Eaton Conventional / BiWire Flexi fire alarm panel
The Conventional / BiWire Flexi fire alarm panel combines two technologies to provide a truly versatile fire safety solution. The panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be
Request a quoteDescription
The Conventional / BiWire Flexi fire alarm panel combines two technologies to provide a truly versatile fire safety solution. The panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. This provides you with the flexibility to utilise all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices, where required. It shares the same straightforward, intuitive interface as the 8 Zone conventional panel, providing a proven solution for simple programming and maintenance. The BiWire Flexi fire alarm system is certified to EN54 parts 2 and 4 and is designed to meet the recommendations of BS 5839.
Highlights
- Flexible: Easy to extend existing conventional systems
- Competitive: Two-wire system can reduce cabling by up to 50 %
- Fast: Typical system installation time can be reduced by a third
Installing a fire system extension as part of wider building work?
Two-wire (2-wire) fire alarm systems can often be overlooked when selecting additional devices or panels for building extensions; the cabling and devices are already in place and it can be perceived as expensive to replace them. The problem this creates is that any additional conventional devices added can be costly and require unnecessary additional cabling. BiWire Flexi provides the best of both worlds: new cost-effective 2-wire devices without replacing existing devices and a panel that works with both.
Simple to install, easy to find a fault
A handy fault-finding feature helps you locate problems relating to both open circuit wiring or removed detectors. The installation manual also shows how to put the panel into ‘self-test mode’ so that all detectors flash amber to indicate there is power to the devices and that they’re properly clipped in.
Product codes
- 2 Zone BiWire Flexi panel | EFBW2FLEXI |
- 4 Zone BiWire Flexi panel | EFBW4FLEXI |
- 8 Zone BiWire Flexi panel | EFBW8FLEXI |
Technical specifications
- Power Specification (2x MB512 batteries required. Batteries not included) |
- Input Voltage Range: | 18.75 - 30.7V |
- Maximum Current Drawn From Battery: | 2.7A |
- Zone Circuits |
- Number of Zones: | 2 / 4 / 8 |
- Devices Per Zone: | BiWire Mode: Max of 32 BiWire Detectors and Manual Call Points, total loading including BiWire sounders cannot exceed 200mA in alarm Conventional Mode: Max 32 Conventional Detectors and Manual Call Points Intrinsically Safe Conventional Mode: Max of 10 intrinsically Safe Detectors and Manual Call Point |
- Maximum Loading per Zone: | 200mA |
- Standby Zone Voltage: | Vmin 19Vdc Vmax 23Vdc |
- Alarm Zone Voltage: | Vmin 31Vdc Vmax 33Vdc |
- Fuse Protection Per Zone: | 250mA PTC |
- End of Line Termination: | BiWire Zones: EOLM-3 Only Standard Conventional Zones: EOLM-1 only Intrinsically Safe Zones: 6K8 resistor |
- Conventional Sounder Circuits |
- Number of Sounder Circuit: | BiWire Flexi 2 & 4 zone panels: 2 conventional sounder circuits BiWire Flexi 8 zone panel: no conventional sounder circuits if all zones are in BiWire mode BiWire Flexi 8 zone panel: 2 conventional sounder circuits if up to 4 zones are in conventional mode BiWire Flexi 8 zone panel: 4 conventional sounder circuits if 5 or more zones are in conventional mode |
- Maximum Loading Per Circuit: | 500mA |
- Fuse Protection Per Circuit: | 500mA PTC |
- End of Line Termination: | 6K8 Resistor |
- Unmonitored Outputs |
- Fire, Fault, Interlink Relay: | Type - Volt-Free, Single Pole Double Throw Rating - 30V DC, 1A Fuse - 500mA PTC |
- Auxiliary Output: | V - 18.15-30.7V Imax - 50mA Fuse - 50mA PTC |
- Unmonitored Inputs |
- Class Change: | Open Circuit - Normal Panel Operation Short Circuit - Activate All Sounders |
- Communications Ports |
- Repeater Port (use of this port is outside the scope of EN54): | Type - RS485 Nodes - 1 |
- Environmental |
- Operating Temperature: | -5°C to +40°C |
- Relative Humidity (Non-condensing): | 93% +/-3% |
- IP Rating: | IP30 |
- Mechanical |
- Weight (excluding batteries): | 2.25kg |
- Materials: | PC ABS Front and Rear |
- Cabling |
- Cable Access: | 29 x 20mm drill positions - Slots for rear cable entry |
- Cable Type: | Firetuf FT120 / FP200 Cable type 2 core 1.5mm, screened fire rated cable, 500m (Max per zone) |
- Compliance |
- Standards: | EN54 Part 2 CIE & Part 4 PSE, BS5839-pt1 |
Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.
Technical Specifications
| Manufacturer highlight: Competitive | Two-wire system can reduce cabling by up to 50 % |
|---|---|
| Manufacturer highlight: Fast | Typical system installation time can be reduced by a third |
| Manufacturer highlight: Flexible | Easy to extend existing conventional systems |
Documents & Technical Downloads
BiWire Flexi Systems - Brochure
Brochures · en
Eaton Fire Training Calendar 2026
Catalogues
Fire systems - Product Catalogue
Catalogues · en
Fire systems - Product catalogue (Cooper)
Catalogues · en
Fire systems - Product catalogue (JSB)
Catalogues · en
Fire systems - Product catalogue (Menvier)
Catalogues · en
BiWire Flexi control panel - Certificate of constancy of performance
Certification reports
BiWire Flexi control panel - Declaration of conformity
Certification reports · en
BiWire Flexi control panel - Declaration of performance
Certification reports · en
BiWire Flexi control panel - Installation manual
Installation instructions · en
BiWire Flexi Panel - User Manual
Manuals and user guides
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Eaton Life Safety products - Reference book
Success stories · en
Flexi control panel - technical datasheet
Technical data sheets · en
Fire system and devices - Extended warranty-policy and terms
Warranty guides
Related Products
View Cataloguearrow_forward
Simplex 4007-9202 (4007ES FACP, IDNAC)
Indicative Price
from

Simplex 4004-9302 (Suppression Releasing Panel)
Indicative Price
from

Simplex 4007-9101 (4007ES Hybrid with Four Conventional NACs Red)
Indicative Price
from

Simplex 4007-9102 (Fire Alarm Control Panel)
Indicative Price
from