3°C/min., |
| Environmental: (EC2-H & EC2-OSH) | >40.6°C), FM response - Quick |
| Environmental: Maximum wind velocity | 0 to 4000 ft/min |
| Environmental: Field wiring size | 12-18 AWG |
Documents & Downloads
- Conventional 2-Wire Smoke and Heat Detectors (Data Sheet)
Technical Specifications
| Contact us Phone: Email | edwards.fire@kgsolutions.com |
|---|---|
| Electrical: Drift compensation adjustment | 1.0%/ft. max |
| Electrical: Maximum ripple (peak to peak) | 10% (Vp - p) |
| Electrical: Operating humidity range | 0 to 95% Non-condensing |
| Electrical: Operating temperature | 32°F to 100°F (0°C to 38°C) for Heat & Photo/Heat |
| Electrical: Remote LED output current | 5 mA min, 8.5 mA max |
| Electrical: RFI immunity | 20 V/m min; 0-1000 MHz |
| Electrical: Typical standby current (24V) | 88μA |
| Electrical: Voltage | 6.5 — 33VDC |
| Environmental: (EC2-H & EC2-OSH) | >40.6°C), FM response - Quick |
| Environmental: Field wiring size | 12-18 AWG |
| Environmental: Heat Sensor Ratings | Fixed 135°F/ Rate of rise 15°F/min., >105°F (8.3°C/min., |
| Environmental: Maximum wind velocity | 0 to 4000 ft/min |
| Website | edwardsfiresafety.com |
Documents & Technical Downloads
Related Products
View Cataloguearrow_forward
Simplex 4098-9792 (Standard Sensor Base, White)
Indicative Price
from

Simplex 4098-9793 (SSD Sensor Base)
Indicative Price
from

Simplex 4098-9789 (Sensor Base)
Indicative Price
from

Hochiki YBV-R/4(BLK)
Indicative Price
from