Eaton Conventional EN & UL reflective beam detector
Beam Smoke Detectors

Eaton Conventional EN & UL reflective beam detector

Eaton·SKU: EATON-F-B8FC7CE33C74

Eaton's advanced beam detector, EF-CBD50, is for use with the Eaton range of conventional fire systems. It prioritises ease of installation, whilst incorporating substantial performance improvements over previous models. This detector has been re-designed to remove the need for specialist tools or k

Request a quote

Description

Eaton's advanced beam detector, EF-CBD50, is for use with the Eaton range of conventional fire systems. It prioritises ease of installation, whilst incorporating substantial performance improvements over previous models. This detector has been re-designed to remove the need for specialist tools or knowledge for installation and operation. One person can install the product and initiate the auto-alignment procedure for hassle free commissioning. There are two versions of the detector, differentiated by either EN54 or UL certification. Each baseline model has a range of up to 50 metres. This can be extended to 120 metres with the additional long range kit.

Highlights

  • Intuitive: One person installation and commissioning
  • Efficient: Cost-effective smoke detection for large, open areas
  • Adaptive: Adapts to installation environment

Cost-effective smoke detection for large, open areas

The EN & UL certified beam detector replaces the need for large quantities of individual point detectors in large open areas such as commercial warehouses, airports, schools and arenas. A building with a large area may require up to 52 point detectors to ensure safe coverage, whereas two beam detectors could provide coverage of the same area. This helps deliver a more practical and cost-effective solution, whilst making system installation, commissioning and testing much simpler.

Efficiency in power and connectivity

The detector consumes just 5mA in all standard operational modes. It will align itself in under a minute if Fast Alignment is selected. In this mode, the current consumption will increase to 33mA and then revert back to 5mA once aligned. If Fast Alignment is off, the unit will draw 5mA of current, but will take up to 15 minutes to align itself. If these current requirements are factored into the system design, the product can be used on Eaton conventional zone without the need for an additional power supply unit. Fire and fault conditions are signalled to the panel using standard zone wiring, so no additional interconnections are required.

Technical specifications

  • Detection performance
  • Detection range | 0 to 50m 0 to 120m with Reflective Long Range K
  • Alignment method | Laser assisted, Auto-Alignment™. Manual alignment – optional setting
  • Auto-Alignment™ protocol | Background check, Box search, Adjust and Centre
  • Building Movement Tracking™ | Compensates for natural shifts in alignment from building movement*
  • Contamination Compensation | Compensates for gradual build-up of contamination on the optical surfaces
  • Light Cancellation Technology™ | Compensates for high levels of sunlight and artificial lighting
  • Optical wavelength – smoke detection | 850nm near infrared (invisible)
  • Integrated laser – laser alignment | 650nm visible. Class IIIa <5mW
  • Dynamic Beam Phasing | Allows beam detectors to be mounted facing each other with the reflectors in the middle. Eliminates false alarms caused by crosstalk between beams
  • Signal output | Individual Alarm and Fault relays (VFCO) 2A @ 30 VDC
  • Programmable user settings
  • Alarm response threshold levels | 25% (1.25dB) – Fastest response to smoke 35% (1.87dB) – Default value 55% (3.46dB) – High immunity to false alarms, slow response to smoke 85% (8.23dB) – Highest immunity to false alarms, slowest response to smoke Configured via the integrated user interface
  • Delay to Alarm | 10 seconds, for momentary partial obstruction of the beam path
  • Delay to Fault | 10 seconds, for momentary obstruction of the beam path
  • User features
  • Integrated user interface | Alignment mode switch, alignment directional buttons and configuration switches for alarm response threshold
  • Alignment status indication | 2 Green LEDs and 1 Yellow LED
  • System status indication | Normal operation – Green LED flashing every 10 seconds Alarm condition – Red LED flashing every 10 seconds Fault condition – Yellow LED flashing every 10 seconds for obscuration or every 5 seconds for contamination Flat front face with enclosed optics. Cleaning the optics does not affect alignment
  • Design parameters
  • Separation distance between Detector and Reflector | 5 to 50m 50 to 120m with Reflective Long Range Kit
  • Beam path clearance | 1m in diameter from centre line between Detector and Reflector
  • Detector dimensions | Width 130mm x Height 181mm x Depth 134mm (see diagram)
  • Reflector dimensions | Up to 50m separation distance – Single reflector 100mm x 100mm x 9mm Up to 120m separation distance – Four reflectors arranged in a square pattern 200mm x 200mm x 9mm
  • Product weight | Detector – 0.7kg; Reflector – 0.1kg
  • Multi-detector arrangement | Dynamic Beam Phasing allows for Detectors to face each other with the reflectors in the middle
  • Housing colour | White RAL9016, UV stable
  • Electrical specifications
  • Operating voltage | 14 to 36 VDC
  • Operating current (constant) all operational modes | All operational modes – 5mA; Fast alignment mode – 33mA
  • Field wiring
  • Cable gauge and type | 2 core, dedicated, 0.5 to 1.6mm (24 to 14 AWG) System compatible with fireproof and non-fireproof cable meeting local installation standards
  • Cable entry | 3 knock-out locations capable of accepting M20, ½” or ¾” glands 4 drill-out locations capable of accepting glands up to 21mm diameter
  • Test and maintenance
  • Alarm test | Optical alarm test using Commissioning and Maintenance Kit accessory
  • Environmental specifications
  • Operating temperature | -20 to +55°C
  • Storage temperature | -40 to +85°C
  • Relative humidity (non-condensing or icing) | 0 to 93%
  • IP rating | IP55
  • Housing flammability rating | UL94 V0 polycarbonate
  • NB: All figures are quoted for 25°C
  • Optical specifications
  • Fault level / Rapid obscuration (Δ ≤ 2 seconds) | ≥85%
  • Maximum angular alignment of Reflective Detector | ±4.5° (±70° with adjustment bracket accessory)
  • Maximum angular misalignment of Reflective Detector | ±0.5°
  • Maximum angular misalignment of Reflector | ±5°
  • *When mounted according to manufacturers guidelines

Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.