Edwards EC2-OS Smoke Detector Head Only, Photoelectric, Two-Wire (Base sold separately)

Edwards EC2-SB Standard Base, 4 Terminals

Key Features

  • Self-diagnostic capability continually monitors operation
  • Meets NFPA 72 sensitivity test requirements
  • Head and terminal base design (base sold separately)
  • Automatic drift compensation
  • Tri-color status LED, solid red for alarm, flashing yellow for trouble and flashing green for standby
  • Low-profile design blends into the ceiling

Specifications

Contact us Phone: Email edwards.fire@kgsolutions.com
Website edwardsfiresafety.com
Electrical: Voltage 6.5 — 33VDC
Electrical: Maximum ripple (peak to peak) 10% (Vp - p)
Electrical: Typical standby current (24V) 88μA
Electrical: Operating temperature 32°F to 100°F (0°C to 38°C) for Heat & Photo/Heat
Electrical: Operating humidity range 0 to 95% Non-condensing
Electrical: RFI immunity 20 V/m min; 0-1000 MHz
Electrical: Remote LED output current 5 mA min, 8.5 mA max
Electrical: Drift compensation adjustment 1.0%/ft. max
Environmental: Heat Sensor Ratings Fixed 135°F/ Rate of rise 15°F/min., >105°F (8.3°C/min.,
Environmental: (EC2-H & EC2-OSH) >40.6°C), FM response - Quick
Environmental: Maximum wind velocity 0 to 4000 ft/min
Environmental: Field wiring size 12-18 AWG

Documents & Downloads

Official supplier product page

Technical Specifications

Contact us Phone: Emailedwards.fire@kgsolutions.com
Electrical: Drift compensation adjustment1.0%/ft. max
Electrical: Maximum ripple (peak to peak)10% (Vp - p)
Electrical: Operating humidity range0 to 95% Non-condensing
Electrical: Operating temperature32°F to 100°F (0°C to 38°C) for Heat & Photo/Heat
Electrical: Remote LED output current5 mA min, 8.5 mA max
Electrical: RFI immunity20 V/m min; 0-1000 MHz
Electrical: Typical standby current (24V)88μA
Electrical: Voltage6.5 — 33VDC
Environmental: (EC2-H & EC2-OSH)>40.6°C), FM response - Quick
Environmental: Field wiring size12-18 AWG
Environmental: Heat Sensor RatingsFixed 135°F/ Rate of rise 15°F/min., >105°F (8.3°C/min.,
Environmental: Maximum wind velocity0 to 4000 ft/min
Websiteedwardsfiresafety.com

Documents & Technical Downloads

Context Plus Smoke detector built in sounder

Context Plus Smoke detector built in sounder

Indicative Price

from

Simplex 4098-9714 Photoelectric Smoke Detector

Simplex 4098-9714 Photoelectric Smoke Detector

Indicative Price

from

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Gentex S1209 Photoelectric Smoke Alarm, 120 VAC with 9V Battery Backup, 917-0059-002

Indicative Price

from