Eaton Sounder VAD detector base for addressable fire systems
The compliant, fire approved sounder visual alarm device (VAD) detector base, is one of the most flexible and useful devices in Eaton's addressable range of fire devices. Including are all the features of the addressable sounder detector base, as well as a powerful LED beacon. Meeting the 4 lux outp
Request a quoteDescription
The compliant, fire approved sounder visual alarm device (VAD) detector base, is one of the most flexible and useful devices in Eaton's addressable range of fire devices. Including are all the features of the addressable sounder detector base, as well as a powerful LED beacon. Meeting the 4 lux output, the LED beacon is certified to be used as an open class VAD. There are two main options when specifying either adding a detector to create a sounder VAD detector or adding a cover plate to form a discrete sounder VAD. The device is compatible with Eaton's full range of addressable detectors and fire systems.
Highlights
- Flexible: Use either standalone with cover plate or with detector
- Customisable: Selectable tones and volume
- Certification: Approved to EN54-23 and CoP 0001
Adjustable volume settings - whats the benefit?
Three volume options are available: Low volume (83dB), Medium volume (90dB) or High volume (93db). Being able to choose to have the sounder at a low volume can be a power saving measure. If there is no need to have the sounder at a higher volume, more devices can be connected.
One connection point. Three devices. Multiple tones.
The range reduces installation points from three to one by providing a single connection for the detector, sounder and visual alarm device (VAD). Reducing the cost and space required for fire rated cable while also enabling a less cluttered finish. It is particularly applicable to concrete ceilings with limited space for cabling.
Easily customizable tones changed from the panel
A number of tones are available out of the box with Eaton's sounder VAD detector base including: Continuous, Pulsed, Two-tone and Slow whoop (which can have a 3.5 or 0.5-second gap between output).
PRODUCT CODES
- Open class VAD base | CASBB394
Additional technical details
- Total Loop Resistance for correct operation of short circuit isolator: 50Ω (max)
- Parallel Fault Resistance to be seen at the Control Panel for isolators to open: 200Ω (typ)
- Voltage at which isolator changes from open to closed or closed to open state: 3.8V to 11V
Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.
Technical Specifications
| Beacon | 0.5Hz Flash |
|---|---|
| Cable Size / Type | 0.5 - 2.5mm / FIRETUF, FP200 or MICC |
| Compliance | EN54-3 Fire Alarm Device – Sounder EN54-17:2005 EN54-23:2010 |
| Continuous Current allowable through isolator | 700mA (max) |
| Environment Category | Type A / IP21C |
| Isolator Resistance in closed state | 0.26Ω (max) |
| Leakage Current into direct short circuit with isolator open | 14mA (max) |
| Manufacturer highlight: Certification | Approved to EN54-23 and CoP 0001 |
| Manufacturer highlight: Customisable | Selectable tones and volume |
| Manufacturer highlight: Flexible | Use either standalone with cover plate or with detector |
| Material | ABS / PC FR Plastic |
| Maximum switching current of isolator | 1.5A |
| Operating Temperature | -10°C to +55°C (95%RH) |
| Sound Output @ =/-3d8 (set by panel) | Low volume: 83dB @ <8.6mA Medium volume: 90dB @ <10mA High volume: 93dB @ <11mA |
| Standby Current | < 450 uA |
| Supply Voltage | 19 – 30vdc |
| Tones (set by panel) | Continuous 910Hz Pulsed 910 / 0Hz pulse 1Hz Two Tone 610 / 910Hz @ 1Hz cycle Slow whoop 500-1200Hz in 3.5 seconds /0.5secs gap |
Documents & Technical Downloads
Fire systems - Product Catalogue
Catalogues · en
Fire systems - Product catalogue (Cooper)
Catalogues · en
Fire systems - Product catalogue (JSB)
Catalogues · en
Fire systems - Product catalogue (Menvier)
Catalogues · en
Addressable VAD detector base - Certificate of constancy of performance
Certification reports
Addressable VAD detector base - Certificate of constancy of performance
Certification reports
Addressable VAD detector base - Declaration of performance
Certification reports · en
Addressable VAD detector base - Declaration of performance
Certification reports · en
Fire installers mate - Fire systems and VADs design guide
Design guides
Visual alarm devices - Introduction to EN 54-23
Design guides
Addressable VAD detector base - Installation manual
Installation instructions · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Eaton Life Safety products - Reference book
Success stories · en
CASBB394(-VSR) - Technical data sheet
Technical data sheets
CASBB394(-VSR) - Technical data sheet
Technical data sheets
FXN557(-VSR) - Technical data sheet
Technical data sheets
MASB890(-VSR) - Technical data sheet
Technical data sheets
Fire system and devices - Extended warranty-policy and terms
Warranty guides
Related Products
View Cataloguearrow_forward
Standard addressable sounder base (without flasher/beacon); pure white.
Indicative Price
from

Hochiki ASBL7 Analog Sounder Base, Low Frequency
Indicative Price
from

Hochiki YBO-BS(WHT)/SIL Base Sounder White Case SIL2
Indicative Price
from