Eaton Modular rack-mounted addressable fire alarm control panel
Placeholder
Request a quoteDescription
Placeholder
Highlights
- Simple servicing: Comprehensive service and engineering functions
- Power: Integral battery and power supply
- Contacts: Up to 64 network "virtual contacts"
For medium to large sites with a central server, rack or control rooms
On medium to large sites, the installation of multiple fire alarm control panels can be a costly and protracted endeavour. What the R6000 offers is the opportunity to have numerous networked control panels in one room. Hidden away from the public, it removes the requirement to mount the networked control panels on multiple walls. Speeding up installation time by eliminating one task of many for integrators and keeping the building's architect happy by lessening the impact of the system on the structure's walls.
Modular design with the ability to combine multiple building management systems in one unit
Based on a standard rack configuration the R6000 can combine a number of different modules including fire detection, alarm signalling, public address/voice alarm and plant control in one unit. Bringing various building management service together in one easy to use and maintain rack unit.
No task too large with up to 65,512 addressable points
When we say the R6000 is designed for large sites we really mean it. Engineered to enable up to 126 x 19" rack modules the system can support 504 loops, the equivalent of 64,512 addressable points. Don't worry if you don't want to use the full system capacity, each rack can be customised to meet the demands of your project with 2 or 4 loop rack panels and blanking plates available to enable a tidy finish on the slam-latch lock door fronted unit.
Maintenance at the touch of a screen
Touch screens have come to dominate how we interact with many systems in everyday life and Eaton was at the forefront of bringing the technology to the fire market with the CF3000. 14 years later and we've continued to evolve its use enabling the R6000 interface to be versatile and easy to use for any end user.
PRODUCT CODES
- 2 Loop Rack Mount Fire Panel | R6000L2
- 4 Loop Rack Mount Fire Panel | R6000L4
- 2 Loop Rack Mount Networkable | R6000L2NC
- 4 Loop Rack Mount Networkable | R6000L4NC
- 19" Rack, 39 Units High | 39UECRACK
- 1 Unit Blanking Plate | 1UPLATE
- 2 Unit Blanking Plate | 2UPLATE
- 3 Unit Blanking Plate | 3UPLATE
- 6 Unit Blanking Plate | 6UPLATE
- Pack of 4 Fixing (1 required per blanking plate) | ECRACKPACK43
TECHNICAL SPECIFICATIONS
- | R6000L2 | R6000L4
- Standards: | EN54 Pt2,1997, A1:2006, EN54 Pt4,1997, A1:2002, A2:2006 | EN54 Pt2,1997, A1:2006, EN54 Pt4,1997, EN54 Pt4,1997, A1:2002, A2:2006
- Number of Loops: | 2 | 4
- Addresses per Loop: | 200* | 200*
- Number of Conventional Sounder Circuits: | 4 monitored for open and short circuit | 4 monitored for open and short circuit
- Auxiliary Fire Routing Equipment Output (Monitored): | 24V 30 mA (max) | 24V 30 mA (max)
- Auxiliary Fire Protection Equipment Output (Monitored): | 24V 30 mA (max) | 24V 30 mA (max)
- Auxiliary Fault Routing Equipment Output (Monitored): | 12V 30 mA (max) | 12V 30 mA (max)
- System Operating Voltage: | 24 Vdc (nom) | 24 Vdc (nom)
- Mains Input Supply: | 230V ac +10%/-15% | 230V ac +10%/-15%
- Class Change Facility: | Terminals for connection of external contacts, can also be instigated via input interface | Terminals for connection of external contacts, can also be instigated via input interface
- Auxiliary Relay: | 1 set of changeover contacts operate in event of fire condition | 1 set of changeover contacts operate in event of fire condition
- Output Ports: | RS485, RS232 for connection of repeaters etc | RS485, RS232 for connection of repeaters etc
- Standby Duration: | Dependent on loop loading and battery configuration | Dependent on loop loading and battery configuration
- Battery: | 2 x 12Ah (standard versions) 4 x 12Ah (EB versions) | 2 x 12Ah (standard versions) 4 x 12Ah (EB versions)
- Environmental | |
- Operating Temperature: | -5°C to +40°C | -5°C to +40°C
- Humidity (Non-condensing): | 0 to 93% (+2/-3%) RH | 0 to 93% (+2/-3%) RH
- Physical | |
- System Networking: | Fully networkable up to 126 panels (requires additional network card - 1 per panel) | Fully networkable up to 126 panels (requires additional network card - 1 per panel)
Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.
Technical Specifications
| Manufacturer highlight: Contacts | Up to 64 network "virtual contacts" |
|---|---|
| Manufacturer highlight: Power | Integral battery and power supply |
| Manufacturer highlight: Simple servicing | Comprehensive service and engineering functions |
Documents & Technical Downloads
Fire systems - Product Catalogue
Catalogues · en
Fire systems - Product catalogue (Cooper)
Catalogues · en
Fire systems - Product catalogue (JSB)
Catalogues · en
Fire systems - Product catalogue (Menvier)
Catalogues · en
R6000 addressable rack unit - Installation manual
Installation instructions
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Eaton Life Safety products - Reference book
Success stories · en
R6000 addressable rack unit - Datasheet
Technical data sheets
Addressable Fire Alarm Control Panels - Announcement of Retirement
Warranty guides · en
Fire system and devices - Extended warranty-policy and terms
Warranty guides
Upgrading to the xDetect fire control panel
White papers · en
Related Products
View Cataloguearrow_forward
Simplex 4007-9201 (Fire Alarm Control Panel)
Indicative Price
from

Simplex 4010-9501 (4010Es Facp 240V)
Indicative Price
from

Simplex 4010-9502 (4010Es Facp 240V Red)
Indicative Price
from