
Eaton Open class sounder VAD for addressable fire systems
Eaton's range of addressable EN 54-23 certified visual alarm devices (VAD's) brings its patented lens technology to its addressable fire systems for the first time.Featuring an ultra-low current draw, the range provides clear signalling in the event of an emergency providing the ultimate balance bet
Request a quoteDescription
Eaton's range of addressable EN 54-23 certified visual alarm devices (VAD's) brings its patented lens technology to its addressable fire systems for the first time.Featuring an ultra-low current draw, the range provides clear signalling in the event of an emergency providing the ultimate balance between cost and safety. Based on the successful LX range, the range boasts an impressively durable design that you can rely on.Across the range are a number of options to meet the demands of the application you are designing for including: indoor or outdoor including an IP66 option; wall or ceiling mounted and standalone or VAD sounder combination options.
Highlights
- Low current consumption: Increasing energy efficiency
- Loop connected: Volume and tones controlled by panel
- Compliant to EN54-23, 3 and 17: Suitable for the European fire market
Whats the difference between open class and wall / ceiling VAD classifications?
Open class visual alarm devices do not conform to either the wall or ceiling category, with the main difference being the coverage volume is specified by the manufacturer not the standard. Nevertheless, open class VAD's do still need to meet the 0.4 lux illumination requirement. The benefit being that mounting height is not restricted.
Designed to alert; whatever the weather
Specifying for an indoor application that is a washdown area such as in kitchens and warehouses or for outdoor applications? Choose Eaton's IP66 rated weatherproof option and it will alert; whatever the weather.
Clear visual notification during an emergency; approved to EN54-23
VADs provide a clear signal of evacuation for any occupant that may not be alerted by an audible alarm due to working in a noisy environment like a factory, because they are hard of hearing or increasingly in office and educational environments due to wearing headphones.
PRODUCT CODES
- Open Class Sounder VAD | CASB393
- Weatherproof Open Class Sounder VAD | CASB393WP
Additional technical details
- Total Loop Resistance for correct operation of short circuit isolator: 50Ω (max)
- Parallel Fault Resistance to be seen at the Control Panel for isolators to open: 200Ω (typ)
- Voltage at which isolator changes from open to closed or closed to open state: 3.8V to 11V
Product family: specifications and ordering options vary by model. Refer to the model details and official documentation.
Technical Specifications
| Beacon | 0.5Hz Flash |
|---|---|
| Cable Size / Type | 0.5mm - 2.5mm / FIRETUF, FP 200 or MICC |
| Compliance | EN54-3 Fire Alarm Device - Sounder EN54-17: 2005 EN54-23: 2010 Fire Alarm Device VAD |
| Continuous Current allowance through isolator | 700mA (max) |
| Environment Category | Type A - CASB393 Type B - CASB393WP |
| Isolator Resistance in closed state | 0.26Ω (max) |
| Leakage Current into direct short circuit with isolator open | 14mA (max) |
| Manufacturer highlight: Compliant to EN54-23, 3 and 17 | Suitable for the European fire market |
| Manufacturer highlight: Loop connected | Volume and tones controlled by panel |
| Manufacturer highlight: Low current consumption | Increasing energy efficiency |
| Maximum switching current of isolator | 1.5A |
| Operating Temperature | -10°C to +55°C |
| Sound Output @ +/-3dB (set by panel) | Low Volume: 87dB @ <8.6mA Medium Volume: 93dB @ <10mA High Volume: 100dB @ <11mA |
| Standby Current | <450μA |
| Supply Voltage | 19-30Vdc |
| Tones (set by panel) | Continuous 984Hz Pulsed 984 / 0Hz pulse 1Hz* Two Tone 644 / 984Hz @1 Hz cycle Slow Whoop 500-1200 Hz in 3.5 seconds / 0.5 seconds gap |
Documents & Technical Downloads
Catalogo Sistemas de Detecção e alarme de Incendio Endereçávei
Catalogues · pt
Fire systems - Product Catalogue
Catalogues · en
Fire systems - Product catalogue (Cooper)
Catalogues · en
Fire systems - Product catalogue (JSB)
Catalogues · en
Fire systems - Product catalogue (Menvier)
Catalogues · en
Addressable open class VAD - Certificate of constancy of performance
Certification reports
Addressable open class VAD - Certificate of constancy of performance
Certification reports
Addressable open class VAD - Declaration of performance
Certification reports · en
Addressable open class VAD - Declaration of performance
Certification reports · en
DECLARATION OF CONFORMITY
Certification reports
DECLARATION OF CONFORMITY
Certification reports
Fire installers mate - Fire systems and VADs design guide
Design guides
Visual alarm devices - Introduction to EN 54-23
Design guides
Addressable open class VAD - Installation manual
Installation instructions · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Fire systems - Compatibility guide
Product specification guides · en
Eaton Life Safety products - Reference book
Success stories · en
CASB393(WP) & CASB393(WP)-VSR - Technical data sheet
Technical data sheets
CASB393(WP) & CASB393(WP)-VSR - Technical data sheet
Technical data sheets
FXN559LPS(WP) - Technical data sheet
Technical data sheets
MASB880(WP) - Technical data sheet
Technical data sheets
Fire system and devices - Extended warranty-policy and terms
Warranty guides




